For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15-08.490 — Periodic compliance reports

Code of Ordinances, City of Santa Rosa, California (Code 2026-09-15: eCode360 publication current through Ord. No. 2026-014 adopted September 15, 2026 (scraped 2026-11-20)) · Santa Rosa Code of Ordinances § 15-08.490

Corpus is an independent public-information project, not the official City of Santa Rosa website. Stable reference: corpuslaw.us/code/4c3d1bef-01cf-4736-b2d9-3d020300490d

§ 15-08.490: Periodic compliance reports.

(A) All significant industrial users shall, unless the Control Authority/City performs the IUs sampling and meter reads, submit a report no less than twice per year, indicating the nature and concentration of pollutants in the discharge which are limited by pretreatment standards or requirements and the measured or estimated average and maximum daily flows for the reporting period. All periodic compliance reports shall be signed and certified in accordance with 40 CFR Part 403.6(a)(2)(ii) or as amended. The report shall contain a description of the methods utilized by the user in collecting the wastewater sample for analysis, including, but not limited to, the sampling device(s) used, the sampling period, the amount of each sample collected, sample handling and preservation techniques used, and date of sample delivery to the laboratory for analysis. (B) All wastewater samples must be representative of the user's discharge. Wastewater monitoring and flow measurement facilities will be properly operated, cleaned, calibrated, and maintained in good working order at all times. The failure of a user to keep its monitoring facility in good working order is a violation and shall not be grounds for the user to claim that sample results are unrepresentative of its discharge. (C) If a user, subject to the reporting requirement in this section, monitors any pollutant more frequently than required by the Director of Utilities, using the procedures prescribed in this title, the results of this monitoring will be included in the report. (D) In the event a sample from a periodic compliance report indicates that a constituent is in violation of the allowable concentration levels as set forth in the user's permit or permit contract, the user shall inform the City within the next business day, repeat the sampling and pollutant analysis for the parameter in violation, and submit in writing the results of this second analysis within 30 days of the discovery of the first violation. The initial sampling and analysis report shall be submitted within 45 days of the initial sampling date with a cover report setting forth the causes of the violation, the remedial actions taken to date with regard to the violation, and the scheduled additional actions which will be implemented to prevent a recurrence. (E) The Director of Utilities may also, at any time, require a signed statement by the user setting forth management practices and/or material usage practices which have an effect on the nature, volume, and quality of the wastewater discharge and/or which potentially will affect the ability to comply with pretreatment standard requirements. (F) When required by the Director of Utilities, an industrial user shall submit a report indicating the concentration of specific pollutants discharged in the effluent. The determination of said pollutants by the Director of Utilities shall be based on what is reasonably expected to be found at the site and the frequency of monitoring shall be based on the compliance status of the industrial user. (G) Periodic compliance reports may be waived by the Director of Utilities if the City is monitoring the user discharge.

( Ord. 3895 § 3, 2008 ; Ord. 2019-016 § 11 ; Ord. 2025-002 , 2/4/2025 )

Ask a question about Santa Rosa law

Corpus searches the Santa Rosa sections it holds and shows the ones that match, with their citations. Free, no sign-in.