Sec. 23-82. - Grease interceptor requirements.
All grease interceptors must comply with all relevant city ordinances, and the current edition of the California Plumbing Code. (a) Grease interceptor sizing and installation shall conform to the current edition of the California Plumbing Code. Grease interceptors shall be constructed in accordance with the design approved by the city's director of public works or his/her designee, city engineer, or the building and safety official or his/her designee and shall have a minimum of two (2) compartments with fittings designed for grease retention and a sampling box. (b) The grease interceptor shall be installed at a location where it shall be at all times easily accessible for inspection, cleaning, and removal of accumulated grease. (c) Access manholes shall be provided over each grease interceptor chamber and tee. The access manholes shall extend at least to finished grade and be designed and maintained to prevent water inflow or infiltration. The manholes shall also have readily removable covers to facilitate inspection, grease removal, and wastewater sampling activities. (d) Grease interceptors shall be maintained in efficient operating condition by periodic removal of the full content of the interceptor which includes wastewater, accumulated FOG, floating materials, sludge and solids. All existing and newly installed grease interceptors shall be maintained in a manner consistent with a maintenance frequency approved by the director of public works or his/her designee pursuant to this section. No FOG that has accumulated in a grease interceptor shall be allowed to pass into any sewer lateral, public sewer, storm drain, or public right of way during maintenance activities. All establishments with grease interceptors may be required to submit data and information necessary to establish the maintenance frequency of the grease interceptors and shall be determined in one (1) of the following methods: (1) Grease interceptors shall be fully pumped-out and cleaned at a frequency such that the combined FOG and solids accumulation does not exceed twenty-five (25) percent of the total liquid depth of the grease interceptor. This is to ensure that the minimum hydraulic retention time and required available volume is maintained to effectively intercept and retain FOG discharged to the public sewer. (2) All food service establishments with a grease interceptor shall maintain their grease interceptor not less than once every four (4) months. The maintenance frequency shall be adjusted when sufficient data have been obtained to establish an average frequency based on the requirements described in above paragraph (d). The director of public works or his/her designee may change the maintenance frequency at any time to reflect changes in actual operating conditions. Based on the actual generation of FOG from an establishment, including food service establishments that generate FOG, the maintenance frequency may increase or decrease. (3) If the grease interceptor, at any time, contains FOG and solids accumulation that does not meet the requirements described in (1), any establishment, including food service establishments generating FOG, shall be required to service its grease interceptor(s) immediately to assure that all fats, oils, grease, sludge, and other materials are completely removed from the grease interceptor. If deemed necessary, the director of public works or his/her designee may also increase the maintenance frequency of the grease interceptor from the current frequency.
(Ord. No. 2236, § 1, 10-2-12)
Ask a question about West Covina law
Corpus searches the West Covina sections it holds and shows the ones that match, with their citations. Free, no sign-in.