For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 20-22.050 — Residential district general development standards

Code of Ordinances, City of Santa Rosa, California (Code 2026-09-15: eCode360 publication current through Ord. No. 2026-014 adopted September 15, 2026 (scraped 2026-11-20)) · Santa Rosa Code of Ordinances § 20-22.050

Corpus is an independent public-information project, not the official City of Santa Rosa website. Stable reference: corpuslaw.us/code/cd55ee02-addb-4a95-9ca4-c236a9896826

§ 20-22.050: Residential district general development standards.

New land uses, structures, and site development, and alterations to existing land uses, structures, and site development within the residential zoning districts shall be designed, constructed, and established in compliance with the following re-quirements, and all applicable standards in Divisions 3 (Site Planning and General Development Standards) and 4 (Standards for Specific Land Uses) of this Zoning Code. A. RR and R-1 zoning districts. See the requirements in Tables 2-3 and 2-4. B. R-2 and R-3 zoning districts. See the requirements in Tables 2-3 and 2-5. C. MH zoning district. See the requirements in Section 20-42.100 (Mobile Home Parks). D. TV-R zoning district. See the requirements in Tables 2-3 and 2-5. The standards of this district are intended to support a diverse mix of multi-family housing, live-work housing and mixed-use residential with neighborhood serving retail. See also the General Plan, Downtown Station Area Specific Plan and Section 2 (Core Area) of the City's Design Guidelines. 1. Residential required. Each new development shall be a residential project, with a ground floor neighborhood serving retail or live-work component encouraged, in compliance with the residential density requirements of the TV zoning district in Table 2-3. 2. Height limit. There is a four-story height limit for new buildings within this zoning district, with the exception of those projects located adjacent to existing residential zones or residential uses where the maximum height shall transition down to a maximum of three stories adjacent to the residential property. 3. Development adjacent to residential zones and residential uses. Development located adjacent to a Residential zone or residential use shall be compatible in both scale and design with the adjacent neighborhood. 4. Site design, hours of operation. Site design and hours of operation shall be as determined by the review authority to be compatible with surrounding neighborhood uses. 5. Setbacks for noise and air quality impacts. To facilitate the planned transition to a more compact Development pattern within the TV-R zoning district, increased setback distances shall not be used as a measure to mitigate potential noise and air quality impacts when new development is proposed adjacent to nonconforming industrial or light industrial uses. E. NMU zoning district. See the requirements in Tables 2-6 and 2-8. The standards of this district allow for new multi-family residential development and other neighborhood-scale supporting uses in all-residential or mixed-use buildings. See also Sections 2 (Core Area), 3.1 (Single-Family Residential), 3.2 (Multiple-Family Residential), and 4.3 (Infill Development), of the City's Design Guidelines. TABLE 2-4—RR AND R-1 DISTRICT DEVELOPMENT STANDARDS Development Feature | Requirement by Zoning District RR-40 | RR-20 | R-1-6 | R-1-7.5 | R-1-9 | R-1-15 Setbacks, primary structures (1) | Minimum setbacks required. See Section 20-30.110 for setback measurement instructions, and exceptions to these requirements. Front | 20 ft | 20 ft | 15 ft | 20 ft | 20 ft | 20 ft Side—Interior | 5 ft | 5 ft | 5 ft for 1-story parts of structures10 ft for 2-story parts of structures | 5 ft for 1-story parts of structures10 ft for 2-story parts of structures | 10 ft | 10 ft Side—Corner | 20 ft | 15 ft | 15 ft | 15 ft | 15 ft | 15 ft Rear | 20 ft | 20 ft | 15 ft | 15 ft | 20 ft | 20 ft Garage/carport front | A garage/carport entrance facing a public or private street shall be set back 19 ft from the rear of the sidewalk, street property line, or street plan line, whichever is greater. A garage facing a public or private alley or driveway shall be set back 3 to 5 ft from the alley property line, back of curb, sidewalk, or pavement edge, whichever is greater. Setbacks, accessory structures (1) | Minimum setbacks accessory structures. See also Sections 20-30.110 for exceptions, and 20-42.030 (Accessory Uses and Structures). Front | 20 ft Side—Interior | 5 ft | 5 ft0 ft for attached and zero lot line units | 5 ft0 ft for attached and zero lot line units Side—Corner | 20 ft | 15 ft Rear | 5 ft | 5 ft Alley | 3 to 5 ft, or 19 ft when used for parking with direct access to alley. Building separation | See Sections 20-30.110 (Setback Requirements and Exceptions) and 20-42.030 (Accessory Structures and Uses). Lot coverage | Maximum percentage of total lot area that may be covered by structures. See Section 20-22.040 (Residential District Subdivision and Density Standards). Residential structures | 40% Meeting facility | Determined through Conditional Use Permit approval, to a maximum of 75% Height limit | Maximum allowable height of structures. See Sections 20-30.070 (Height Limits and Exceptions) for height measurement requirement and height limit exception and 20-52.060 (Minor Adjustments, Minor Variances and Variances). Primary