§ 18-48.040 — Scope of evaluation and rehabilitation
Code of Ordinances, City of Santa Rosa, California (Code 2026-09-15: eCode360 publication current through Ord. No. 2026-014 adopted September 15, 2026 (scraped 2026-11-20)) · Santa Rosa Code of Ordinances § 18-48.040
Corpus is an independent public-information project, not the official City of Santa Rosa website. Stable reference: corpuslaw.us/code/63ff62f7-17ee-4061-b3ea-2963226489e5
§ 18-48.040: Scope of evaluation and rehabilitation.
18-48.040.1 Evaluation and rehabilitation. When a seismic evaluation is required by Section 18-48.030.1, the building owner or authorized representative shall retain a design professional, licensed in the State of California, to evaluate the building and building elements in accordance with one of the standards listed in Section 18-48.050.1 and this section. Rehabilitation and/or demolition of all deficient buildings and building elements is required in accordance with the evaluation of the licensed design professional and this chapter. The licensed design professional shall submit a written evaluation report to the Authority Having Jurisdiction which shall include, but not be limited to, the items listed in Sections 18-48.040.1.1 through 18-48.040.1.3. Unknown building elements shall be verified or otherwise addressed by the design professional retained. 18-48.040.1.1 Scope and intent. The purpose of the evaluation, a summary of the evaluation procedure(s), and the level of investigation conducted. 18-48.040.1.2 Design standard criteria. The seismic evaluation standard/criteria used, and the building performance objective chosen (minimum of life safety). 18-48.040.1.3 Site and building data. Site and building data shall include, but not be limited to, all items listed in Sections 18-48.040.1.3.1 through 18-48.040.1.3.14. 18-48.040.1.3.1 General building description. Building address, assessor's parcel number, year built, design standard/code in effect at time of original permit application, number of stories, story height, building height, building dimensions, approximate floor area, occupancy class, type of construction, historical significance, and building type. 18-48.040.1.3.2 Structural systems description. Framing, seismic-force-resisting-systems, floor and roof diaphragm construction, basement, and foundation systems. Copies of the original construction drawings shall be submitted if available. 18-48.040.1.3.3 Diaphragm chords. Diaphragm chord continuity, strength, and connections to the diaphragm web and vertical elements of the lateral force resisting system. 18-48.040.1.3.4 Diaphragm collectors. Diaphragm collector continuity, strength, and connections to the diaphragm web and vertical elements of the lateral force resisting system. 18-48.040.1.3.5 Diaphragm ties. Diaphragm tie continuity, strength, and connection to the diaphragm web elements. 18-48.040.1.3.6 Wall anchorage. Out-of-plane wall anchorage to diaphragms. 18-48.040.1.3.7 Wall strength. Out-of-plane strength of walls. 18-48.040.1.3.8 Seismic separation or interconnection. Separation and/or interconnection of adjacent buildings sharing common vertical or seismic-force-resisting elements. 18-48.040.1.3.9 Nonstructural systems description. All nonstructural elements that affect the seismic performance of the building, or whose failure could cause serious life-threatening injuries to occupants or persons near the building. 18-48.040.1.3.10 General site information. Site soil factors, soil type, seismic design category, level of seismicity, spectral response acceleration parameters, and soil site class (buildings within risk categories I or II may assume soil site class D unless site-specific geotechnical information is available). 18-48.040.1.3.11 Supplemental documentation. Photographs of the building exterior and structural elements, general condition of the structure, special features of the building, and any general comments that pertain to life safety or structural stability. Preliminary structural calculations, material test results, all necessary checklists, and summary data sheets. 18-48.040.1.3.12 General findings. A list of observed defects including cracks, uncleanliness, evidence of leaks, foundation settlement, sagging floors, rusting metal, rotting wood, and general deterioration of any other building material used. 18-48.040.1.3.13 Seismic findings. A list of seismic deficiencies identified during the inspection and/or evaluation of the structure. 18-48.040.1.3.14 Recommendations. Mitigation solutions and/or recommendations for further evaluation. Exceptions to Section 18-48.040.1.3: 1. | In lieu of the information required by Section 18-48.040.1.3, the design professional retained may submit documentation showing the building complies with the benchmark provisions of Sections 4.3.1 through 4.3.4 of ASCE 41-13. This exception does not include evaluations of buildings known to have neglected or inadequately addressed the applicable design standards in effect at the time of original building permit application. Review of the record drawings of the structure shall be performed to confirm that the primary elements of the seismic-force-resisting system and their detailing were designed in accordance with the applicable provisions listed in Table 4-6 of ASCE 41-13. This exception does not apply to nonstructural elements, and a written report in accordance with ASCE 41-13 Section 16.17 shall be required for all nonstructural building elements identified in Section 18-48.030.1, as applicable. 2. | In lieu of the information required by Section 18-48.040.1.3, the design professional retained may submit documentation showing the building complies with the Uniform Building Code, 1955 Edition, including earthquake provisions (applicable only to buildings built prior to 1958). Documentation shall include a review of the record drawings of the structure to confirm that the primary elements of the seismic-force-resisting system were designed and detailed in accordance with applicable seismic provisions. This exception does not apply to nonstructural elements, and a written report in accordance with ASCE 41-13 Section 16.17 shall be required for all nonstructural building elements identified in Section 18-48.030.1, as applicable. 3. | As approved by the building official on a case-by-case basis, the design professional retained may submit documentation including all items specified in Exceptions 18-48.040.1.3a through 18-48.040.1.3c below in lieu of the information required by Section 18-48.040.1.3. (Structures and buildings larger than 10,000 square feet may have additional requirements). 3a. | One or more completed Tier 1 Checklists, as required by Table 4-7 of ASCE 41-13 (Life Safety Performance Level), including Quick Checks for Strength and Stiffness per Section 4.5.3 of ASCE 41-13. 3b. | A completed Summary Data Sheet found in Appendix C of ASCE 41-13 (Life Safety Performance Level). 3c. | An evaluation of diaphragms, chords, collectors, ties, and wall anchorage per Sections 7.2.9 through 7.2.11.2 of ASCE 41-13. Alternate: An evaluation of diaphragms, chords, collectors, ties, and wall anchorage per sections 12.10 and 12.11 of ASCE 7-16, with a design spectral response acceleration parameter at short periods (SDS) determined per section 12.8.1.3 of ASCE 7-16.
( Ord. 2022-015 § 13 )
Ask a question about Santa Rosa law
Corpus searches the Santa Rosa sections it holds and shows the ones that match, with their citations. Free, no sign-in.