§ 512.0504 — Ignition-Resistant Construction
San Diego Municipal Code (City Clerk PDFs, pages revised through October 2026) · San Diego Municipal Code § 512.0504
Corpus is an independent public-information project, not the official City of San Diego website. Stable reference: corpuslaw.us/code/dfc7ea49-8923-4d06-9478-ceb4364f836e
§512.0504 Ignition-Resistant Construction
(a) Local Addition. Section 504.2.3, Drip Edge Flashing, is added as follows: When drip edge flashing is used at the free edges of roofing materials, it must be non-combustible. (b) Local Addition. Section 504.8.3, Vinyl Window Reinforcing, is added as follows: Glazing frames made of vinyl materials shall have welded corners, metal reinforcement in the interlock area, and be certified to the most current edition of American Architectural Manufacture’s Association (AAMA)/Window and Door Manufacture’s Association (WDMA)/Canadian Standards Association (CSA) 101/I.S.2/A440-22 structural requirements.
(“Ignition-Resistant Construction” added 1-29-2026 by O-22042 N.S.; effective 2-28-2026.)
Ask a question about San Diego law
Corpus searches the San Diego sections it holds and shows the ones that match, with their citations. Free, no sign-in.