§ 15.08.060: Amendments to referenced standards.

Chapter 35 Referenced Standards is adopted in its entirety as amended by the State Fire Marshall with the following amendments: NFPA 13, 2025 Edition, Standard for the Installation of Sprinkler Systems is hereby amended as follows: Section 9.2.1.7 is hereby revised as follows: 9.2.1.7 Concealed spaces filled with noncombustible insulation shall not require sprinkler protection when approved by the fire code official. Section 9.4.3.1 is hereby revised as follows: 9.4.3.1 When fire sprinkler systems are installed in shell buildings of undetermined use (Spec Buildings) other than warehouses (S occupancies), fire sprinklers of the quick-response type shall be used. Use is considered undetermined if a specific tenant/occupant is not identified at the time the fire sprinkler plan is submitted. Sprinklers in light hazard occupancies shall be one of the following: (1) | Quick-response type as defined in 3.3.223.4.16 (2) | Residential sprinklers in accordance with the requirements of Chapter 12 (3) | Quick-response CMSA sprinklers (4) | ESFR sprinklers (5) | Standard-response sprinklers used for modifications or additions to existing light hazard systems equipped with standard-response sprinklers. (6) | Standard-response sprinklers used where individual standard-response sprinklers are replaced in existing light hazard systems. Section 16.12.3.3 is hereby revised as follows: 16.12.3.3 Fire department connections (FDC) shall be of an approved type. The location shall be approved and be no more than 150 feet from a public hydrant. The FDC may be located within 150 feet of a private fire hydrant when approved by the fire code official. The size of piping and the number of 2 1/2" inlets shall be approved by the fire code official. If acceptable to the water authority, it may be installed on the backflow assembly. Fire department inlet connections shall be painted OSHA safety red or as approved. When the fire sprinkler density design requires more than 500 gpm (including inside hose stream demand), or a standpipe system is included, four 2 1/2" inlets shall be provided. NFPA 13D 2025 Edition, Standard for the Installation of Sprinkler Systems in One-and Two-Family Dwellings and Manufactured Homes is hereby amended as follows: Section 7.1.2 is hereby revised as follows: 7.1.2 The sprinkler system piping shall not have separate control valves installed unless supervised by a central station, proprietary, or remote station alarm service. NFPA 24, 2025 Edition, Standard for the Installation of Private Fire Service Mains and Their Appurtenances is hereby amended as follows: Section 6.2.8.1 is hereby added as follows: 6.2.8.1 All indicating valves controlling fire suppression water supplies shall be painted OSHA red. Exceptions: 1. | Brass or bronze valves on sprinkler risers mounted to the exterior of the building may be left unpainted. 2. | Where OS&Y valves on the detector check assembly are the only control valves, at least one OS&Y valve shall be painted red. Section 6.2.9 is hereby revised as follows: All connections to private fire service mains for fire protection systems shall be arranged in accordance with one of the following so that they can be isolated: (1) | A post indicator valve installed not less than 40 ft (12 m) from the building a. | For buildings less than 40 ft (12 m) in height, a post indicator valve shall be permitted to be installed closer than 40 ft (12 m) but at least as far from the building as the height of the wall facing the post indicator valve. b. | Post indicating valves shall be allowed to be closer than 40 ft (12 m) to the building when a property line or other physical barriers make it impossible to have a post indicating valve 40 ft (12 m) away. c. | Post indicating valves shall be allowed to be closer than 40 ft (12 m) to the building when building driveway or fire access roadways or other building traffic make it impractical to be 40 ft (12 m). (2) | A wall post indicator valve on risers located within the building, either a nonrising stem gate valve with a wall post indicator or a listed butterfly valve with an indicating handle extending out through the building wall. (3) | A backflow preventer with at least one indicating valve not less than 40 ft (12 m) from the building. (a) | For buildings less than 40 ft (12 m) in height, a backflow preventer with at least one indicating valve shall be permitted to be installed closer than 40 ft (12 m) but at least as far from the building as the height of the wall facing the backflow preventer. (b) | Backflow preventer valves shall be allowed to be closer than 40 ft (12 m) to the building when a property line or other physical barriers make it impossible to have a backflow preventer valve 40 ft (12 m) away. (c) | Backflow preventer valves shall be allowed to be closer than 40 ft (12 m) to the building when building driveway or fire access roadways or other building traffic make it impractical to be 40 ft (12 m). (4) | Indicating control valves installed in a fire-rated room accessible from the exterior. (5) | Indicating control valves in a fire-rated stair enclosure accessible from the exterior as permitted by the AHJ. (6) | Any other valve type or location as permitted by the AHJ. Section 10.1.5 is hereby added as follows: 10.1.5 All ferrous pipe and joints shall be polyethylene