For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16.80.390 — Industrial warehouse standards

Stockton Municipal Code, California (Code 2026-10-13: eCode360 publication current through the 2026-10-13 codification (scraped 2026-11-17)) · Stockton Municipal Code § 16.80.390

Corpus is an independent public-information project, not the official City of Stockton website. Stable reference: corpuslaw.us/code/cfa8cabd-8784-4d15-afb1-b4da31b109da

§ 16.80.390: Industrial warehouse standards.

This section establishes standards for logistics warehouses in zoning districts where they are allowed in compliance with the provisions of Division 2 (Zoning Districts, Allowable Land Uses, and Zone-Specific Standards). A. Applicability. The standards will apply to the following applications: 1. To all logistics warehouses 400,000 square feet in size or greater. Logistics Warehouses are considered facilities used for the storage of farm products, furniture, household goods, or other commercial goods for distribution to wholesalers and/or retailers, including cold storage. 2. The standards provided in this section (SMC 16.80.390) shall not apply to any new building constructed on property that was incorporated into the City of Stockton prior to December 31, 2023. B. Development Standards. 1. Site Plan Design. The following standards shall apply to all entitlement reviews (site plan), grading and improvement plans, and construction permit reviews associated with facilities subject to the Logistics Warehouse standards. A copy of these standards shall be included on the approved (issued) construction plan and kept on-site during all phases of construction. a. Unless determined to be physically impossible, when adjacent to sensitive receptors, a loading dock door shall be oriented away from the sensitive receptor and located a distance of 300 feet from said receptor, unless the dock doors are utilized by zero emission trucks and equipment only. A sensitive receptor shall be defined as schools, health care facilities, libraries, churches, correctional facilities, parks/recreational facilities, in home daycare, health facilities (hospitals, long term care facilities, retirement, and nursing homes) or more than two directly contiguous residential units. The following may be included within the 300 feet distance: the building; auto parking; and other site design and use elements, including but not limited to, stormwater basins, employee gathering areas (daytime use), pedestrian and bicycle pathways, outdoor storage, and a drive aisle for auto, truck and emergency vehicle circulation around the building, provided the drive aisle is placed immediately adjacent to the building and not abutting a sensitive receptor. b. A 20-foot landscaped planter (buffer) shall be installed along the property line adjacent to a sensitive receptor. c. The buffer shall be landscaped and not be less than 50% of the total buffer size with two rows of 15-gallon trees planted along the length of the property line adjacent to the sensitive receptor. d. The buffer landscape can include areas to be used for bioswales, retention/detention areas and/or other stormwater and water quality management areas in compliance with SMC Chapter 16.56 (Landscaping). e. The buffer area shall include a minimum 10-foot solid decorative wall(s), or landscaped berm and wall, or landscaped berm adjacent to sensitive receptors unless a noise analysis indicates an alternative height is needed for sound attenuation. f. All on- and off-site landscaping shall comply with SMC Chapter 16.56 (Landscaping). g. All landscaping shall be drought tolerant and, to the extent feasible, comprised of species with low biogenic emissions. Palm trees shall not be utilized. h. All landscaping areas shall be properly irrigated for the life of the facility to allow for plants and trees to maintain growth with no undue pruning. i. Tree maintenance shall comply with SMC Chapter 16.56 as a certified Landscape Architect must prepare the Preliminary and Final Landscape plan and certify the planting is water efficient at the time of construction permit approval. j. Trees shall be installed in automobile parking areas to provide at least 35% shade cover of passenger vehicular parking areas within 15 years. Trees shall be planted that can meet this requirement. The 35% shade created by trees amount can be substituted for solar canopy upon approval by the Director. k. To facilitate the installation of future electric vehicle charging stations for light-heavy duty (LHD), medium-heavy duty (MHD), heavy-heavy duty (HHD) trucks, in connection with each individual development proposal, the subject building improvement plans shall identify an area for future LHD, MHD, HHD truck charging stations and the subject developer shall install conduit from the power source to the identified area. l. Provide EV charging stations for automobiles per building code and provide conduit to a future designated area for Heavy Duty