§ 18.04.060 — Section 1613.12 is Added
Municipal Code, City of Santa Clarita, California (Santa Clarita Municipal Code current through legislation adopted 09-08-2026 (eCode360 publication SA4627, scraped 2026-11-18)) · Santa Clarita Municipal Code § 18.04.060
Corpus is an independent public-information project, not the official City of Santa Clarita website. Stable reference: corpuslaw.us/code/2a4ae0d7-7a9b-46bb-b336-04994b5136ef
§ 18.04.060: Section 1613.12 is Added.
Section 1613.12 is added as follows: 1613.12 Light-gage mudsill anchors. Light-gage mudsill anchors which are intended to be bent upon installation shall not be used to anchor shear walls. Where light-gage anchors are used at exterior walls not designed as shear walls, they shall be fully protected by the exterior weather barrier assembly or by an approved corrosion-resistant coating.
( Ord. 25-5 , 11/25/2025 )