A. Slopes. The faces of cut and fill slopes shall be prepared and maintained to control erosion. This control shall consist of jute netting, effective planting, erosion control blankets, soil stabilizers, or other means, as approved by the City Engineer. Erosion control for slopes shall be installed as soon as practicable and prior to calling for final inspection. Exception: Erosion control measures need not be provided on cut slopes not subject to erosion due to the erosion-resistant character of the materials, as approved by the project consultants, to the satisfaction of the City Engineer. B. Other Devices. Where necessary, check dams, cribbing, riprap, or other devices or methods shall be employed to control any erosion. Also, jute netting shall be immediately installed on any slopes having a vertical height of seven (7) feet or more and steeper than three to one (3:1) horizontal to vertical ratio (H:V) to minimize or control erosion problems. C. Erosion Control (Slopes Subject to Section 17.51.020). Erosion control for grading where average slopes are greater than ten percent (10%) and involving more than one hundred (100) cubic yards is subject to Section 17.51.020 (Hillside Development). For specific recommendations for phasing the project to promote prompt revegetation, leaving undeveloped pads longer than thirty (30) to ninety (90) days and clearing of brush or vegetation, refer to the Hillside Development Guidelines. D. Planting (Areas Not Subject to Section 17.51.020). The surface of all cut slopes more than five (5) feet in height and fill slopes more than three (3) feet in height shall be protected against damage by erosion by planting with grass or ground cover plants. Slopes exceeding five (5) feet in vertical height shall also be planted with one (1) gallon minimum sized shrubs, spaces at not to exceed ten (10) feet on centers; and fifteen (15) gallon minimum sized trees, spaced not to exceed twenty (20) feet on centers; or a combination of shrubs and trees at equivalent spacings, in addition to the grass or ground cover plants to the satisfaction of the Director. The plants selected and planting methods used shall be suitable for the soil and climatic conditions of the site. Plant material shall be selected which will produce a coverage of permanent planting to effectively control erosion. Consideration shall be given to deep rooted plant material needing limited watering, maintenance, high root to shoot ratio, wind susceptibility, and fire-retardant characteristics. All plant materials must be approved by the Director. Planting may be modified for the site if specific recommendations are provided by both the geotechnical engineer and a landscape architect. Specific recommendations must consider soils and climatic conditions, irrigation requirements, planting methods, fire retardant characteristics, water efficiency, maintenance needs, and other regulatory requirements. Recommendations must include a finding that the alternative planting will provide a permanent and effective method of erosion control. Modifications to planting must be approved by the Director prior to installation. E. Irrigation. Slopes required to be planted by subsection (D) of this section shall be provided with an approved system of irrigation that is designed to cover all portions of the slope. Irrigation system plans shall be submitted to and approved by the Director prior to installation. A functional test of the system may be required. For slopes less than twenty (20) feet in vertical height, hose bibs to permit hand watering will be acceptable if such hose bibs are installed at conveniently accessible locations where a hose no longer than fifty (50) feet is necessary for irrigation. Irrigation requirements may be modified for the site if specific recommendations are provided by both the geotechnical engineer and a landscape architect. Specific recommendations must consider soils and climatic conditions, irrigation requirements, planting types, planting methods, fire retardant characteristics, water efficiency, maintenance needs, and other regulatory requirements. Recommendations must include a finding that the alternative irrigation method will sustain the proposed planting and provide a permanent and effective method of erosion control. Modifications for irrigation systems must be approved by the Director prior to installation. F. Planting and Irrigation (Areas Subject to Section 17.51.020). Requirements for planting and irrigation in areas subject to Chapter 17.51.020 (Hillside Development) are governed by that ordinance. Recommendations for these areas are also included in the Hillside Development Guidelines. Plant material shall be selected which will produce a coverage of permanent planting effectively controlling erosion. Consideration shall be given to deep-rooted plant material needing limited watering, to low maintenance during the lifetime of the project, to high root to shoot ratio (weight of above-ground parts versus root system), wind susceptibility and fire-retardant characteristics. G. Plans and Specifications. Planting and irrigation plans shall be submitted for slopes required to be planted and irrigated by subsections (D) and (E) of this section. Except as waived by the City Engineer for minor grading, the plans for slopes twenty (20) feet or more in vertical height shall be prepared and signed by a civil engineer or landscape architect. These plans must be approved by the City prior to issuance of the grading permit unless other provisions are made to the satisfaction of the City Engineer. The responsibility of maintenance of drainage terrace shall be clearly stated on the grading plan to the satisfaction of the City Engineer. H. Rodent Control. Fill slopes shall be protected from potential slope damage by a preventative program of rodent control. I. Release of Security. The planting and irrigation systems required by this section shall be installed as soon as practical after rough grading. Prior to final approval of grading and before the release of the grading security, the planting shall be well established and growing on the slopes and there shall be evidence of an effective rodent control program. J. Graded and/or landscaped areas within a landscape maintenance district are to be maintained in accordance with the original landscape plans and design concept per the originally approved subdivision or development plans. Any alteration of landscape plans or of areas within a landscape maintenance district must be approved by the Director of Administrative Services per the regular provisions of the grading code. Homeowner encroachments such as fences, block walls, structures, unauthorized plantings, alterations to the irrigation, grading or drainage are not allowed. Any approved alterations must be done by City-authorized crews through an approved City permit. Failure to comply with this section shall constitute a use of land contrary to the provisions of this title and shall be deemed a public nuisance under Title 23.
( Ord. 13-8 § 4 (Exh. A), 6/11/2013 )
Ask a question about Santa Clarita law
Corpus searches the Santa Clarita sections it holds and shows the ones that match, with their citations. Free, no sign-in.