For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16.48.070 — Materials

Stockton Municipal Code, California (Code 2026-10-13: eCode360 publication current through the 2026-10-13 codification (scraped 2026-11-17)) · Stockton Municipal Code § 16.48.070

Corpus is an independent public-information project, not the official City of Stockton website. Stable reference: corpuslaw.us/code/e3a68965-47b1-485b-bca2-ed5ab3350849

§ 16.48.070: Materials.

A. Chain-Link Fencing. 1. Residential Uses and Districts. Chain-link fencing is prohibited in residential districts and for residential uses in nonresidential districts. 2. Nonresidential Uses in Commercial and Industrial Districts. Chain-link fencing is prohibited within 10 feet of a front or street-side property line. Any chain-link fencing must be vinyl-coated, B. Barbed Wire/Razor Wire Fencing. Barbed wire and razor wire fencing is prohibited in residential districts or adjacent to public rights-of-way in commercial and industrial districts. All barbed wire, razor wire, or other sharp pointed material may only be used in the construction of a fence if it is at least seven feet above ground level and not visible from any adjacent public street. C. Tarp Fencing. Tarp fencing shall be prohibited in all zoning districts. D. Electrified Fencing. The use of electrified fencing, for security or other purposes, is prohibited in all zoning districts, except in the CG, CA, CL, CH, IL, IG, and PT districts. Said fencing shall comply with the following requirements: 1. Electrified Fences in the CG, CA, CL, and CH Districts. The following uses are eligible for electrified fencing in the CG, CA, CL, and CH Districts: a. Marinas; b. Construction, farm and heavy equipment sales; c. Personal storage facilities; and d. Minor communication facilities. 2. Permits Required. Any electrified fencing shall require the approval of the following permits: a. Land Development Permit. A land development permit in compliance with Chapter 16.136 (Land Development Permits) when located in the CG, CA, CL, or CH District, except as otherwise approved by another discretionary application for a project on the same site. b. Alarm Permit. An alarm permit obtained from the Police Department. For this program, all applicable alarm fees apply to electric fence installations. (See Title 8, Chapter 8.44 "Intrusion Detection Devices and Burglar Alarm Systems.") c. Building Permit. A building permit in compliance with Title 15, Buildings and Construction. 3. General Requirements. The following electrified fencing standards shall apply to all development: a. Electrical Standard. Unless otherwise specified herein, electrified fences shall be constructed or installed in conformance with applicable provisions of International Electrotechnical Commission (IEC) standards for electric fence energizers, as well as applicable provisions of the California Electrical Code (CEC), as necessary. b. Electrification. i. The energizer for electric fences must be driven by a commercial storage battery not to exceed 12 Volts DC or other approved 12-Volt DC or less power source. ii. The electric charge produced by the fence upon contact shall not exceed energizer characteristics set forth in the IEC standard for electric fence energizers. iii. Non-low voltage electrical components (e.g., controllers, transformers) of the electric fencing system shall be approved and listed by an Occupational Safety and Health Act nationally recognized testing laboratory. c. Perimeter Fence or Wall. Except as required by subsection D.3.h (Adjacent to Residential Zones or Uses), electrified fencing shall be completely surrounded by a non-electrified fence or wall that is not less than six feet tall and has no barbed, concertina, or similar wire attached. Vehicle access gates along public rights-of-way may be exempted from this requirement, subject to approval of a land development permit in the CG, CA, CL, or CH District or another discretionary application for a project on the same site. Any barbed, concertina, or similar wire on existing fences shall be removed prior to the installation of the electric fence. Existing developed properties with legally-built existing chain-link fencing may retain said fencing when located closer than 10 feet from the front and side property. Similarly, vinyl coating on said fencing is not required. d. Setback. i. Any opening in the perimeter fence less than or equal to three inches shall require a minimum one-foot setback from the electric fence (IEC 60335-2-76 Standard). ii. Any opening in the perimeter fence greater than three inches shall require a minimum three-foot setback from the electrified fence or the installation of an approved mesh between electrified fence and non-electrified fence. e. Height. Electrified fencing shall not have a height in excess of 10 feet. f. Warning Signs. Electric fences shall be clearly identified with 12-inch by 18-inch warning signs on both the inside and outside of the fence. The signs shall read "Warning-Electric Fence" in English with international symbols and other languages as required by the Land Development Permit in the CG, CA, CL, or CH District, at intervals of not greater than 30 feet. Warning signs shall be maintained in good condition at all times to ensure visibility. g. Emergency Access. A "Knox Box" or other similar approved devices shall be installed for emergency access by Police and Fire Departments. A means to disconnect electrical power to the fence shall be readily available to the Police and Fire Departments. Disconnect switches and controls shall be in an accessible location on the property and shall not be obscured in any manner from the street/private driveway access. Approved signs stating the identification of such switches/controls in addition to informational instructions as to how to disable the electrical system shall be installed to the satisfaction of the Fire Marshal. In accordance with Section 8.44.090, a notice shall be posted at each gate (pedestrian and vehicle gates) indicating a 24-hour contact name and phone number or said information shall be filed and kept updated with the Police Department. In the event that access by the City of Stockton Fire Department and/or Police Department personnel to a property where a permitted electric fence has been installed and is operating is required due to an emergency or urgent circumstances, and the Knox Box or other similar approved device above is absent or non-functional, and an owner, manager, employee, custodian, or any other person with control over the property is not present to disable the electric fence, fire or police personnel shall be authorized to disable the electric fence in order to gain access to the property. As a condition of permit issuance, all applicants issued permits to install or use an electric fence as provided in this chapter will agree to waive any and all claims for damages to the electric fence against the City of Stockton and/or its personnel under such circumstances. h. Adjacent to Residential Districts or Uses. Electric fences may abut residentially-zoned or residentially-used property when there is a non-electrified wall at least eight feet in height between the electrified fence and residential district or use.

( Ord. 2025-06-03-1601 , 6/3/2025 )

Ask a question about Stockton law

Corpus searches the Stockton sections it holds and shows the ones that match, with their citations. Free, no sign-in.