Turck Charging Facility. m. All truck turning movements at entrances, exits, and street intersections shall be located on local industrial, collector or arterial streets and all vehicle entries shall be designed to prevent truck access to local and back-up residential collector streets. n. All trucks and commercial vehicles serving the facility shall occur in compliance with the City of Stockton Truck Traffic Route Map in SMC Section 10.08.030 and Surface Transportation Assistance Act (STAA) Truck Route Map. o. Off-street loading shall comply with Section 16.64.110 Off-street loading space standards and Section 16.36.030 to ensure driveway access and on-site circulation are designed and maintained to increase public safety and reduce congestion on public streets. p. Signs shall be posted inside and outside of the building and facility indicating all off-site parking is prohibited for adjacent street that do not permit parking. q. All truck driveway exits shall include signs directing truck drivers to the truck routes identified in the City of Stockton Truck Traffic Route Map and State Highway System designations. r. Upon commencement of operations, the tenant/operator of the facility shall be required to restrict truck idling on site to a maximum of three minutes, subject to exceptions defined by CARB's commercial vehicle idling requirements. 2. Building Design. The following standards shall apply to all entitlement reviews (design review), grading and improvement plans, and construction permit reviews associated with facilities subject to the Logistics Warehouse standards. A copy of these standards shall be included on the approved (issued) construction plan and kept on-site during all phases of construction. a. All qualifying facilities shall be constructed using "cool roof" materials with an aged reflectance and thermal emittance values that are equal to or greater than those specified in the current edition of the California (CAL) Green Building Tier 1 Standards. b. Architectural and industrial coatings (e.g. paints) applied on the qualifying facility(ies) shall be consistent with the Volatile Organic Compound (VOC) content limits set by the San Joaquin Valley Air Pollution Control District (SJVAPCD) or the current edition of the California Green Building Standards Code (CALGreen), whichever is most restrictive. Developer or tenant is not required to exercise control over materials painted offsite. c. Qualifying facilities shall be constructed in compliance with the most current edition of all adopted City building codes, including the adopted Green Building Standards Code. Prior to the issuance of building permits, the applicant/developer of the qualifying facility(ies) shall demonstrate (e.g., provide building plans) that the proposed buildings are designed and will be built. d. Each developer of an individual specific development proposal shall prepare the subject building structures in such a way to accommodate future solar panels pursuant to applicable Building Code requirements. e. The building permit application for qualifying facilities must demonstrate that sufficient power will be provided from clean energy sources for the operational base power use at the start of operations. Developers shall have the following options, or any combination of options, for procuring clean energy to meet operational base power needs for new building structures. Options may include: (1) installing solar panels on the subject building or building site; and/or (2) procuring 100% clean energy from AVA Community Energy; and/or (3) participating in California's Community Solar Program. f. Operational base power is defined as the amount of power required to supply loads for all ordinary operational uses of the site. Loads for all ordinary operational uses of the site include, as non-exhaustive examples, loads for minimal heating for fire sprinklers, primary office space lighting, HVAC, warehouse power, warehouse lighting, site lighting, minimum power for dock positions (including chargers for yard equipment and any plug-ins for transport refrigeration units), and the amount of light-duty electric vehicle supply equipment required by CalGreen code. Loads for all ordinary operational uses of the site exclude, as non-exhaustive examples, loads for specialized equipment, non-standard automation or material handling systems, and chargers for heavy-duty trucks. g. The office portion of a building's rooftop that is not covered with solar panels or other utilities shall be constructed with light colored roofing material with a solar reflective index of not less than 78. h. Electrical Room Sizing. To ensure that warehouse electrical rooms are sufficiently sized to accommodate the potential need for additional electrical panels, either a secondary electrical room shall be provided in the building, or the primary electrical room shall be sized 25% larger than is required to satisfy the service requirements of the building or the electrical