For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 9-24.050 — Securing from trespassers

Code of Ordinances, City of Santa Rosa, California (Code 2026-09-15: eCode360 publication current through Ord. No. 2026-014 adopted September 15, 2026 (scraped 2026-11-20)) · Santa Rosa Code of Ordinances § 9-24.050

Corpus is an independent public-information project, not the official City of Santa Rosa website. Stable reference: corpuslaw.us/code/7f965668-1162-46fe-a351-a1e3ed683adc

§ 9-24.050: Securing from trespassers.

All real properties which exist as unmaintained vacant lots, or which contain vacant or abandoned buildings shall be secured against trespassing in the following manner: (A) All doors and windows of the building shall be in good, working condition and secured against unauthorized entry. (B) All broken doors and windows shall be replaced or covered in a manner acceptable to and approved by the Code Enforcement Division. (C) The Code Enforcement Division, in its discretion, may require securing the property in an approved manner to ensure adequate protection against unauthorized entry, or by any other reasonable measures to prevent trespassers. These protections include, but are not limited to, plywood boarding of all windows and doors and/or the erection of fencing. Plywood boarding, where used, shall be painted to match the exterior color of the structure, and shall be subject to the following standards: (1) Unless additional measures are determined necessary by the Code Enforcement Division, plywood boarding of all windows and doors shall at a minimum be performed as specified in this section and in the following figures: [image] (2) Specifications for Plywood Boarding. (a) Exterior Plywood shall be of un-sanded CDX grade; (b) Plywood thickness shall be 1/2 inch for window openings, 5/8 inch for door openings and 3/4 inch for sliding door and French door openings. When extra-large window openings are encountered use 5/8 inch or 3/4 inch as necessary; (c) All holes shall be drilled to accommodate round head carriage bolts. The holes in the top of the plywood should be 12 inches down from the top and 20% of the width of the plywood cover, in from the side; (d) The holes in the bottom should be 25 percent of the height of the plywood, up from the bottom and the same distance in from the side as the top; (e) Carriage bolts mated with nut and two three-inch flat washers as shown in the side view. Washers shall be of sufficient size to fully accept the square portion of bolt beneath the head. Bolt and mating hardware may be galvanized, or cadmium plated. 3/8 inch x 12 inch bolts should be supplied with each 2 foot 8 inch door, 3 feet 0 inch door, and glass sliding door cover. 3/8 inch x 10 inches bolts should be supplied with the rest; (f) 2 inch x 4 inch lumber should be graded and should be a minimum of 16 inches longer than the width of the plywood cover. (Note: 2x4s shall be drilled with 1/2 inch diameter holes that line up with the holes in the plywood covers.); (g) All windows and doors, except the front door (unless front door is missing), through which access to the interior of the dwelling is made, shall be secured. All window boards shall be cut to fit inside window openings with a maximum 1/8 inch clearance. The plywood covering shall be of one continuous piece when possible; (h) All fabricated parts and ancillary materials become property of the property owner; and (i) All coverings are to be fabricated according to the attached drawing and specifications. (3) Boarding Windows. (a) Except as noted below, all window sashes, frames, glass, and hardware are to be undamaged by the boarding installation; (b) All screen inserts are to be removed, marked as to location, and stored within the building; (c) In all cases where it is possible to adjust the position of the sashes to accommodate the specifications for boarding above, the sashes are to remain in the frame; (d) In instances wherein the sashes cannot be adjusted to accommodate the boarding specifications above, the sashes shall be removed from the frames and stored within the building. This includes all stationary side- or top-lights secured by stops; (e) In cases wherein the sash cannot be removed and/or the frame is permanently built into the house and cannot be removed (i.e., Fenestra windows) it will be necessary to break the corner panes to accommodate the boarding and bolts. If the location of bolt holes in the plywood requires modification because of the muntin bar (a small bar that divides a windows glass), these locations are to be modified. In no case, in any type of window, is any sash or frame part to be damaged; (f) In all instances where items should be removed from the frame and stored, each item shall be clearly marked as to the area from which it was removed; (g) All items are to be stored on edge and braced to prevent accidental tipping, sliding, etc. In no instance is any item to be stored laid flat; (h) Hinged windows are to be completely removed from the frame and stored as stated in subsection (C)(3)(g) above. If possible the hinge pins are to be removed and remain with the removed item; and (i) Faced nailing of panels to wood frame windows is specifically prohibited.

( Ord. 2024-003 , 2/27/2024 )

Ask a question about Santa Rosa law

Corpus searches the Santa Rosa sections it holds and shows the ones that match, with their citations. Free, no sign-in.