§ 18.12.070 — Section R306.2.1 is Amended
Municipal Code, City of Santa Clarita, California (Santa Clarita Municipal Code current through legislation adopted 09-08-2026 (eCode360 publication SA4627, scraped 2026-11-18)) · Santa Clarita Municipal Code § 18.12.070
Corpus is an independent public-information project, not the official City of Santa Clarita website. Stable reference: corpuslaw.us/code/a69ac8ee-f9d4-4565-b85d-a07bce856afd
§ 18.12.070: Section R306.2.1 is Amended.
Section R306.2.1 is amended as follows: Condition 1 is amended as follows: 1. Buildings and structures in flood hazard areas shall have the lowest floors elevated to the base flood elevation plus 1 foot. Condition 3 is amended as follows: 3. Basement floors that are below grade on all sides shall be elevated to the base flood elevation plus 1 foot. Exception is amended as follows: Exception: Enclosed areas below the design flood elevation shall meet the requirements of Section R306.2.2
( Ord. 25-5 , 11/25/2025 )
Ask a question about Santa Clarita law
Corpus searches the Santa Clarita sections it holds and shows the ones that match, with their citations. Free, no sign-in.