For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.06.080 — Hillside development standards

Municipal Code, City of Temecula, California (legislation through Ord. No. 2026-04 adopted April 14, 2026) · Temecula Municipal Code § 17.06.080

Corpus is an independent public-information project, not the official City of Temecula website. Stable reference: corpuslaw.us/code/12628c8e-ab97-4eee-8250-977561b78738

§ 17.06.080: Hillside development standards.

A. Purpose and Intent. This section is established to achieve the city's objective to facilitate and permit the orderly development of property within the HR-SM zone in the Santa Margarita area annexation through a set of hillside development standards aimed at protecting the public health, safety and welfare; protecting and preserving natural and biological resources for long-term benefit of the city and the broader community, recognizing the inherent value in the properties subject to the HR-SM zone; allowing size, type, location, density, and intensity of development based on available infrastructure; the geographic steepness of terrain, presence of unique geographic conditions and constraints; and presence of environmentally sensitive areas; and optimizing the use of sensitive site design, grading, landscape architecture, and architecture, all to achieve the city's objectives. Specific regulations and standards address the following city objectives: 1. To protect the value of the community and the subject property of ridgelines, prominent landforms, rock outcroppings, open space areas, hydrologic features, wildlife communities, unique and sensitive habitat and vegetation communities, and other natural, biological, archaeological/historical, and scenic resources; 2. To preserve the visual and aesthetic quality of hillsides as viewed from the surrounding community; 3. To promote and encourage a variety of high quality, alternative architectural and energy efficient development designs and concepts appropriate for hillside areas; 4. To preserve the public health, safety, and welfare and specifically protect the public and property from hazards such as seismic, geologic, and fire. B. Applicability and Permit Required. This section applies to all properties within the Santa Margarita area annexation that are located within the HR-SM zoning district. In addition to any other permit or approval required by this code, any person proposing to subdivide, grade, erect, or construct into, over, or on top of property within the HR-SM zoning districts shall first obtain a land use entitlement through the approval of a hillside development permit pursuant to Section 17.04.060 to ensure compliance with this section. C. Definitions. The following terms shall have the following meanings for purposes of this section: "Accessory facilities" mean buildings, structures, roads, driveways, walls or fences incidental to permitted, or conditionally permitted, use. "Disturb" means to alter the natural surface of the land or the natural vegetation by any means, including, but not limited to, grading, clearing, brushing, grubbing, or landscaping. "Graded slope" means all the faces of a graded slope, from the toe of the slope to the top of the slope, whether the faces are covered by natural vegetation, riprap, retaining walls or other material. "Hill" means a well-defined natural elevation that extends above surrounding terrain. "Hillside" means the side or slope of a hill. "Hillside development permit" means an entitlement based upon an application which includes all required submittal documents that comprehensively evaluated to determine its impacts on neighboring property and the community as a whole, from the standpoint of the site, landscape design, architecture, materials, colors, lighting, signs, in accordance with the applicable development standards for the zone, as well as the hillside development standards. "Hillside development standards" mean the hillside development standards approved by the city council of the city of Temecula as now exist and as may from time to time be amended. "MSHCP" means the Western Riverside County Multi-Species Habitat Conservation Plan as adopted by the city council of the city of Temecula on December 16, 2003. "Peak" means the summit of a hill. "Restoration" means the process of repairing a disturbed site to replicate its natural condition. "Ridgeline" means a line connecting the highest elevation points of a ridge, running center and parallel to the long axis of the ridge. "Site" means the parcel on which development is proposed. "Slope analysis" means an analysis prepared by a California licensed land surveyor or civil engineer based on a topographic map with contour intervals not exceeding ten feet. D. Exemptions from Hillside Development Permit. The following are exempt from the provisions of this section: 1. Any development proposal calling for the construction of a structure in a ridgeline area having received approval, pursuant to the adopted regulations in effect at the time of approval, prior to enactment of the ordinance codified in this section shall be exempt; however, the requirements of this section shall be applied if an extension of time is requested; 2. Open space projects and regional or community trails on city of Temecula owned property; 3. City or other governmental projects that receive approval by the city council of the city of Temecula. E. Environmental