Sec. 23-128. - Water test—Required.
Every house connection sewer shall be tested before being approved, in that portion extending from the property line to the upper terminus thereof by a static water pressure test, which shall consist of filling the line or lines with water and carrying the level of the column of such water to a height sufficient to develop a pressure of two (2) pounds per square inch at the lower terminus thereof, and in no event to a height of less than four (4) inches above the top of the upper terminal end of such sewer; or, in lieu of such static water pressure test, by a pump test which shall consist of filling such line or lines with water, capping or sealing each upper terminus thereof, and applying an air pump at the property line in such a manner as to furnish an aggregate pressure of two (2) pounds per square inch in the sewer at the lower terminus.
(Code 1960, § 5251.1)