§ 25.03.060 — Eligibility Checklist
Municipal Code, City of Santa Clarita, California (Santa Clarita Municipal Code current through legislation adopted 09-08-2026 (eCode360 publication SA4627, scraped 2026-11-18)) · Santa Clarita Municipal Code § 25.03.060
Corpus is an independent public-information project, not the official City of Santa Clarita website. Stable reference: corpuslaw.us/code/b75d38c7-4f85-4d5a-958b-2c19f6bc4f01
§ 25.03.060: Eligibility Checklist.
A. To be eligible for expedited solar photovoltaic (PV) permitting a small residential rooftop solar energy system must comply with all of the following requirements: 1. General Requirements. a. The system size is ten (10) kW AC CEC rating or less. b. The solar array is roof-mounted on a single or duplex family dwelling or accessory structure. c. The solar panel/module arrays will not exceed the maximum legal building height. d. The solar system is utility interactive and without battery storage. e. A completed application for a permit from the City of Santa Clarita is attached with the required documentation. 2. Electrical Requirements. a. No more than four (4) PV module strings are connected to each maximum power point tracking (MPPT) input where source circuit fusing is included in the inverter. b. No more than two (2) strings per MPPT input where source circuit fusing is not included in the inverter. c. Fuses (if needed) are rated to the series fuse rating of the PV module. d. No more than one (1) noninverter-integrated DC combiner is utilized per inverter. e. For central inverter systems, no more than two (2) inverters are utilized. f. The PV system is interconnected to a single-phase AC service panel of nominal one hundred twenty/two hundred twenty (120/220) Vac with a bus bar rating of two hundred twenty-five (225) A or less. g. The PV system is connected to the load side of the utility distribution equipment. h. A solar PV standard plan and supporting documentation is completed and attached to the application. 3. Structural Requirements. The applicant has verified through the use of standard engineering evaluation techniques that the support structure for the small residential rooftop solar energy system is stable and adequate to transfer all wind, seismic, dead, and live loads associated with the system to the roof and building structure and foundation. Supporting documentation is available if requested. 4. Fire Safety Requirements. a. Clear access pathways are provided and shown on the roof plan around the rooftop system in accordance with Los Angeles County Fire Department requirements. b. The fire classification of the solar system meets the requirements for a Class "B" roof or, if located in the City's Fire Zone, the requirements for a Class "A" roof. c. Any new roofing installed shall meet or exceed the existing roof's fire safety classification for Class "A" or Class "B" materials. d. A note must be shown on the plans that all required markings and labels will be provided to the building inspector in the field. e. A diagram of the roof layout of all panels, modules, clear access pathways, and approximate locations of electrical disconnecting means and roof access points is completed and attached.
( Ord. 17-12 § 1, 9/12/2017 )
Ask a question about Santa Clarita law
Corpus searches the Santa Clarita sections it holds and shows the ones that match, with their citations. Free, no sign-in.