Assessment Required. A hillside development permit processed under this section shall be a "project" for purposes of the California Environmental Quality Act. F. Application Requirements. In addition to the application requirements of Section 17.03.030 of the development code, all of the following shall be submitted with a hillside development permit application in the HR-SM zoning district: 1. A site plan drawn to scale by a California-licensed land surveyor or registered civil engineer, showing the location of all existing peaks, ridgelines, hills, hillsides and other significant landforms including rock outcroppings, all areas within two hundred feet of a peak or ridgeline, the location of all existing watercourses, the location of all existing vegetation including oak trees and the type and quantity thereof, the location of all existing and proposed agricultural areas, the location of all existing and proposed dwellings and the location of all existing and proposed accessory facilities; 2. A grading plan, including a blasting permit, if necessary, subject to the requirements of Title 18 of the Temecula Municipal Code; 3. A topographic map of the site, drawn to scale by a California-licensed land surveyor or civil engineer, showing all the items referenced in subsection (F)(1). The scale on the topographic map shall be no smaller than one inch equals two hundred feet with contour intervals not exceeding ten feet; 4. A slope analysis of the site showing the following slope categories: 0-15% grade, 16-20% grade, 21-25% grade and over 25% grade prepared by a licensed land surveyor or a registered engineer; 5. Underground utility plan; 6. A biological report for the site addressing the topics enumerated in subsection J of this section; 7. A cultural resources assessment prepared by a qualified archaeologist; 8. Photographs of the portion(s) of the site that would be disturbed taken from each corner of the site and from all vantage points deemed appropriate by the director of planning; 9. A proposed land disturbance plan showing and describing the portion(s) of the site that would be disturbed, and the nature and extent of the disturbance; 10. A proposed erosion and sedimentation control plan showing and describing interim and ultimate erosion and sedimentation control measures; 11. A proposed landscape and habitat restoration plan, including a restoration time schedule, showing and describing how the site would be landscaped and repaired and how the natural conditions of the site would be replicated. A qualified biologist shall prepare the habitat restoration plan; 12. A proposed architectural plan showing how primary and accessory structures would be constructed; 13. A proposed exterior lighting plan showing how primary and accessory structures, and landscaping would be illuminated; 14. A line of sight analysis, visual analysis, geologic study or any other requirement deemed appropriate by the planning director; 15. A fuel modification plan consistent with the General Guidelines for Creating Defensible Space adopted by the State Board of Forestry and Fire Protection, February 8, 2006 ("General Guidelines"), or the most current edition of the General Guidelines. G. Development Standards. The following development standards shall apply in the hillside residential-Santa Margarita (HR-SM) zone whenever a hillside development permit is required by this section: 1. Height. a. No dwelling, building or structure shall have more than two stories. b. On a level building pad, the maximum height of a dwelling, building or structure shall be thirty feet measured from the foundation. c. On a terraced building pad, the maximum height of a dwelling, building or structure shall be forty feet measured from the lowest finished floor level, excluding any basement areas. 2. Lot Area. a. The minimum lot size shall be ten acres in the HR-SM zone. b. Development in accordance with this section may occur on a lot smaller than ten acres in the HR-SM zone if the lot was legally created or previously existed on the effective date of the ordinance codified in this section, but no further subdivision of such a lot shall be allowed. 3. Land Disturbance. Land disturbance shall conform in all respects with the land disturbance plan approved by the director of planning. A land disturbance plan shall, at a minimum, meet the following requirements, but meeting these requirements does not guarantee approval of the plan. a. Areas situated within two hundred feet of a peak or ridgeline shall not be disturbed. b. Natural slopes having a twenty-five percent or greater grade shall not be disturbed. c. The horizontal distance between a natural or graded slope and a roof, or portion thereof, shall not be less than twenty feet. d. The vertical distance of a graded slope shall not exceed fifteen feet from the toe of the slope to the top of the graded slope, unless a five-foot bench is placed between two graded slopes and the bench is planted with vegetation similar to that growing on the portion(s) of the site that have not been disturbed. e. The maximum height of a graded slope, including required benching, shall not exceed thirty feet. f. The use of blasting for road construction or pad grading shall be strongly discouraged and alternate construction techniques shall be used if feasible. Site disturbance and grading shall be kept to a minimum. g. Land disturbance shall not exceed the following limitations: Land Disturbance Limitations Table HR-SM Zoning District Parcel/Lot Size | Maximum Area That May Be Disturbed 10 net acres or greater | 40,000 square feet Less than 10 acres | 10% of the lot area h. Land disturbance shall conform in all respects with the erosion and sedimentation control plan approved by the director of planning or public works. 