§ 17.95.220 — Alternative Compliance—Technical Infeasibility
Municipal Code, City of Santa Clarita, California (Santa Clarita Municipal Code current through legislation adopted 09-08-2026 (eCode360 publication SA4627, scraped 2026-11-18)) · Santa Clarita Municipal Code § 17.95.220
Corpus is an independent public-information project, not the official City of Santa Clarita website. Stable reference: corpuslaw.us/code/e268f341-0849-4acf-9a3b-b2041d92a48f
§ 17.95.220: Alternative Compliance—Technical Infeasibility.
When, as determined by the City Engineer or his/her appointee, one hundred percent (100%) on-site retention of the SWQDv is technically infeasible, partially or fully, the infeasibility shall be demonstrated in the submitted LID plan. The technical infeasibility may result from conditions that may include, but are not limited to: A. The infiltration rate of saturated in-situ soils is less than three-tenths (0.3) inch per hour, and it is not technically feasible to amend the in-situ soils to attain an infiltration rate necessary to achieve reliable performance of infiltration or bioretention BMPs in retaining the SWQDv on site; B. Locations where seasonal high groundwater is within five (5) to ten (10) feet of surface grade; C. Locations within one hundred (100) feet of a groundwater well used for drinking water; D. Brownfield development sites or other locations where pollutant mobilization is a documented concern; E. Locations with potential geotechnical hazard; F. Smart growth and infill or redevelopment locations, where the density and/or nature of the project would create significant difficulty for compliance with the on-site volume retention requirement. If partial or complete on-site retention is technically infeasible, the project site may biofiltrate one and one-half (1.5) times the portion of the remaining SWQDv that is not reliably retained on site. Biofiltration BMPs must adhere to the design specifications provided in the municipal NPDES permit. 1. Additional alternative compliance options, such as off-site infiltration, may be available to the project site. The project site should contact the City Engineer or his/her appointee to determine eligibility. Alternative compliance options are further specified in the Los Angeles County 2014 Low Impact Development Standards Manual (2014 LID Standards Manual). G. The remaining SWQDv that cannot be retained or biofiltered on site must be treated to reduce pollutant loading. BMPs must be selected and designed to meet pollutant-specific benchmarks as required per the municipal NPDES permit. Flow-through BMPs may be used to treat the remaining SWQDv and must be sized based on a rainfall intensity of: 1. Two-tenths (0.2) inches per hour, or 2. The one (1) year, one (1) hour rainfall intensity as determined from the most recent Los Angeles County isohyetal map, whichever is greater. H. A multi-phased project may comply with the standards and requirements of this section for all of its phases by: (1) designing a system acceptable to the City Engineer to satisfy these standards and requirements for the entire site during the first phase, and (2) implementing these standards and requirements for each phase of development or redevelopment of the site during the first phase or prior to commencement of construction of a later phase, to the extent necessary to treat the stormwater from such later phase. For purposes of this section, "multi-phased project" shall mean any planning priority project implemented over more than one (1) phase and the site of a multi-phased project shall include any land and water area designed and used to store, treat, or manage stormwater runoff in connection with the development or redevelopment, including any tracts, lots, or parcels of real property, whether developed or not, associated with, functionally connected to, or under common ownership or control with such development or redevelopment. (Source: Order No. R4-2012-0175.)
( Ord. 13-8 § 4 (Exh. A), 6/11/2013 ; Ord. 15-4 § 1, 5/26/2015 )
Ask a question about Santa Clarita law
Corpus searches the Santa Clarita sections it holds and shows the ones that match, with their citations. Free, no sign-in.