For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 72.2.10 — Sewer connection requirements

Municipal Code, City of Torrance, California · Torrance Municipal Code § 72.2.10

Corpus is an independent public-information project, not the official City of Torrance website. Stable reference: corpuslaw.us/code/965aa2a1-867a-4f86-aafb-af170b9a8a51

§ 72.2.10: Sewer connection requirements.

It shall be unlawful for any person to make or to maintain, or to cause to be made or maintained, any connection with any public sewer of the City, until a permit therefor shall have first been obtained from the Street Superintendent, or to make, or cause to be made, any such connection pursuant to any such permit at any place other than that designated therein. Every connection made with any public sewer of the City shall be made in the following manner, and with such materials as are hereinafter set forth: All pipe shall be first class, vitrified, salt glazed, socket pipe or standard cast-iron soil pipe, not less than six (6) inches in internal diameter for that portion extending from the street sewer to the property line, and not less than four (4) inches in internal diameter for that portion extending from the property line to the house or building for house connection sewers serving twenty (20) persons or less, and not less than six (6) inches in internal diameter for all portions of house connection sewers serving more than twenty (20) persons. A cleanout shall be placed in every house connection sewer at the junction of the soil pipe at the building and at all changes in alignment and grade. The cleanout shall be made by inserting a Y branch in the line with a cap of the same material as the house connection sewer pipe tightly cemented in the bell end of the portion of the "Y" branch which will be used to gain access to the connection. All vitrified clay pipe shall be laid upgrade on an unyielding foundation and with the socket ends of the pipe upgrade. A narrow gasket of oakum or hemp shall be caulked into each joint, after which the mortar shall be introduced therein. The entire annular space in all pipejoints between the exterior of the spigot and the interior of the socket shall be completely and carefully filled with cement mortar, which shall be composed of one (1) part cement and two (2) parts sand. The connection shall be watertight when completed. When the condition of the trench is such that it is impossible to secure a watertight cement mortar joint, a sewer joint compound which shall meet the requirements of the standard specifications for public sewers referred to shall be used. All joints of standard cast iron soil pipe shall be made with pig lead and oakum and shall be thoroughly caulked. The grade shall be straight from the property line to the public sewer and shall have a wall of not less than one (1) foot in fifty (50) feet towards the public sewer, except where otherwise permitted by special permit in writing from the Street Superintendent. Vitrified clay piping shall not be placed closer than twelve (12) inches to the exterior wall of any building or closer than twelve (12) inches to the surface of the ground at any point of its course. Where laid within the limits of a public street, no connection shall be laid less than three (3) feet below the established grade of the same or below the surface, where no grade is established, except by a special permit in writing from the Street Superintendent. No sewer connection shall be covered or concealed in any way until it has been inspected and approved by the Street Superintendent. All house connection sewers outside of any buildings shall be tested for leaks or defects in that portion extending from the property line to the upper terminus by a standing test, which shall consist of filling the line with water, the level of which shall be at least four (4) inches above the top of the upper terminal end of such house connection sewer. No test shall be made until at least twenty-four (24) hours after the joints in such pipe have been made, where such joints are cemented joints. Where by reason of excessive fall in such house connection sewers, the static pressure will exceed four (4) pounds per square inch, the line may be tested in sections, such that no section will be subjected to a greater pressure than four (4) pounds. No house connection sewer shall be approved if any portion thereof, including any fitting, material, work or construction fails to withstand such test without leaking at any point. It shall be unlawful for any person to connect or cause to be connected, any sewer which has been, or may hereafter be constructed in any street, alley, right-of-way or other public place prior to the dedication and acceptance of such street, alley, right-of-way or other public place by the City Council on behalf of the public, with any public sewer of the City, unless such sewer first mentioned shall have been laid under the supervision and to the satisfaction of the Street Superintendent, or of the Chief Engineer of the County Sanitation Districts and in accordance with the standard specifications above mentioned, and in accordance with plans and profiles approved by the City Engineer or the Chief Engineer.

Ask a question about Torrance law

Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.