4. Landscaping and Restoration. Landscaping and restoration shall conform in all respects with the landscaping and restoration plan approved by the director of planning. A landscaping and restoration plan shall be accompanied by a cash deposit equal to the cost of the revegetating all disturbed areas. The restoration plan shall be prepared by a biologist with expertise in habitat restoration. The director of planning shall retain this deposit until he or she is satisfied that revegetation has been successful, but in no event shall the director of planning retain the deposit for more than five years. Within the five-year period, the director shall have the authority to use the deposit to complete the required revegetation. 5. Architecture. Dwellings and accessory facilities shall conform in all respects with the architectural plan approved by the planning commission. 6. Exterior Lighting. Exterior lighting shall conform in all respects with the exterior lighting plan approved by the director of planning. An exterior lighting plan shall, at a minimum, meet the following requirements, but meeting these requirements does not guarantee approval of the plan: a. Lights shall not be located on the portion(s) of the site that have not been disturbed. b. Lights shall not be located closer than ten feet from any property line. c. Lights shall be fully shielded and directed away from areas deemed inappropriate by the director of planning. d. Walls and other architectural elements shall not be lighted for decorative purposes. e. Tennis and other sport courts shall not be lighted for any purposes. f. The maximum lighting intensity of the site shall not exceed two hundred fifty lumens when measured at any property line. 7. Energy Efficient Standards. Energy efficient standards shall be incorporated during the construction and operational phase of any structure permitted under this section: a. Construction of any structure for human habitation permitted under a hillside development plan shall be required to exceed Title 24 standards by a minimum of ten percent. b. All structures for human habitation shall incorporate sealed duct systems. c. All structures for shall incorporate fluorescent lighting where practical. d. "Energy Star" appliances shall be installed in all structures where applicable. e. All structures for human habitation shall incorporate high-albedo roofing. f. All structures for human habitation shall incorporate dual paned glass windows. g. All residential structures shall incorporate at least two of the following features to obtain a final building inspection: i. Spectrally selective or Low-E glass on all windows and doors; ii. Enhanced insulation which exceeds Title 24 standards by at least fifteen percent; iii. A landscape design that utilizes trees or other vegetation to shade the structure's sidewalks, patios, and driveways; iv. Solar water heaters; v. Photovoltaic systems to supply at a minimum eighty percent of the normal power needs of the structures proposed and existing based on an annual average. 8. Green Building. All residential structures will be required to incorporate one of the following features in order to obtain a final building inspection: a. Engineered and certified wood, which is harvested in a sustainable manner; b. Tankless water heaters; c. Cellulose attic insulation made from recycled materials; d. Floor coverings made from recycled or sustainable materials. 9. Environmental Protection. Projects within the HR-SM zoning district shall comply with all applicable mitigation measures adopted in conjunction with the pre-zoning and annexation of the property to the city. H. Hillside Design Standards. In deciding whether to approve a hillside development permit as required by this section and any subordinate land disturbance plan, erosion and sedimentation control plan, landscaping and restoration plan, architectural plan or exterior lighting plan, the director of planning shall certify that the plan complies with this section and the hillside design standards. Applicants are strongly advised to consider the hillside design standards in formulating the above-referenced plans. I. Relief from Development Standards. Notwithstanding the specific requirements set forth in this section, relief from the development standards may be granted concurrently with the processing of a hillside development permit in accordance with the following procedure: 1. An applicant may file an application for relief from certain development standards with the planning department. The application shall be filed on forms and submitted with information as required by the department. 2. Applications for relief from development standards shall be submitted to the planning department and shall be accompanied by the submittal requirements of subsections F and G of this section, and the following: a. Fees in accordance with the most recently adopted fee schedule; b. In certain cases, the directors of planning, building and safety, or public works may require the project applicant to provide additional studies, including, but not limited to, geological studies and/or a visual analysis of the project design either through a project simulation using computer aided three-dimensional modeling coordinated with photography showing before and after conditions or a scaled three-dimensional model showing before and after conditions. 