For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.11.030 — On-Site Vehicle Parking Requirements

Code of Ordinances, City of Upland, California (eCode360 UP5026 version 2025-09-22: Includes legislation through Ord. No. 2002 adopted September 22, 2025) · Upland Zoning Code § 17.11.030

Corpus is an independent public-information project, not the official City of Upland website. Stable reference: corpuslaw.us/code/87b25293-6ce4-4d09-ad6c-ba59c2969687

§ 17.11.030: On-Site Vehicle Parking Requirements.

A. Parking Spaces Required. All land uses shall provide on-site parking as required in Table 17.11-1 (On-Site Parking Requirements). TABLE 17.11-1 ON-SITE PARKING REQUIREMENTS Land Use | Required Number of Spaces [1] Residential Uses Boarding House | 1 per two beds Duplex Home | 2 per unit Elderly and Long-Term Care | 1 for each 3 beds the facility is licensed to accommodate Emergency Shelters | 1 per 300 square feet of habitable floor area, or sufficient to serve the parking demand determined in a parking study Family Day Care Small (6 or fewer) | 2 within a garage Large (7–12) | 1 for the single-family dwelling plus 1.5 per 1,000 sq. ft. Guest House | 1 or 2 bedrooms: 1 per unit; 3 or more bedrooms: 2 per unit Live/Work Units | 1.5 for up to 2,500 sq. ft. of floor area; plus 0.5 additional for every additional 500 sq. ft., or fraction thereof, of floor area above the first 2,500 sq. ft. Mobile Home/Manufactured Home | 2 for each mobile home (tandem parking allowed in an attached carport); plus 1 guest space for every 5 mobile homes [senior mobile-home parks are allowed parking concessions per Chapter 17.17 (Density Bonus Program)] Multi-family Residential | Studio and 1 bedroom units: 1 for each unit in a garage;2 bedroom: 2 for each unit in a garage;3 or more bedrooms: 2.5 for each unit, including 2 in garage;Guest parking: 3-50 units: 1 per 4 units; 51-100 units: 1 per 5 units; 100 + units: 1 per 6 units Residential Care Facilities Small (6 or fewer) | 2 within a garage Large (7 or more) | 2 within a garage; plus 1 per 300 sq. ft. of office and other non-residential areas Second Dwelling Unit | 1 space in addition to that required for a single-family unit Senior Citizen Housing | 1 for each unit with half the spaces covered, plus 1 guest parking space for each 10 units Single-Room Occupancy Units | 1 per unit plus 1 guest space for every 3 units Single-Family Dwelling | 2 within a garage Skilled Nursing Facilities | 1 per 3 beds Supportive and Transitional Housing Small (6 or fewer persons in a dwelling unit) | 2 per dwelling Large (7 or more persons in a dwelling unit) | 1 per 3 beds; plus 1 per 300 sq. ft. of office and other non-residential areas Community Uses Airport or Aircraft Land Field | 2 per 1,000 sq. ft. of floor area of enclosed passenger terminal area Cemeteries | 1 per 60 sq. ft. of assembly area Community Assembly | 1 per 300 sq. ft. of floor area Correctional Institutions and Facilities | As determined by a parking needs assessment Cultural and Religious Facilities and Institutions | 1 per 4 fixed seats, or 1 per 60 sq. ft. of assembly area for uses without fixed seats, or 1 per 500 sq. ft. of non-assembly area Child Care/Day Care Centers | 1 per 350 sq. ft. of floor area Post-Secondary Educational Institution or Trade Schools | 1 per 35 sq. ft. of instructional area (GFA) Equestrian Establishments | 1 per 300 sq. ft. within stable; plus 1 per 3 animal stalls Emergency Shelters | 1 per 8 beds; plus 1 per 300 sq. ft. of office or other non-residential area Funeral Homes/Mortuaries | 1 per 5 fixed seats or 54 ft. of bench seating; or 1 per 35 sq. ft. of assembly area where there are no fixed seats Golf Courses and County Clubs | 1 per hole; plus 1 per 300 sq. ft. of office or other non-residential area Hospital | 1 for each patient bed the facility