For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 815.2.090 — Engineering analysis and design

Municipal Code, City of Torrance, California · Torrance Municipal Code § 815.2.090

Corpus is an independent public-information project, not the official City of Torrance website. Stable reference: corpuslaw.us/code/ad687b7f-9caf-49c2-b515-ce72aceaa8c4

§ 815.2.090: Engineering analysis and design.

a) Wall Anchorage System for Rigid-Wall-Flexible-Diaphragm buildings shall be evaluated or strengthened in accordance with ASCE 7. The anchorage shall provide a direct connection capable of resisting 75% of the forces specified in ASCE 7 and the Seismic Design Guidelines. Exceptions: (1) Existing walls need not be evaluated or retrofitted for bending between anchors. (2) Work required by this chapter need not consider shrinkage, thermal changes, or differential settlement. As an alternate, Wall Anchorage System for Rigid-Wall-Flexible-Diaphragm buildings shall be evaluated or strengthened in accordance with ASCE 41 and the Seismic Design Guidelines for seismic performance levels and hazards, indicated in Table C. TABLE C: ASCE 41 Criteria Risk Category | Hazard | Structural Performance Level I and II | BSE-2E | Collapse Prevention (S-5) III | BSE-2E | Limited Safety (S-4) IV | BSE-1E | Immediate Occupancy (S-1) BSE-2E | Life Safety (S-3) ASCE 41 and ASCE 7 criteria shall not be mixed. b) Geologic site hazards. Mitigation of existing geologic site hazards such as liquefiable soil, fault rupture or landslide is not required for compliance with this chapter. c) Additional requirements for wall anchorage systems. Requirements for wall anchorage systems, including but not limited to minimum spacing and combination of anchor types, shall be provided as specified by ASCE 7, or ASCE 41, and the Seismic Design Guidelines. d) Development of anchor forces into the diaphragm. Development of the required anchorage forces into roof and floor diaphragms shall be provided as specified by ASCE 7, or ASCE 41, and the Seismic Design Guidelines. e) Anchorage at pilasters. If pilasters are present, their anchorage shall comply with the requirements of ASCE 7, or ASCE 41, and the Seismic Design Guidelines. f) Anchorage at interior walls. Existing interior reinforced concrete or reinforced masonry walls that extend to the floor above or to the roof diaphragm shall be anchored for out-of-plane forces per ASCE 7, or ASCE 41, and the Seismic Design Guidelines. g) Mezzanines. Existing mezzanines relying on reinforced concrete or reinforced masonry walls for vertical or lateral support shall be anchored to the walls for the tributary mezzanine load. Exception: Existing mezzanines that have independent lateral and vertical support need not be anchored to the walls.

Ask a question about Torrance law

Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.