3. The planning commission may approve relief from the requirements of subsection G if: a. The applicant demonstrates that the proposed alternative complies with and furthers the intent of this section; b. The applicant demonstrates that the proposed alternative provides a design solution that is equivalent to or better than the standards prescribed in this section for quality, effectiveness, durability, and safety. 4. The relief from development standards shall be heard at a public hearing of the planning commission. J. Conservation Required. Any project for which a hillside development permit is required by this section shall be designed to protect wildlife habitat areas, biological corridors, native plants and plant communities, and where practicable, support interconnected, contiguous, and integrated open space systems within an area, particularly when located contiguous to open space preserve areas. A hillside development permit shall be in compliance with the MSHCP. K. Hillside Cluster Development Option. 1. The purpose of the hillside cluster development option is to provide: a. Site planning and unity of design in harmony with the natural features and constraints of specific sites, and particularly on sites possessing unique or severe topographic or hydrologic features and biological resources; b. Protection of natural, historic and man-made elements of scenic, environmental or cultural significance; c. Design innovation; d. Flexibility of siting of structures and roadways; e. More cost effective development due to decreased grading and more efficient servicing of the development with utilities, roads and other essential services; f. Additional open space for private or community purposes; g. A preferred planning tool for the development of land within the HR-SM zone. 2. Definitions. "Cluster open space" means open space, either natural or functional, provided to compensate for lot size reductions from minimum lot size area requirements in the applicable zone. "Public open space" means open space owned by a public agency, such as the city of Temecula, or the Western Riverside County Regional Conservation Authority and maintained for scientific and biological values or in furtherance of the goals of the Western Riverside County Multi-Species Habitat Conservation Plan. "Scope" means the cluster development option is permitted in the HR-SM zoning district. 3. Planned Development Overlay Required. Proposed cluster developments must be processed pursuant to the requirements of the planned development overlay district as set forth in Chapter 17.22 of the development code. 4. Development Standards. a. Minimum Site Area. None in the HR zoning district. b. Overall Density. Greater than ten acres per dwelling unit in the HR zoning district. c. Minimum Lot Area Per Dwelling Unit. No minimum lot size, as may be approved by the hillside development plan. d. Minimum Setback Requirements. As may be approved by the hillside development plan. e. Minimum Distance Between Buildings. As may be approved by the hillside development plan. f. Utilities. Utilities shall be located within the development portion of the site wherever possible to reduce the future impact of maintenance and repair activities on cluster open space. g. Excess cut and fill material shall be disposed of in accordance with Title 18 of the Temecula Municipal Code. h. Roads. All streets and highways must have horizontal and vertical alignments consistent with an approved design speed, and roadway geometrics consistent with an approved design vehicle, as specified in the city of Temecula Road Design Manual. i. Landscaping. In accordance with subsection (G)(4) of this section and Chapter 17.32 of the Temecula Municipal Code. j. Exterior Lighting. Any exterior lighting shall conform to subsection (G)(6) of this section. k. Environmental Protection. Cluster developments within the HR-SM district shall comply with all applicable mitigation measures adopted in conjunction with the pre-zoning annexation of the property to the city. 5. Open Space Requirements. a. Cluster open space requirements: cluster open space shall be designed to save as much of the natural open space as feasible, but in no case shall the open space be less than ninety percent of the gross site area. b. Cluster open space ownership and control shall be only: i. As part of an individual, private lot with recorded open space covenants running with the land; ii. By the city of Temecula, as legally dedicated to and approved by the city council; iii. By the Western Riverside County Resource Conservation Authority; iv. By a qualified nonprofit conservation organization as deemed acceptable by the city. c. Cluster open space shall not include public or private streets, driveways, parking areas, channelized drainage ways, and disturbed, unvegetated areas.

( Ord. 08-15 § 7 ; Ord. 10-05 § 7 ; Ord. 23-11 , 11/28/2023 )

Ask a question about Temecula law

Corpus searches the Temecula sections it holds and shows the ones that match, with their citations. Free, no sign-in.