For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 98.1.5 — Development standards

Municipal Code, City of Torrance, California · Torrance Municipal Code § 98.1.5

Corpus is an independent public-information project, not the official City of Torrance website. Stable reference: corpuslaw.us/code/7b306059-c9b7-4468-8e4a-ab3ce404dc8b

§ 98.1.5: Development standards.

a) Landing areas shall, as far as practicable, be aligned with regard to prevailing winds and/or air turbulence. b) The area used for landing shall be surfaced with material that will be free of dust, loose organic or inorganic materials, and particles of concrete which may be blown about by the down-blast of air of the rotor or rotors. c) Touchdown areas shall be surrounded by a fence or wall at least four (4) feet high and constructed in such a manner as to deflect the horizontal wind velocities caused by the rotation of the rotor blades. d) In addition, the following safety precautions shall be taken: 1) Rooftop facilities: A) On all touchdown or landing areas, whether elevated or flush with the roof, provisions shall be made for collecting volatile substance which may be spilled in event of any emergency. Separator or clarifier tanks for collecting spilled volatile substance shall be installed under approval and supervision of the Torrance Fire Department. B) The rooftop shall have at least two (2) conforming exits and they shall be located in such a manner as to permit safe exit from the roof area in the event one of the exits is blocked. C) A wind indicating device shall be installed. A flag, banner or similar device shall be acceptable. D) Two or more wet standpipes shall be provided and equipped with 1-½ inch rubber lined fire hoses not over one hundred (100) feet in length. Hoses shall be equipped with combination fog nozzles. Sufficient pressure shall be available to afford a good fog pattern. Hose cabinets or racks shall be located near the separate exits. Standpipe outlets shall be so located that all portions of the roof area shall be within one hundred twenty (120) feet of the outlet. E) Two (2) fire extinguishers of a least 16BC rating shall be provided, and be located remotely from each other. F) No rooftop obstructions which may be difficult to see from the air shall be permitted within the required glide slope. G) Such lights as are installed to illuminate the touchdown pad shall be directed onto the touchdown pad only, and in such a manner that the light rays cannot interfere with the helicopter pilot’s vision or with other aircraft flying within the area of the landing facility. H) No person shall be permitted in the general landing area in any location where any portion of his body higher than the touchdown area surface while landing or takeoff operations are underway. I) Approved means of communication such as telephone, radio, fire alarm box, or signaling device shall be provided adjacent to the landing area. J) If the roof has no parapet wall, a substantial fence shall be provided around the perimeter of the roof to insure the safety of all persons. K) Rooftop facilities shall be built in accordance with the City Building Code as applicable for structural and fire protective requirements. 2) Ground Level Helistops and Heliports for Helicopters: A) All installed light shall illuminate and be directed onto the touchdown pad only, and in such a manner that the light rays cannot interfere with the pilot’s vision. B) A wind indicating device shall be installed. A flag, banner, or similar device shall be acceptable. C) Unauthorized persons shall not be permitted in the general landing area during flight operations. D) Two (2) fire extinguishers of at least 16BC rating shall be provided and be located remotely from each other. E) Where buildings or structures in proximity to the landing area present a fire exposure hazard, there shall be provided at least two (2) 1-½ inch wet standpipe outlets equipped with 1-½ inch fire hoses not over one hundred (100) feet in length, and a combination fog nozzle. F) Approved means of communication such as telephone, radio, fire alarm box or signaling device shall be provided adjacent to the landing area. e) A detailed sire plan shall be submitted showing all safety precautions, parking area layout, landscaping along the street frontages, type and size of aircraft proposed for use, and approach and departure lanes. f) Landing Markers. All landing markers shall conform to those recommended by the Federal Aviation Agency (FAA). 1) Rooftop Markings. The bulls eye type of marker shall be used for rooftop helistops. The painted border line marking the takeoff and landing area may be a solid or broken line. The outer circle of the bulls eye shall be inscribed within the touchdown area, whose sides should be tangent to the circle. The dimensions of the bulls eye marker shall be determined by the size of the touchdown area. Each rooftop heliport shall be painted with the bulls eye, by means of numerals not less than two (2) feet in height, the maximum gross weight in thousands of pounds of the equipment which the roof is stressed to accept. 2) Ground Markers. The day marker shall be substantially in the form recommended by the Federal Aviation Agency (FAA). g) The Touchdown Area. The touchdown area (as opposed to the landing area) for helicopters under 3500 pounds shall have a minimum dimension of twenty (20) by twenty (20) feet. Touchdown areas for helicopters over 3500 pounds shall be a minimum of 1-½ times the diameter of the rotor blades.

Ask a question about Torrance law

Corpus searches the Torrance sections it holds and shows the ones that match, with their citations. Free, no sign-in.