is licensed to accommodate; plus 1 for each 400 sq. ft. of office area; plus required spaces for accessory uses as determined by the Development Services Director Libraries | 1 for each 500 sq. ft., plus 1 for each official vehicle Office, Governmental | 1 for each 500 sq. ft. Parks and Playgrounds Neighborhood Park (less than 3 acres) | 3 for the first acre of park area; plus 2 for each additional acre Community Park (greater than 3 acres) | 5 per acre; plus additional spaces per each major facility Athletic Field | 5 to 8 per acre depending on spectator seating accommodations Swimming Pool (indoor and outdoor) | 1 for each 100 sq. ft. of swimming pool area Picnic Area | 1 per picnic table; or 3 for 1 acre of picnic area Botanical or Horticultural Displays | 1 per 300 sq. ft. of office area Public Safety Facilities | 1 per 1,000 sq. ft.; plus 2 additional for station vehicles Private Educational Institutions (K–12) | 1 per classroom; plus 1 per 5 fixed seats in auditorium, gymnasium, or similar public assembly facility; or 1 per 35 sq. ft. GFA of assembly area where there are no fixed seats.For private high schools: 1 per classroom; plus 1 per 5 students based on maximum student capacity. Commercial Uses Adult Businesses | 1 per 50 sq. ft. Animal Care, Sales, and Services | 1 per 300 sq. ft., with a minimum of 4 spaces Art Gallery | 1 for each 500 sq. ft. Automobile/Vehicle Sales and Services Automobile Broker/Wholesaler | 2 per 1,000 sq. ft. Automobile Repair, Automobile Accessory/Equipment Installations | 2 per 1,000 sq. ft. Automobile Rental | 1 per 600 sq. ft. of show room floor area Automobile Service Station, Smoke Check Testing | 1 for each 250 sq. ft. Automobile Storage Lots/Towing and Impound | 2 per 1,000 sq. ft. Automobile/Vehicle Sales and Leasing | 1 per 600 sq. ft. of show room floor area Automobile/Vehicle Washing (full service) | 10 spaces or 3 times internal washing capacity, whichever is greater; plus additional parking required for drying or vacuum areas; plus 100 lineal ft. for stacking Automobile/Vehicle Washing (self service) | 4 spaces, plus additional parking for drying/vacuum areas; plus 20 ft. in front of each bay for stacking Banks and Financial Institutions | 1 for each 300 sq. ft. Bicycle Rental, Sales and Repair | 2 per 1,000 sq. ft. Dry Cleaners Drop-off | 1 per 250 sq. ft., minimum of 4 Processing | 2 per 1,000 sq. ft. Eating and Drinking Establishments Bars/Nightclubs/Lounges | 1 per 300 sq. ft. Restaurants, Full-Service, Limited-Service, Take-out | 1 per 100 sq. ft. Restaurants, with Drive-Through Facilities | 1 per 200 sq. ft. Restaurants, with Live Entertainment/Dancing | 1 per 200 sq. ft. With Outdoor Eating Areas | Greater of 1 per 200 sq. ft. of outdoor seating area or 1 for every 3 seats Food and Beverage Sales Bakery | 1 per 200 sq. ft. Catering Businesses | 1 per 300 sq. ft. General Market/Convenience Store (less than 10,000 sq. ft.) | 1 per 200 sq. ft. Supermarket (10,000 sq. ft. or more) | 1 per 200 sq. ft. Fire Arms Clubs and Establishments | 1 per target area or as determined by a parking demand study Health/Fitness Facility | 1 per 100 sq. ft. Live Performance | 1 per 50 sq. ft. Lodging Bed and Breakfast | 2 for owner/manager; plus 1 additional for each guest room Hotels and Motels | 1 for every 2 guest rooms for the first 40 guest rooms, and 1 for every 4 guest rooms over the initial 40 guest rooms Movie Theater | 1 per 5 seats Nursery (wholesale, retail) | 1 per 300 sq. ft. of enclosed retail; plus 1 per 1,000 sq. ft. of outdoor display/storage area Outdoor Storage | 1 per 2,000 sq. ft.; plus one per 350 sq. ft. of office area Personal Services, Massage Therapy, Psychics, Pawn Shops, Tattoo Parlors | 1 for each 250 sq. ft. Public Storage | 1 per 100 storage units or 5 spaces, whichever is greater Recreational Vehicle Storage