§ 92.11.4 — Access for fire fighting equipment, multiple family dwellings

Municipal Code, City of Torrance, California · Torrance Municipal Code § 92.11.4

Corpus is an independent public-information project, not the official City of Torrance website. Stable reference: corpuslaw.us/code/3d064cc3-09d8-4db5-b50d-8c2a98f6e340

§ 92.11.4: Access for fire fighting equipment, multiple family dwellings.

Interior fire hydrants shall be installed for every apartment building or group of apartment buildings of three (3) stories or less, when adequate Fire Department access is not provided by driveways of not less than twelve (12) feet in width with an overhead clearance of not less than twelve (12) feet. Fire hydrants may be of two (2) types, wet or dry. a) Wet fire hydrants: 1) Wet fire hydrants shall have at least two (2), two and one half (2-½) inch Fire Department outlets. Each outlet shall have a shutoff valve. 2) Wet fire hydrants may be connected to the domestic water supply. 3) Wet hydrants shall have a discharge capacity of not less than five hundred (500) gallons per minute in addition to the domestic water requirements. 4) Wet hydrants shall be so located that the area protected by the hydrants shall be not greater than a travel distance of two hundred (200) feet. EXCEPTION: Fire Department authorities may modify the requirements of Section a-4) depending upon the accessibility for emergency purposes. b) Dry fire hydrants or dry standpipe systems: 1) Dry fire hydrants shall have at least two (2), two and one-half (2-½) inch Fire Department outlets. Each outlet shall have a shutoff valve. 2) Dry hydrants shall be supplied by a pipe of sufficient size to discharge a minimum of five hundred (500) gallons per minute. 3) A Fire Department connection shall be located on the street in front of the building to supply the dry hydrants. 4) Dry hydrants shall be so located that the area protected by the hydrants shall be not greater than a travel distance of two hundred (200) feet. EXCEPTION: Fire Department authorities may modify the requirements of Section b-4) depending upon the accessibility for emergency purposes. 5) Dry hydrant system components shall be installed to the requirements of the National Fire Protection Association, Pamphlet 23.

[Added by Ord. 1937 ; Ord. 1938 ]

Ask a question about Torrance law

Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.