Sec. 23-39. - Trailer court connections.

(a) The service or utilities building of a trailer court shall be connected to the public sewer by a six (6) inch house connection sewer laid on a grade of not less than one-fourth inch per foot if it serves more than one hundred eighty (180) fixture units, as shown in section 23-37. The laterals through the trailer locations may be constructed with four (4) inch pipe, laid on a grade of not less than one-fourth inch rise, per foot. (b) The upper end of each run shall be provided with a four (4) inch vent stack extended at least ten (10) feet above ground, and distant ten (10) feet from the neighboring property lines. (c) Each separate lateral to a trailer location shall be vented when directly connected to the house connection sewer extending from the service or utilities building to the public sewer. (d) The sewer inlets provided for the hose connections from the trailer sinks, shall be set four (4) inches or more above ground level, and shall be provided at the base with two (2) inch, three (3) inch or four (4) inch cast iron "P" trap. All two (2) inch traps shall be vented. (e) The branches to these inlets may be made with either two (2) inch cast iron soil pipe, laid on one-fourth inch rise per foot, and extending not more than two (2) feet from the vent to the trap, or, three (3) inch cast iron soil pipe, or, four (4) inch vitrified clay pipe or cast iron soil pipe, not to exceed fifteen (15) feet in length, laid on one-fourth inch rise per foot. If laid steeper than one-fourth inch per foot, or longer than above provided, they shall be separately vented. (f) No rain or surface water shall be permitted to enter the sewer through the inlets. (g) Vent stacks shall be constructed of cast iron soil pipe, below the surface of the ground. Standard galvanized, wrought-iron, or steel pipe, may be used above the surface of the ground.

(Code 1960, § 5246; Ord. No. 1487, § 4, 8-25-80)

Ask a question about West Covina law

Corpus searches the West Covina sections it holds and shows the ones that match, with their citations. Free, no sign-in.