For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.22.188 — Supplemental development standards

Municipal Code, City of Temecula, California (legislation through Ord. No. 2026-04 adopted April 14, 2026) · Temecula Municipal Code § 17.22.188

Corpus is an independent public-information project, not the official City of Temecula website. Stable reference: corpuslaw.us/code/561b19b5-6e7a-40f9-940f-aae61e1fc9b2

§ 17.22.188: Supplemental development standards.

Permitted and conditionally permitted uses within PDO-7 shall comply with the development standards of the underlying public/institutional zoning district except as modified or augmented by the standards contained in this section. A. General. 1. All new development occurring within Planning Areas 1A, 1B, 1C and 1D shall be in substantial conformance with the Linfield Christian School master plan, provided that modifications of up to twenty percent of the estimated square footage of the individual or combined structures may be approved by the planning director. Minor modifications to the site location or number of new facilities may also be approved by the planning director. Major modifications to the overall scale, intensity or intended land uses within the planning areas shall be referred to the planning commission for approval. 2. All new development within Planning Areas 1A, 1B, 1C and 1D deemed to be in compliance with the Linfield master plan and design guidelines shall be subject to the administrative review process, pursuant to Section 17.05.020 of the Temecula Development Code. 3. Development proposals for faculty housing units within Planning Area 2 of PDO-7 shall be subject to the development standards of the medium density residential (M) zoning district, and will require review and approval of a development plan by the planning commission. The maximum number of residences to be developed in Planning Area 2 is twenty-six. 4. Development proposals for senior housing, assisted living, congregate care housing, skilled nursing or memory care facilities shall be permitted up to a maximum density of twenty-four units per acre within Planning Area 3A and adhere to the following minimum requirements: a. The net livable floor area square footage for senior housing units shall be as required in Section 17.10.020 except that assisted living units shall be a minimum of three hundred fifty square feet for studio/efficiency units; and memory care units shall be a minimum of two hundred fifty square feet for private units and three hundred fifty square feet for shared units. b. Senior housing for independent living and assisted living shall provide a minimum of sixty-eight square feet of private open space per unit, excluding units dedicated as guest units for visiting family members or other non-residents, and may be comprised of private outdoor patios, decks, porches, balconies, and yards. The combined common area and private open space shall be a minimum of two hundred square feet per unit and may include plazas, courtyards, gardens, recreational areas, putting greens, decks and patios. c. Single-story attached senior housing units shall provide a minimum of one hundred fifty square feet per unit of private open space which may be comprised of porches, patios, yards, and courtyards within the front and rear yard areas of the units. d. Memory care facilities shall provide a minimum of seventy-five square feet per unit of common area outdoor space. 5. There is no maximum lot coverage or floor area requirement for development projects within PDO-7, provided that the respective development standards for the use are met. B. Setbacks. 1. Landscape setbacks along the Pauba Road and Rancho Vista Road street frontages shall be an average of twenty feet, except for Planning Area 1B which shall be a minimum of five feet, due to the presence of the existing elementary school parking lot. The overall average front setback along either roadway shall be no less than twenty feet. 2. Sidewalks, pedestrian paths, paving, driveways and wrought iron or chain link fencing are permitted to be located within the landscaped setback area. C. Building Height. 1. Structures within Planning Area 1 shall not exceed two stories, or forty-five feet in height. Architectural projections such as mansards, towers and other design elements shall be permitted to extend an additional ten feet above the height of the building. Structures designed as split-level in order to accommodate the existing site grades are permitted up to a height of sixty feet as measured from the lowest grade. Any structures over forty-five feet in height shall be located a minimum of one hundred feet from the nearest exterior property line, and a minimum of two hundred fifty feet from the property line of any single-family residential structure. 2. Single-family residential and multifamily residential structures (with the exception of senior housing developments) shall not exceed two stories, or a maximum of thirty feet in height. 3. Multifamily senior housing, assisted living, congregate care housing, and convalescent housing structures within Planning Area 3A shall not exceed four stories, (excluding parking level) or sixty-five feet in height above the lowest grade, except that elevator shafts and stairwells may extend above the roof height. Any portion of a structure over forty-five feet in height shall be set back a minimum of one hundred and thirty feet from the property line of any single-family residential structure. D. Parking. 1. Parking requirements for assembly facilities within Planning Area 1 shall be considered as shared parking in conjunction with the standard spaces required under the development code for school parking. This determination applies to those assembly or special event facilities primarily used by the student population and faculty during the school day, or those facilities conducting events after school or in the evening hours when regular school parking is available. 2. In order to provide sufficient on-site parking in the case of a special event on campus, and to prevent potential overflow parking on surrounding public streets, temporary, special event parking may be provided on designated outdoor play courts in Planning Area 1. Such temporary parking areas shall be clearly identified, and cease operation at the conclusion of the special event. E. Landscaping and Fencing. Landscaping within parking lot areas shall be consistent with Section 17.24.050(H) of the Temecula Development Code, with the following exceptions: 1. Landscaped planters shall not be required within the interior of parking lots except for at the ends of each row of parking spaces, due to the need to insure clear visibility in parking areas for campus security purposes. 2. Required trees within the parking lot area shall be limited to the islands at the end of the parking rows, and within the landscaped areas at the perimeter of the parking lot. Trees shall be minimum fifteen-gallon containers, and may be spaced in a linear fashion around the perimeter or clustered. Trees shall be provided at a ratio of one tree for every four required parking spaces. Due to the extensive amount of existing mature trees within the district, and the internal nature of the parking lots within the landscaped setting, existing trees immediately adjacent to parking lots shall be included in the required count of parking lot trees. 3. Parking lot landscaping standards shall only apply to new or substantially redeveloped parking lot areas within the district. 4. Fencing for school facilities and outdoor recreation areas shall be exempt from the fence height requirements of Section 17.12.050 of the public/institutional district of the Temecula Development Code. Acceptable fencing materials include finished wrought iron or tubular steel, chain link, vinyl and decorative masonry.

( Ord. 03-09 § 3 ; Ord. 17-07 § 3 ; Ord. 23-09 , 11/14/2023 )

Ask a question about Temecula law

Corpus searches the Temecula sections it holds and shows the ones that match, with their citations. Free, no sign-in.