gear shall be installed with the initial construction with 25% excess demand capacity. i. Warehouse Dock Seal Doors. Exterior loading dock doors that are adjacent to conditioned or indirectly conditioned spaces shall have dock seals or dock shelters installed at the time of permitting. j. On-Site Equipment Infrastructure. Project should provide infrastructure to support charging of electric power on-site equipment. k. Demonstration of compliance with the San Joaquin Valley Air Pollution Control District (SJVAPCD) Rule 9510 (Indirect Source Review) is required prior to obtaining any building permit for a qualifying facility. l. Tenant/Operator of the qualifying facility(ies) shall enroll in the United States Environmental Protection Agency's SmartWay Program. Proof of enrollment shall be given to the Community Development Department prior to issuance of a Certificate of Occupancy of a Building Permit for the facility. 3. Construction Permit Approval. The following standards shall apply to all construction related activity associated with facilities subject to the Logistics Warehouse standards. A copy of these standards shall be included on the approved (issued) construction plan and kept on-site during all phases of construction. a. Qualifying facilities shall comply with the San Joaquin Valley Air Pollution Control District (SJVAPCD) requirements prior to beginning construction. b. All off-road construction equipment, with a power rating of less than 19 kilowatts (e.g., plate compactors, pressure washers, shall be electric-powered. c. Subject to all other idling restrictions, off-road diesel-powered construction equipment shall not be left in the "on position" for more than 10 hours per day. d. Temporary electrical hookups to all construction yards and associated work areas shall be required. e. Temporary signage shall be posted in public view throughout the construction site indicating truck idling lasting more than five minutes is prohibited. The signs shall include contact information for the facility operator or designee responsible for receiving complaints (i.e. excessive dust, fumes, odors) for the site, and contact information for the San Joaquin Valley Air Pollution Control District's on-line complaint system and its complaint call-line for those interested in filing a complaint. Any complaints made to the facility operator's designee shall be answered within 72 hours of receipt. f. The construction contractor(s) shall maintain on the construction site an inventory of construction equipment, maintenance records, and datasheets, including design specifications and emission control tier classifications. g. The facilities shall require the construction contractor to establish one or more locations for food or catering truck service to construction workers and to cooperate with food service providers to provide consistent food service. h. The facilities shall require the construction contractor to provide transit and ridesharing information for construction workers. C. On-Going Operations: The following standards shall be implemented during all on-going business. 1. All forklifts, yard trucks, and other equipment used for on-site movement of trucks, trailers, and warehoused goods, as well as landscaping maintenance equipment used on the site, shall be electrically powered or zero-emission unless new technology is determined to be commercially unavailable. 2. Where transport by temperature-controlled trucks or trailers is proposed, on-site electrical hookups shall be provided at loading docks. Idling or use of auxiliary truck engine power to power climate-control equipment shall be prohibited. 3. Employers shall provide employees with transit route and schedule information on systems serving the facility area and coordinate ridesharing amongst employees. 4. Employers shall provide on-site locations for food or catering truck service and cooperate with food service providers to accommodate food service to operations employees. 5. All outdoor areas allowing smoking shall be located at least 25 feet from the nearest property line. 6. All trucks, supportive vehicles and equipment shall be kept on site in all loading, storage, and parking areas, and kept behind locked gates during nonbusiness hours. 7. Truck queuing, idling, or circling of vehicles, on public streets adjacent to the facility is prohibited. 8. Periodic yard and parking area sweeping shall be provided to minimize dust generation. 9. Diesel Generators are prohibited, except in emergency situations and during construction when establishing the facility's new electrical service connection. In those temporary cases, all generators shall have Best Available Control Technology (BACT) that meets CARB's Tier 4 emission standards.

( Ord. 2023-12-12-1602 , 12/12/2023 ; Ord. 2024-07-09-1602 , 7/9/2024 )

Ask a question about Stockton law

Corpus searches the Stockton sections it holds and shows the ones that match, with their citations. Free, no sign-in.