For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 9.40.090 — Mining industry allowed noise levels for residential property

Code of Ordinances, City of Upland, California (eCode360 UP5026 version 2025-09-22: Includes legislation through Ord. No. 2002 adopted September 22, 2025) · Upland Municipal Code § 9.40.090

Corpus is an independent public-information project, not the official City of Upland website. Stable reference: corpuslaw.us/code/1fc6f5d1-c8cd-4219-a718-ee015a89704a

§ 9.40.090: Mining industry allowed noise levels for residential property.

A. Exemptions. This section shall supersede all the provisions of Sections 9.40.040 and 9.46.070 relative to allowed noise for mining industry. B. Allowed Levels. The allowed maximum exterior average sound level in any hour at any property zoned for residential use shall be as follows: Mining Industry Use and Days Allowed | Times | Allowed Levels Monday—Friday: Quarry/plant | 6 a.m.—6 p.m. | 55 dB(A) Construction material manufacturer | 5 a.m.—6 p.m. | 55 dB(A) Saturday: Quarry/plant | 7 a.m.—3 p.m. | 55 dB(A) Construction material manufacturer | 5 a.m.—3 p.m. | 55 dB(A) All Times: Quarry/plant | | 45 dB(A) Construction material manufacturer | | 45 dB(A) C. Exceptions. Exceptions may be granted in the event of a proven emergency situation or required by a public agency and written authorization is obtained from the city manager or designee prior to quarry, plant or construction material manufacturer operations being conducted. The maximum exterior sound level at any property zoned for residential use shall not exceed 55 dB(A) during such exception. D. Measurement Parameters. 1. Measurements shall be made to the one-tenth decibel, but shall be reported to the integer value. Values of 0.1 to 0.4 shall be rounded down to the lower integer. Values of 0.5 to 0.9 shall be rounded up to the higher integer. 2. If measurements are made for more than one hour, the subsequent measurements shall be made on one hour increments. For a series of one hour measurements, compliance shall be determined by the highest average hourly reading. Measurements shall be started on the hour and ended on the hour. 3. Measurements of less than one hour, extrapolated to one hour shall not be used to determine compliance or violation. 4. Measurements will be made on the "A" weighted scale and a slow response. E. Measurement Location. Exterior measurements shall be at locations on residential property that are considered accessible for normal and usual outdoor human activity and which are intended and used for such purposes. The receptor shall be placed at five feet above the ground surface and 10 feet from any reflecting surface. When these conditions cannot be met, the actual location utilized shall be noted in writing. F. Calibration. Prior to, and after each measurement period, the sound level meter shall be calibrated using an acoustic calibrator of the coupler type. Each year, the sound level meter and acoustic calibrator shall be calibrated to manufacturers' specifications by a laboratory subject to the National Bureau of Standards. G. Ambient Noise. 1. Compliance applies only to the alleged offending source. Preferably, an ambient measurement will be measured at the affected property while the source is nonoperational and immediately prior to or immediately after the measurement period while the source is operating. If this procedure is not feasible and the source operation cannot be controlled, then an ambient measurement will be made at some other location in the vicinity that in the judgment of the measurement technician is representative of the situation at the affected property. 2. If the ambient level is below the source level by 10 dB(A) or more, then the measurement with the source in operation will be equivalent to the source alone within the prescribed resolution. If the ambient level is less than 10 dB(A) lower than the source, then the ambient level will be subtracted logarithmically from the combined measurement to determine the actual source level. If the ambient level is higher than the source level, the source will be considered to comply regardless of its level. H. Record Keeping. When applying this section for an enforcement action, the following information, as a minimum, shall be recorded and maintained: 1. The date, start time, stop time, average "A" weighted sound level, meter scale when appropriate, slow or fast response, equipment manufacturer, model number and serial number, and the ambient sound level shall be documented. 2. The location of the source, the property measurement point, and the ambient measurement point shall be documented and scaled dimensionally. Photos are not necessary but encouraged. The data sheets shall be signed and dated by the measurement technician. 3. In the event auxiliary recording devices are used for data storage, then settings shall be listed, and equipment type, manufacturer, model and serial number listed. I. Verification. If data is to be used for enforcement purposes, the technician will certify in writing that the data recorded was from the source and that all procedures have been complied with in the measurement and reporting.

( Prior code § 5400.950 )

Ask a question about Upland law

Corpus searches the Upland sections it holds and shows the ones that match, with their citations. Free, no sign-in.