structures | 35 ft | 35 ft Accessory structures | 16 ft | 16 ft Fences, walls & hedges | No fence, wall, or hedge shall exceed a height of 3 feet in any required front or corner side setback, or 6 feet in any other location on the lot. See Section 20-30.050 (Fences, Walls, and Hedges). Landscaping | See Chapter 20-34 (Landscaping Standards). Parking | See Chapter 20-36 (Parking and Loading). Signs | See Chapter 20-38 (Signs). Notes: (1) | For a multi-family housing project the setbacks are measured from the exterior walls of the structure to the outermost project property lines. TABLE 2-5—R-2 AND R-3 DISTRICT DEVELOPMENT STANDARDS Development Feature | Requirement by Zoning District R-2 | R-3-10 | R-3-15 | R-3-18 | R-3-30 | R-3-HD | TV-R Setbacks, primary structures (1) (2) | Minimum setbacks required. See Section 20-30.110 for setback measurement instructions, and exceptions to these requirements. Front | 10 ft (3) | 10 ft (3) | 10 ft (3) | 10 ft (3) | 10 ft (3) | 10 ft (3) | None, except as required by the review authority (2) Side—Interior 1-story portions Attached and detached except when: | 5 ft | 5 ft | 5 ft | 5 ft | 5 ft | 5 ft | None, except as required by the review authority (2) Abutting an R-3 | 0 ft | 0 ft | 0 ft | 0 ft | 0 ft | 0 ft Side—Interior 2-story portions Attached and detached except when: | 10 ft | 10 ft | 10 ft | 10 ft | 10 ft | 10 ft | None, except as required by the review authority (2) Abutting an R-3 | 7.5 ft | 0 ft | 0 ft | 0 ft | 0 ft | 0 ft Abutting a nonresidential district | 7.5 ft | 7.5 ft | 7.5 ft | 7.5 ft | 7.5 ft | 7.5 ft Side—Interior 3-story portions (or more) Attached and detached except when: | 15 ft | 15 ft | 15 ft | 15 ft | 15 ft | 15 ft | None, except as required by the review authority (2) Abutting an R-3 | 10 ft | 0 ft | 0 ft | 0 ft | 0 ft | 0 ft Abutting a nonresidential district | 10 ft | 10 ft | 10 ft | 10 ft | 10 ft | 10 ft Side—Corner | 10 ft (3) | 10 ft (3) | 10 ft (3) | 10 ft (3) | 10 ft (3) | 10 ft (3) Rear Attached and detached except when: | 15 ft | 15 ft | 15 ft | 15 ft | 15 ft | 15 ft | None, except as required by the review authority (2) Abutting an R-3 | 15 ft | 0 ft | 0 ft | 0 ft | 0 ft | 0 ft Garage/carport front | A garage/carport entrance facing a public or private street shall be set back 19 ft from the rear of the sidewalk, street property line, or street plan line, whichever is greater. A garage facing a public or private alley or driveway shall be set back 3 to 5 ft, or 19 ft from the alley property line, back of curb, sidewalk, or pavement edge, whichever is greater. Setbacks, accessory structures (1) | Minimum setbacks for accessory structures. See also Sections 20-30.110 for exceptions, and 20-42.030 (Accessory Uses and Structures). Front | 20 ft | 20 ft | 20 ft | 20 ft | 20 ft | 20 ft | None, except as required by the review authority (2) Side—Interior | 5 ft | 5 ft | 5 ft | 5 ft | 5 ft | 5 ft Side—Corner | 15 ft | 15 ft | 15 ft | 15 ft | 15 ft | 15 ft Rear | 5 ft | 5 ft | 5 ft | 5 ft | 5 ft | 5 ft Alley | 3 to 5 ft, or 19 ft when used for parking with direct access to alley. | 3 to 5 ft, or 19 ft when used for parking with direct access to alley. | 3 to 5 ft, or 19 ft when used for parking with direct access to alley. | 3 to 5 ft, or 19 ft when used for parking with direct access to alley. | 3 to 5 ft, or 19 ft when used for parking with direct access to alley. | 3 to 5 ft, or 19 ft when used for parking with direct access to alley. | 3 to 5 ft, or 19 ft when used for parking with direct access to alley. Building separation | See Sections 20-30.110 (Setback Requirements and Exceptions) and 20-42.030 (Accessory Structures and Uses). Lot coverage | Maximum percentage of total lot area that may be covered by structures. See Section 20-22.040 (Residential District Subdivision and Density Standards). Maximum coverage | 50% | 55% | 60% | 65% | 75% | 75% | 100% Height limit | Maximum allowable height of structures. See Section 20-30.070 (Height Limits and Exceptions) for height measurement requirements, and height limit exceptions. Primary structures | 35 ft | 35 ft | 35 ft | 45 ft | 45 ft | 45 ft | 4 stories (4) Accessory structures | 16 ft | 16 ft | 16 ft | 16 ft | 16 ft | 16 ft | 16 ft Fences, walls & hedges | No fence, wall, or hedge shall exceed a height of 3 feet in any required front or corner side setback, or 6 feet in any other location on the lot. See Section 20-30.110 (Setback requirements and exceptions). Landscaping | See Chapter 20-34 (Landscaping Standards). Parking | See Chapter 20-36 (Parking and Loading). Signs | See Chapter 20-38 (Signs). Notes: (1) | The Design Review or Conditional Use Permit process may require larger setbacks. (2) | The North Station Area (-SA) or Downtown Station Area (-DSA) Combining Districts may require special setbacks. (3) | A one- story portion may project up to 6 ft into the setback and required stairs and landings may project up to 10 ft into the setback. (4) | Properties that abut residential and historic residential uses and zoning districts, maximum height shall transition down to a max. of 3 stories adjacent to the residential property.

( Ord. 3677 § 1, 2004 ; Ord. 3711 § 1 Exh. A, 2005 ; Ord. 3950 §§ 6, 7, 2010 ; Ord. 2020-014 § 8 ; Ord. 2021-012 § 10 ; Ord. 2025-014 , 11/18/2025 )

Ask a question about Santa Rosa law

Corpus searches the Santa Rosa sections it holds and shows the ones that match, with their citations. Free, no sign-in.