§ 16.36.090 — Height measurement and height limit exceptions
Stockton Municipal Code, California (Code 2026-10-13: eCode360 publication current through the 2026-10-13 codification (scraped 2026-11-17)) · Stockton Municipal Code § 16.36.090
Corpus is an independent public-information project, not the official City of Stockton website. Stable reference: corpuslaw.us/code/d8214ffc-f49a-46b0-820d-5faf6e8fa774
§ 16.36.090: Height measurement and height limit exceptions.
A. Maximum Height. The height of structures shall not exceed the standard established by the applicable zoning district in Chapter 16.24 (Zoning District Development Standards), or other provision of this Code, except as provided in Section 16.36.090.C (Exceptions to Height Limits), or as specifically identified in another section of this Code. B. Maximum Height. Maximum height shall be measured as the vertical distance from the finish grade to an imaginary plane located the allowed distance above, and parallel to, the finish grade, or as provided by the California Building Standards Code. [image] FIGURE 3-3 HEIGHT MEASUREMENT C. Exceptions to Height Limits. The structures listed below may exceed the maximum permitted height for the district in which they are located, subject to the limitations stated and further provided that no portion of a structure in excess of the height limit may contain habitable areas or advertising. 1. Roof-Mounted Structures. Roof-mounted structures for the housing of elevators, stairways, tanks, ventilating fans, wind power equipment, chimneys, flag poles, towers, skylights, smokestacks, wireless masts, or similar equipment required to operate and maintain the structure, shall be allowed, up to a maximum of 15 feet above the structure height. The structures shall be screened in compliance with Section 16.36.100 (Screening and buffering). The total square footage of all structures above the heights allowed in the zoning districts shall not occupy more than 25% of the total roof area of the structure. 2. Communications Facilities. Communication facilities, including antennae (television, radio, cellular, etc.), poles, towers, and necessary mechanical appurtenances, are subject to the provisions of Chapter 16.44 (Communications Facilities). 3. Parapet Walls. Fire or parapet walls in nonresidential zoning districts may extend up to four feet above the allowable height limit of the structure. [image] FIGURE 3-4 PARAPET WALL HEIGHT
( Prior code § 16-310.090 ; Ord. 023-07 C.S. § 19 ; Ord. 015-09 C.S., eff. 12-3-09 ; Ord. 2020-12-01-1502 C.S. § 5 ; Ord. 2025-06-03-1601 , 6/3/2025 )
Ask a question about Stockton law
Corpus searches the Stockton sections it holds and shows the ones that match, with their citations. Free, no sign-in.
