§ 18.13.030 — Section R403.1.3.4 is Amended
Municipal Code, City of Santa Clarita, California (Santa Clarita Municipal Code current through legislation adopted 09-08-2026 (eCode360 publication SA4627, scraped 2026-11-18)) · Santa Clarita Municipal Code § 18.13.030
Corpus is an independent public-information project, not the official City of Santa Clarita website. Stable reference: corpuslaw.us/code/56d14f75-e31f-4ea5-8d47-5f3f1a86a5fe
§ 18.13.030: Section R403.1.3.4 is Amended.
Section R403.1.3.4 is amended to read as follows: R403.1.3.4 Interior bearing and braced wall panel footings in Seismic Design Categories D0, D1 and D2. Where a geotechnical report is not provided and the presence of expansive soils is unknown, the minimum depth of footings shall be 18 inches (458 mm) for interior bearing and braced walls. Such footings shall be reinforced with a minimum of two #4 rebar at the top and two #4 rebar at the bottom. Exception: The minimum footing depth for unoccupied Group U structures or patio structures accessory to a Group R-3 occupancy shall be 12 inches (305 mm). Otherwise, the minimum depth of footings below the undisturbed ground surface shall be 12 inches (305 mm).
( Ord. 25-5 , 11/25/2025 )
Ask a question about Santa Clarita law
Corpus searches the Santa Clarita sections it holds and shows the ones that match, with their citations. Free, no sign-in.