Chapter 9 — FIRE-PROTECTION SYSTEMS

San Francisco Administrative Code (2026 S-96: through Ordinance 133-26, File No. 260686, approved July 23, 2026, effective August 23, 2026), San Francisco, CA · 44 sections. Independent public-information project, not the official City of San Francisco website.

  1. § 901.2.1 — For SF CERTIFICATED FIRE ALARM SYSTEM. 1
  2. § 901.8.3 — Subsurface Construction
  3. § 902 — - DEFINITIONS
  4. § 903 — - AUTOMATIC SPRINKLER SYSTEMS
  5. § 903.3.6.1 — Fire Department Hose Connection Type
  6. § 903.3.11 — Installation Personnel Qualifications
  7. § 903.5.1 — Testing, and Maintenance Personnel Qualifications
  8. § 904 — - ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
  9. § 904.13.5.2 — For SF Extinguishing System Service
  10. § 905.2.1 — Local Installation Standard
  11. § 905.3.1.1 — For SF Stages
  12. § 905.3.12 — Buildings with Limited Fire Department Access
  13. § 905.4.3 — Local Requirement for Location of Class I Standpipe Hose Connections
  14. § 905.4.4 — Local Standpipe Requirements
  15. § 907.1.6 — Installation Personnel Qualifications
  16. § 907.1.7 — Fire Alarm and Signaling System Submittals
  17. § 907.1.8 — Fire Alarm System Design Professional
  18. § 907.2.9.1 — For SF Manual fire alarm system
  19. § 907.2.9.4 — Automatic smoke detection system
  20. § 907.2.11.9 — Smoke Alarm Information Disclosure
  21. § 907.6.4.1.1.1 — Local Annunciation Requirement
  22. § 907.6.4.1.1.2 — Graphic Annunciation
  23. § 907.6.4.3 — For SF High-rise Buildings Zoning Annunciator Panel
  24. § 907.7.4 — Fire Alarm Certification Required
  25. § 907.8.4 — For SF Inspection, Testing, and Maintenance
  26. § 907.8.5 — Certificated Fire Alarm Systems for Existing Buildings
  27. § 907.8.6 — Reporting of Fire Alarm System Operational Matrix
  28. § 907.8.7 — Inspection, Testing, and Maintenance Personnel Qualifications
  29. § 909 — - SMOKE CONTROL SYSTEMS
  30. § 909.4 — For SF Analysis
  31. § 909.4.8 — Active and Passive Zones
  32. § 909.4.9 — Specific Submittal Criteria for Reports, Special Inspections and Final Acceptance Testing of Smoke Control Systems
  33. § 912.8 — Number of connections required
  34. § 912.9 — Local FDC Requirements
  35. § 913.1.1 — Local Fire Pump Requirements
  36. § 913.2.3 — Integrity of the fire pump room
  37. § 914 — - FIRE PROTECTION BASED ON SPECIAL DETAILED REQUIREMENTS OF USE AND OCCUPANCY
  38. § 914.3.1.1 — For SF Number of Sprinkler System Risers and System Design
  39. § 914.3.1.2.2 — Fire pump drives
  40. § 914.3.1.3 — Fire Department Connections
  41. § 914.3.2.1 — Integrity of fire water storage tank
  42. § 914.3.2.2 — Tank overflow line and drain line routing
  43. § 914.3.2.2.1 — Drain ejector pumps (Sump Pumps)
  44. § 914.12 — Piers