§ 15.10.040 — Amendments

Stockton Municipal Code, California (Code 2026-10-13: eCode360 publication current through the 2026-10-13 codification (scraped 2026-11-17)) · Stockton Municipal Code § 15.10.040

Corpus is an independent public-information project, not the official City of Stockton website. Stable reference: corpuslaw.us/code/fde28c58-c705-4c24-ae2e-ecd0924017df

§ 15.10.040: Amendments.

Notwithstanding the provisions of Section 15.10.010, the California Residential Code is amended as follows: A. Section R313.2.1 of the 2025 California Residential Code is hereby amended and shall read as follows: Automatic sprinkler systems shall be designed and installed in accordance with Section R313 or NFPA 13D. Automatic fire sprinkler systems installed in one- and two-family dwellings; Group R3; and townhouses shall be permitted to be installed throughout in accordance with NFPA 13D, as amended in Chapter 80 of the California Fire Code. 1. Pre-manufactured homes shall not apply. 2. Fire damage repair or other naturally caused damage to R3 occupancies shall not require an automatic fire sprinkler system unless the structure is to be demolished and rebuilt. 3. Residential additions that exceeds 50 percent (except additions specifically for the creation of an ADU) of the overall area of the existing structure shall require an automatic fire sprinkler system be installed throughout the building per NFPA 13D. 4. Attic spaces in Group R3 occupancies shall have pilot heads installed in each roof pitch of a compartmentalized attic in addition to the forced air unit (FAU). 5. Passive purge connection required in lieu of a backflow prevention device. CPVC piping shall be brought down to the toilet sub out. 6. Spare sprinkler head box shall be required with minimum three (3) spare sprinkler heads, and/or one (1) each per type of sprinkler head provided and a wrench. 7. An electric bell shall be installed on the exterior of the building and have a dedicated circuit with lockout on breaker. 8. Fire sprinkler heads shall be required under any stairwell where a compartment, room, and/or closet is located. 9. Newly constructed single-family homes: Covered and enclosed patios, California rooms and/or similar outdoor rooms or living spaces where a natural gas line for a fuel-fired appliance is permanently installed shall have fire sprinkler protection. B. Section R313.2.1.1 of the 2025 California Residential Code is hereby added and shall read as follows: Quick-Response and Residential Sprinklers. Where automatic sprinkler systems are required by this code, quick-response or residential automatic sprinklers shall be installed in dwelling units and sleeping units in Group R occupancies in accordance with Section 903.3.2 of the California Fire Code (2025 Edition) and their listings.

( Ord. 2022-11-15-1203 C.S. § 2 ; Ord. 2025-11-18-1206 , 11/18/2025 )

Ask a question about Stockton law

Corpus searches the Stockton sections it holds and shows the ones that match, with their citations. Free, no sign-in.