and Parking | 2 per 1,000 sq. ft. Recycling Facilities | 1 per 1,000 sq. ft. of floor area Retail Stores, General Merchandise | 1 for each 250 sq. ft.; plus 1 for each 600 sq. ft. of storage area, and 1 for each company vehicle; plus 1 for each 1,000 sq. ft. of outdoor display area. Secondhand Goods Store | 3 per 1,000 sq. ft. Senior Housing | 1 for each unit, with half the spaces covered; plus 1 guest parking space for each 10 units. Smoke Lounge/Tobacco Shop/E-Vape/Hookah | 1 for each 300 sq. ft. of service area Swap Meetings and Flea Markets | 1 per 250 sq. ft. of affected land area Warehousing | 1 per 1,000 sq. ft. of warehouse area, plus 1 per 300 sq. ft. of office use Office/Professional Uses Business Support Services | 3 per 1,000 sq. ft. Office | 1 for each 400 sq. ft. Medical or Dental Laboratory | 1 for each 300 sq. ft. Medical or Dental Office | 1 per 250 sq. ft., with a minimum of 4 spaces Urgent Care Facility | 1 per 150 sq. ft. Mixed Use Studio and One-Bedroom Units | 1 per unit; plus 0.25 guest spaces per unit Two or More Bedrooms | 1.5 spaces per unit; plus 0.25 guest spaces per unit Office | 1 per 450 sq. ft. Commercial | 1 per 400 sq. ft. Restaurant | 1 per 250 sq. ft. Industrial | 2 per 1,000 sq. ft. for the first 25,000 sq. ft.; 1.5 per 1,000 sq. ft. for portion of building 25,000—50,000 sq. ft.; 1.25 per 1,000 sq. ft. for portion of building greater than 50,000 sq. ft. Agricultural/Natural Resource And Industrial Uses Industrial Light Industrial | 1 per 500 sq. ft. of industrial/manufacturing area Heavy Industrial (general manufacturing, industrial and processing uses) | 2 for each 1,000 sq. ft. for the first 25,000 sq. ft., and 1 for each 1,000 sq. ft. thereafter. Up to 20% of accessory office uses shall be permitted at this ratio. The parking requirements for additional office space shall be calculated separately. Development of Natural Resources/Surface Mining and Reclamation/Processing | 1 per 1,000 sq. ft. of floor area for all habitable buildings associated with the use, and 3 per 1,000 sq. ft. of the remaining area Animal Grazing, Beekeeping, Crop Cultivation | 1 per 1,000 sq. ft. of floor area for all habitable buildings associated with the use Telecommunication and Utilities Telecommunication Facilities | 1 per 350 sq. ft. of floor area for habitable buildings Utilities | 3 per 1,000 sq. ft. of office area; plus 1 per vehicle required to service each facility Note: [1] | All square footages shall be gross square footage. B. Compact Parking Stalls. In parking areas or garages containing 10 or more spaces for other than dwelling uses, up to 40%of the total required parking spaces and 100% of the non-required parking spaces may be compact. For dwelling uses, all parking stalls in excess of two stalls per unit may be compact. Required guest parking spaces may also be compact spaces. C. Tandem Parking (Vertical or Horizontal). Tandem parking may be may be allowed for multi-family projects and the residential component of mixed-use projects subject to the following requirements and Section 17.11.090 of this chapter. 1. Up to 30 percent of the total off-street parking spaces provided may incorporate tandem parking. For projects utilizing the density bonus provisions of Chapter 17.17 (Density Bonus), up to 50 percent of the required parking spaces may be accommodated by either vertical or horizontal tandem parking as defined in Part 7 (Definitions: Tandem Parking). 2. Both tandem spaces shall be assigned to the same dwelling unit. D. Carports. Carport parking spaces shall only be allowed for non-required parking spaces. E. Guest Parking Spaces (Residential). Residential guest parking spaces may be covered or uncovered. F. Unlisted Uses. 1. The Development Services Director shall determine on-site parking requirements for uses not listed in Table 17.11-1 (On-Site Parking Requirements). 