§ 9-4.4509 — Development standards
Thousand Oaks, California, Municipal Code (2026 S-78: current city legislation passed through March 31, 2026) · Thousand Oaks Municipal Code § 9-4.4509
Corpus is an independent public-information project, not the official City of Thousand Oaks website. Stable reference: corpuslaw.us/code/03d64edc-4329-4f02-a9e1-419874ce7683
Sec. 9-4.4509. Development standards.
(a) Limits on unit location. (1) No ADU shall be located within or encroach upon a natural slope steeper than twenty-five (25%) percent. (2) ADUs proposed on properties that are located within the Protected Ridgeline Overlay zone are subject to the following objective standards: (i) No new structure or addition to an existing structure shall be placed or constructed, no grading shall occur and, except as to meet fire clearance requirements, no native vegetation shall be removed within three hundred (300') feet horizontally or one hundred (100') feet vertically of the crest of a protected ridgeline unless the construction of the minimum allowed two (2) units of eight hundred (800') square feet or less is precluded, in which case the development must be sited at the lowest possible elevation. (3) No ADU created pursuant to this article shall be constructed, or require grading at the time of construction, within the protected zone (as defined by Sections 9-4.4202 and 9-4.4302) of a protected tree unless the construction of the minimum of eight hundred (800') square feet or less is precluded, in which case the protected tree may be encroached upon or removed if replaced onsite per the recommendations of a City Arborist, on a 1:1 basis, with a thirty-six (36") inch box Quercus agrifolia Live Oak or Quercus lobata Valley Oak. If the replacement tree(s) is unable to be successfully sited onsite, an in-lieu fee will be required per Resolution 2010-014, as may be amended. (b) Conversion within or attached to primary dwelling accessory dwelling units. (1) The maximum size is eight hundred fifty (850') square feet of interior livable space or fifty (50%) percent of the existing primary dwelling’s total floor area, whichever is greater. The minimum size is the same as an efficiency dwelling. (2) The side and rear setbacks are four (4) feet from the property line for new enclosed square footage for the attached ADU. The front setback is the same as required for the primary dwelling. (3) The maximum height is twenty-five (25') feet, or the height limitation as detailed in Section 9-4.2501 that applies to the primary dwelling, whichever is lower. (4) A full kitchen and sanitation facilities are required and must be separate from the primary dwelling. (5) Attached and converted ADUs must share a minimum of ten (10') feet of the wall of the main single-family home. No internal connection is permitted. (c) Detached accessory dwelling units. (1) The maximum size of a detached ADU is one thousand (1,000') square feet of interior livable space. (2) The side and rear setbacks are four (4') feet from the property line. The front setback is the same as required for the primary dwelling. (3) The maximum height is sixteen (16') feet. (4) The maximum height can be increased to eighteen (18') feet for a detached accessory dwelling unit on a lot with an existing or proposed single-family dwelling unit that is within one-half (1/2) mile walking distance from a major transit stop or a high-quality transit corridor, as those terms are defined in Section 21155 of the Public Resources Code. (5) The maximum height can be increased by two (2) feet to accommodate a roof pitch that is aligned with the roof pitch of the primary dwelling unit. (6) Detached ADUs may not be attached to the existing single-family dwelling by breezeways or any similar structure and must be separated from any proposed or existing structure by a minimum of six (6') feet as measured from the face of wall to the nearest face of wall. (d) Accessory structures. (1) No accessory structure shall be attached to a detached ADU unless the combined total floor area of the accessory structure and ADU does not exceed the allowable size of the ADU. (2) Where a detached ADU is proposed with an attached garage, the garage portion shall be no larger than four hundred (400') square feet. (3) The size of any proposed patio cover(s) and/or covered porch(s) will be cumulatively limited to ten (10%) percent of the square footage of the proposed ADU. The patio cover and/or covered porch square footage is not to be included in the total livable space calculation in Section 9-4.4509(c)(1). (4) An ADU attached to an accessory structure shall not have internal access to the accessory structure. (e) Conversion of existing structures. (1) A portion of an existing legally established single-family dwelling, or all or a portion of an accessory structure, may be converted to an ADU, even if such structure does not comply with the otherwise applicable height and setback requirements. (2) An accessory structure may be demolished and reconstructed in the same location and to the same dimensions and may be fully or partially converted to a detached ADU, even if such structure does not comply with the otherwise applicable height and setback requirements. (3) An accessory structure, including a demolished and reconstructed structure, that is being fully or partially converted to a detached ADU, may be expanded by up to one hundred fifty (150') square feet to accommodate ingress and egress. Any new construction proposed for ingress/egress must be setback from the side and rear yards at least four (4') feet and have a maximum height that matches the accessory structure or sixteen (16') feet, whichever is less. (4) Attached ADUs converted from the existing primary dwelling can add one hundred fifty (150') square feet for the purpose of ingress and egress, not to exceed the square footage allowance. Any new construction proposed for the purposes of ingress/egress must be setback from the side and rear yards at least four (4') feet and have a maximum height that matches the existing structure or sixteen (16') feet, whichever is less. (5) Where an attached garage that provides the required parking for a primary dwelling is partially converted to an ADU, the remaining space shall continue to be utilized for parking if physically feasible. If it is not feasible for the remaining space to be used for parking, the remaining space shall be utilized for storage or similar non-habitable use for the primary dwelling. (§ 2, Ord. 1732-NS, eff. November 22, 2024, as amended by Part 4, Ord. 1735-NS, eff. April 25, 2025, and Part 1, Ord. 1747-NS, eff. April 10, 2026)
Ask a question about Thousand Oaks law
Corpus searches the Thousand Oaks sections it holds and shows the ones that match, with their citations. Free, no sign-in.