encased per AWWA C150, Method A, B, or C. All fittings shall be protected with a loose 8-mil polyethylene tube or sheet. The ends of the tube or sheet shall extend past the joint by a minimum of 12 inches and be sealed with 2-inch-wide tape approved for underground use. Galvanizing does not meet the requirements of this section. Exception: 304 or 316 Stainless Steel pipe and fittings Section 10.4.1.1 is hereby revised as follows: 10.4.1.1 All bolted joint accessories shall be cleaned and thoroughly coated with asphalt, bituminous, or other corrosion-retarding material after installation. Exception: Bolted joint accessories made from 304 or 316 stainless steel. Section 10.4.1.1.1 is hereby added as follows: 10.4.1.1.1 All bolts used in pipe-joint assembly shall be 316 stainless steel. Section 10.4.3.2 is hereby deleted and replaced as follows: 10.4.3.2 Where fire service mains enter the building adjacent to the foundation, the pipe may run under a building to a maximum of 24 inches, as measured from the interior face of the exterior wall to the center of the vertical pipe. The pipe under the building or building foundation shall be 304 or 316 stainless steel and shall not contain mechanical joints or it shall comply with 10.4.3.2.1 through 10.4.3.2.4. Appendix J is hereby amended as follows: Sections J103.1 and J103.2 are hereby deleted and replaced as follows: J103.1 Permits and Exceptions. 1. | Grading permits. No person shall conduct any grading, clearing, brushing, or grubbing on natural or existing grade that is preparatory to grading, without first having obtained a grading permit. Exception to this requirement are as follows or as otherwise determined by the City Engineer: a. | An excavation below finished grade for basement and footing of a building, mobile home, retaining wall, or other structure authorized by a valid building permit or construction permit. This shall not exempt any fill made with the material from such excavation nor exempt any excavation have an unsupported height greater than five (5) feet after the completion of such structure. This shall not prohibit a minimum fee grading permit or soil or geologic report from being required for foundation design and inspection purposes when, in the opinion of the City Engineer, soil stability or flooding considerations warrant such inspection. b. | Cemetery graves. c. | Refuse disposal sites controlled by other regulations. d. | Earthwork construction regulated by the Federal, State, County, or City Governments, or by any local agency as defined by Government Code Sections 53090 through 53095 (special districts), pipeline or conduit excavation and backfill conducted by local agencies or public utilities, earthwork construction performed by railway companies or their operating property, dedicated rights-of-way, or easements of the above agencies. e. | Excavation and backfill for installation of underground utilities by public utilities or companies operating under the authority of a franchise or public property encroachment permit. f. | Mining, quarrying, excavating, processing, stockpiling of rock, sand, aggregate, or clay where established and provided for by law, under other agency permit(s), provided such operation does not affect the lateral support or increase the stresses in or pressures upon any adjacent or contiguous property. g. | Exploratory excavations under the direction of soil engineers or engineering geologists, provided all excavations are properly backfilled as required by the City Engineer. All such excavations and trenches are subject to the applicable section of Title 8 of the State Orders, Division of Industrial Safety. h. | An excavation which does not exceed twenty-five (25) cubic yards on any one site and which is less than one (1) foot in vertical depth. i. | A fill less than one foot in depth placed on natural grade with a slope flatter than five horizontal to one vertical (5:1), which does not exceed twenty-five (25) cubic yards on any one site and does not obstruct a drainage course. j. | A fill less than three (3) feet in depth, not intended to support structures or mobile homes which does not exceed twenty-five (25) cubic yards on any one site and does not obstruct a drainage course. 2. | Grading permit, paving. No person shall construct pavement surfacing in excess of three thousand (3,000) square feet, on natural or existing grade without a valid grading permit unless waived by the City Engineer, or unless a separate improvement plan for such paving is approved by the City Engineer. Resurfacing or maintenance of paved surface shall be exempt from this requirement. 3. | Grading permit, construction. No person shall construct without a valid grading permit any new building/substantial remodel, or building addition that increases the existing footprint by 1,000 SF or more, for which a building permit from the City is required, unless waived by the City Engineer. Exception to this requirement are as follows: a. | Room addition and/or Accessory Dwelling Unit being added to one single-family dwelling in a residential zoning district where the one single-family dwelling unit in the ONLY dwelling unit of the land parcel.

( Ord. 2629 , 11/12/2025 )

Ask a question about Westminster law

Corpus searches the Westminster sections it holds and shows the ones that match, with their citations. Free, no sign-in.