2. On-site parking requirements for unlisted uses shall be based on the parking requirements of similar uses in Table 17.11-1 (On-Site Parking Requirements). 3. The Development Services Director may require the preparation of a parking demand study by a qualified, licensed traffic engineer approved by the City to determine the parking requirement for unlisted uses. G. Unknown Uses (Non-Residential). 1. The Development Services Director shall determine on-site parking requirements for non-residential "shell" structures with no identified tenants. 2. Parking requirements shall be based on anticipated tenants for the structures, as determined by the Development Services Director. H. Multiple Uses. If more than one use is located on a site, the number of required on-site parking spaces and loading spaces shall be equal to the sum of the requirements calculated separately for each use unless a reduction is approved pursuant to Subsection J (Parking Reductions). I. Mixed-Use Development. The required numbers of on-site parking spaces for mixed-use districts are stated in Table 17.11-1 (On-Site Parking Requirements). Additional parking reductions may also be granted through the provision of shared parking facilities pursuant to Subsection J (Parking Reductions). J. Parking Reductions. The review authority shall grant a reduction in required parking as specified in Table 17.11-1 (On-Site Parking Requirements) when the following conditions exist: 1. Shared Parking. Where a shared parking facility serving more than one use will be provided, the total number of required parking spaces may be reduced, if the review authority finds that: a. The peak hours of use will not overlap or coincide to the degree that peak demand for parking spaces from all uses will be greater than the total supply of spaces; b. The proposed shared parking provided will be adequate to serve each use; c. A parking demand study prepared by an independent traffic engineering professional approved by the City supports the proposed reduction; and d. In the case of a shared parking facility that serves more than one property, a parking agreement has been prepared consistent with the provisions of off-site parking facilities. K. Parking Study. The Development Services Director may require a parking demand study if, in his or her opinion, the proposed development does not provide adequately for on-site parking needs, may adversely affect off-site traffic patterns, or is unique and does not fall within the identified parking requirements. The parking study shall be processed in conjunction with the applicable development application. 1. Low Demand. The number of parking spaces may be reduced if the use will not utilize the required number of spaces due to the nature of the specific use, as demonstrated by a parking demand study prepared by a qualified, licensed traffic engineer approved by the Development Services Director. 2. Transportation Management Plan. The number of required parking spaces may be decreased by up to 20 percent, subject to Planning Commission approval of an alternate commute mode awareness plan. L. Transit Accessibility. For any land use except single-unit and duplex development, if any portion of the lot is located within ¼ mile of a transit stop with regular, scheduled service during the weekday hours of 7:00 a.m. to 9:00 a.m. and 5:00 p.m. to 7:00 p.m., the number of required parking spaces may be reduced by 20 percent of the normally required number of spaces. This parking reduction does not apply in the mixed-use districts because parking requirements for these districts already reflect transit accessibility.

Ask a question about Upland law

Corpus searches the Upland sections it holds and shows the ones that match, with their citations. Free, no sign-in.