For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 20-30.060 — Fences, walls, and screening

Code of Ordinances, City of Santa Rosa, California (Code 2026-09-15: eCode360 publication current through Ord. No. 2026-014 adopted September 15, 2026 (scraped 2026-11-20)) · Santa Rosa Code of Ordinances § 20-30.060

Corpus is an independent public-information project, not the official City of Santa Rosa website. Stable reference: corpuslaw.us/code/8f950c70-657b-4784-972a-237a16da58b4

§ 20-30.060: Fences, walls, and screening.

A. Purpose. This section provides regulations for the installation, construction, and placement of fences on private property. For the purposes of this Zoning Code, the term "fence" includes fences, hedges, walls or structures in the nature of a fence. B. Measurement of fence and wall height. 1. Fence height shall be measured as the vertical distance between the finished grade at the base of the fence and the top edge of the fence material. 2. The height of fencing atop a wall shall be measured from the base of the wall. 3. Where the ground elevation within six feet of the base of a fence differs from one side of the fence to the other (as when a fence is placed at the top of a slope or on a retaining wall), the height shall be measured from the side with the lowest natural grade; except that a safety fence with a height of 42 inches shall be allowed on the top of a retaining wall of 30 inches or more in height with Minor Use Permit approval. See Figure 3-3. [image] Figure 3-3—Fence Height Measurement C. Height limits. A fence in a residential zoning district is subject to the following restrictions: 1. Single family dwelling shall not exceed the height limits shown in Table 3-1, unless authorized in compliance with Subsection D of this section (Additional height with Director Conditional Use Permit approval). See also Figure 3-4. 2. Multifamily dwelling and non-residential properties will require Design Review approval and are not subject to the height limits shown in Table 3-1. TABLE 3-1—MAXIMUM HEIGHT OF FENCES Location | Maximum Height (1) Within required front yard setback | 36 inches Within interior side or rear yard setback | 6 feet (2) Within exterior side setback | 36 inches Within a vision triangle (see Section 20-30.070.E) | No fence allowed, except as provided by Section 20-30.070.E (Vision Triangles). Outside of a required setback | 6 feet (2) Notes: (1) | See the City's Processing Review Procedures for Owners of Historic Properties for fence height guidelines with an -H (Historic) combining district. (2) | A six-foot fence with two feet of lattice is allowed by right in an interior side or rear yard setback, and outside of a required front or street side setback (see Figure 3-5); provided that any fence exceeding seven feet in height requires a Building Permit. [image] Figure 3-4—Allowed Fence Height [image] Figure 3-5—Lattice Allowed for Additional Fence Height D. Additional height with Director Conditional Use Permit approval. A fence may be constructed to a height in excess of the limits established by Subsection C with Director Conditional Use Permit approval, except within a required vision triangle (Section 20-30.070E). Director Conditional Use Permit approval shall require that the review authority first make all of the following findings, in addition to those required for Director Conditional Use Permits by Section 20-52.050: 1. The issuance of the permit is reasonably necessary, by reason of unusual or special circumstances or conditions relating to the property, for the preservation of valuable property rights or the full use and enjoyment of the property; 2. The fence will not create a safety hazard to pedestrians or vehicular traffic; 3. The appearance of the fence is compatible with the design and appearance of other existing buildings and structures within the neighborhood; 4. The fence is a planned architectural feature to avoid dominating the site or overwhelming the adjacent properties and structures; 5. The orientation and location of the fence is in proper relation to the physical characteristics of the site and the surrounding neighborhood; and 6. The fence will be of sound construction. E. Fire hazards. The Building Official shall not grant a building permit for any fence that will interfere with access in case of fire by the Fire Department to buildings in the vicinity, or that will constitute a hazard to vehicle traffic or pedestrians. F. Temporary fences—Exceptions. Nothing in this Zoning Code shall be deemed to prohibit the erection of a temporary fence around construction works in compliance with the Building Code and other applicable provisions of the City Code. G. Barbed wire. Barbed wire fencing shall not be constructed or placed over a fence except in agricultural, open space, or industrial areas. Minor Conditional Use Permit approval shall be required for barbed wire fencing abutting residential uses. H. Screening. 1. Proposed development within commercially or industrially zoned sites that are adjacent to any residential zoning district shall provide screening between districts, subject to Design Review. 2. Outdoor storage areas in any commercial or industrial zoning district shall be permanently screened from view from any adjacent public right-of-way, access easement, or adjacent private property in compliance with Section 20-42.170 (Storage, Outdoor), and Section 20-30.090.L.1.g (Security—Dumpsters).

( Ord. 3677 § 1, 2004 ; Ord. 2021-012 § 20 ; Ord. 2025-014 , 11/18/2025 ; Ord. 2026-006 , 4/21/2026 )

Ask a question about Santa Rosa law

Corpus searches the Santa Rosa sections it holds and shows the ones that match, with their citations. Free, no sign-in.