§ 14-30.050 — Irrigation design plan
Code of Ordinances, City of Santa Rosa, California (Code 2026-09-15: eCode360 publication current through Ord. No. 2026-014 adopted September 15, 2026 (scraped 2026-11-20)) · Santa Rosa Code of Ordinances § 14-30.050
Corpus is an independent public-information project, not the official City of Santa Rosa website. Stable reference: corpuslaw.us/code/7128567c-7bfd-41dc-86f5-42edf5da9901
§ 14-30.050: Irrigation design plan.
(A) The irrigation design plan, at a minimum, shall contain: (1) Location and size of separate water meters for landscape; (2) Location and size of irrigation system point of connection; (3) Location, type and size of all components of the irrigation system, including controllers, main and lateral lines, master valves, valves, sprinkler heads and other application devices, moisture sensing devices, rain sensors, check valves, quick couplers, flow sensors, pressure regulators, and backflow prevention devices; (4) Static water pressure at the point of connection to the public water supply; (5) Flow rate (gallons per minute), application rate (inches per hour), and design operating pressure (pressure per square inch) for each station; (6) Location of recycled water irrigation systems, if applicable; (7) The Hydrozone Table; (8) The following statement: "I have complied with the criteria of the ordinance and applied them accordingly for the efficient use of water in the irrigation design plan"; and (9) The signature of a licensed landscape architect, certified irrigation designer, licensed landscape contractor, or any other person authorized to design an irrigation system. (See Sections 185500.1, 5615, 5641, 5641.1, 5641.2, 5641.3, 5641.4, 5641.5, 5641.6, 6701, 7027.5 of the Business and Professions Code, Section 832.27 of Title 16 of the California Code of Regulations, and Section 6721 of the Food and Agricultural Code.) (B) For each landscape project subject to this chapter applicants shall submit an irrigation design plan that is designed and installed to meet irrigation efficiency criteria as described in the maximum applied water allowance (MAWA) and in accordance with the following: (1) Dedicated irrigation meter or submeter must be specified. (2) Landscapes of 5,000 square feet or larger require a high-flow sensor that can detect high flow conditions and have the capabilities to shut off the system. (3) Master shut-off valves are required on all projects of 5,000 square feet or larger except landscapes that make use of technologies that allow for the individual control of sprinklers that are individually pressurized in a system equipped with low pressure shut down features. (4) Isolation valves shall be installed at the point of connection and before each valve or valve manifold. (5) Weather-based or other sensor based self-adjusting irrigation controllers utilizing non-volatile memory shall be required. (6) Rain sensors shall be installed for each irrigation controller. (7) Pressure regulation and/or booster pumps shall be installed so that all components of the irrigation system operate at the manufacturer's recommended optimal pressure. (8) Irrigation system shall be designed to prevent runoff or overspray onto nontargeted areas. (9) Relevant information from the soil analysis report, such as soil type and infiltration rate, shall be utilized when designing irrigation systems. (10) The design of the irrigation system shall conform to the hydrozones of the landscape design plan. (11) All irrigation emission devices must meet the requirements set in the American National Standards Institute (ANSI) standard, American Society of Agricultural and Biological Engineers'/International Code Council's (ASA-BE/ICC) 802-2014 "Landscape Irrigation Sprinkler and Emitter Standard." All sprinkler heads installed in the landscape must document a distribution uniformity low quarter of 0.65 or higher using the protocol defined in ASABE/ICC 802-2014. (12) Point source irrigation is required where plant height at maturity will affect the uniformity of an overhead system. (13) Minimum 24-inch setback of overhead irrigation is required where turf is directly adjacent to a continuous hardscape that flows into the curb and gutter. (14) Slopes greater than 15 percent shall be irrigated with point source or other low-volume irrigation technology. (15) A single valve shall not irrigate hydrozones that mix high water use plants with moderate, low, or very low water use plants. (16) Trees shall be placed on separate valves except when planted in turf areas. (17) Sprinkler heads, rotors and other emission devices on a valve shall have matched precipitation rates. (18) Head to head coverage is required unless otherwise directed by the manufacturer's specifications. (19) Swing joints or other riser protection components are required on all risers. (20) Check valves shall be installed to prevent low-head drainage.
( Ord. 3925 § 1, 2010 ; Ord. 4051 § 5, 2015 )
Ask a question about Santa Rosa law
Corpus searches the Santa Rosa sections it holds and shows the ones that match, with their citations. Free, no sign-in.