For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.300.030 — Fences, Hedges, and Walls

Code of Ordinances, City of Westminster, California (eCode360 WE5033 publication; scraped 2026-11-22) · Westminster Code of Ordinances § 17.300.030

Corpus is an independent public-information project, not the official City of Westminster website. Stable reference: corpuslaw.us/code/b0e5720a-2b3a-47b9-a8e4-fb824b248283

§ 17.300.030: Fences, Hedges, and Walls.

A. Applicability. Fences, walls used as fences, latticework screens, hedges, thick growths of shrubs or trees, open-mesh wire fences, and walls shall be installed and maintained in compliance with the provisions outlined in this Section. These regulations do not apply to fences required by the City for reasons of public safety. B. General Height Limitations. Fences, hedges, and walls shall comply with the height limitations outlined in Table 3-2. See Figure 3-3, Measurement and Location of Fence or Wall Height, for illustration of height limitations. Table 3-2Maximum Height of Fences, Hedges and Walls Location | Maximum Height | Additional Requirements Specific Zone R1 zoning district, side and rear yard | 6 feet | When an R1-zoned property abuts a freeway right-of-way, fence, hedge, and wall height shall be no less than 8 feet All zoning districts other than R1, side and rear yard | 8 feet | When the fence does not abut property in an R1 zoning district All Zones Front YardWithin the required front setback of any lot or the required rear yard of any through lot | 3 feet | For properties located in the R2, R3, R4, and R5 zoning districts and that are developed with multiple-family units, refer to Section 17.300.030.EWithin the front yard setback of any flag lot, the maximum permitted height of a fence, block wall, or hedge shall be 6 feet. Within the 20-foot front yard of the 'flag pole' on any flag lot, the maximum permitted height of a fence, block wall, or hedge shall be 3 feet. Corner-Lot ExceptionAny point within 25 feet of the point of intersection or center of the corner cutoff of two streets or a street and an alley | 3 feet | In the case of a corner lot that abuts an alley, not more than 3 feet in height at any point within 10 feet of said point of intersection Any point within 10 feet of the point of intersection of a corner lot that abuts an alley | 3 feet | Not applicable That portion of the rear yard of a corner lot that abuts the front yard of any adjacent lot for a distance not to exceed 10, and for an equal distance not to exceed 10 along the exterior side lot line of said corner lot, in order to create a triangular area in which sight distance would not be impaired above 3 feet in height | 3 feet | Not applicable [image] Figure 3-3 Measurement and Location of Fence or Wall Height C. Measurement of Height. The height of a wall or fence along an interior property line shall be measured from the higher natural or established grade of the two abutting properties. If the wall is within five feet of the public right-of-way, the height of the wall shall be measured from the grade of the abutting right-of-way. D. Materials and Design. Fences and walls should be built with attractive, durable materials, including, but not limited to, redwood, wrought iron, textured concrete block, or formed concrete with reveals. Chainlink fencing, corrugated metal fencing, and/or fiberglass fencing, and "tennis windscreens" are not permitted within the front yard or street side yard areas. E. Multiple-Family Residential. A 6-foot high fence may be permitted within the front yard 20-foot setback for multiple-family units in the R2 to R5 zoning districts, subject to the provisions of Article 5 and provided that no other variances to the WMC are proposed. Such fences shall maintain the following standards in addition to subsection (D – Materials and Design): 1. Fencing material may extend above 3 feet in height but not exceeding 6 feet in height, as measured from the highest finished grade abutting the fence, provided such vertical extension does not impair visibility through the obscuring of more than 10 percent of the area in the vertical plane. This is equivalent to 1-inch wide balusters placed approximately 9 inches on center. Masonry pilasters used above the 3-foot level shall be no more than one-foot wide. Variations in design are subject to site plan approval, and shall be evaluated on a case-by-case basis. 2. All proposed fencing materials shall be decorative in nature. Fences shall not consist solely of vertical wrought-iron balusters. 3. Fences shall be behind 5-foot wide perimeter landscaping area, provided that existing site features do not prohibit such a setback. Variations in landscaping-area design are preferable, with intermittent placement and/or varied widths, in a consistent design, being encouraged. Variations due to existing site-design constraints shall be evaluated on a case-by-case basis. 4. Vehicle entrance gates shall be set back a minimum of 20 feet from the property line in order to provide for a vehicle holding area. All gates/fences shall be provided with lock boxes, subject to fire department and police department approval. F. Special Wall and Fencing Requirements 1. Screening of outdoor equipment, storage, and work areas shall be provided in accordance with Section 17.300.035, Screening. 2. Temporary fencing may be approved as deemed necessary and appropriate by the Director. 3. Whenever an off-street parking area is adjacent to or across an alley from property being used for residential purposes, a solid masonry wall 6 feet in height shall be erected and maintained along the property line so as to physically separate the parking area from the residential property. Such wall shall be 3 feet in height when within the required front or street side-yard setback. Where no front or street side-yard setback is required, such wall shall be 3 feet in height when within 10 feet of the street right-of-way. 4. Whenever an off-street parking area is across a street from property being used for residential purposes, a masonry wall not less than 3 feet in height shall be erected and maintained along the street side of the lot and no closer to the street than the required depth of the yard in the adjoining residential area. 5. All property used for cemetery purposes shall be enclosed by a fence, wall, or structure used as a wall, not less than 8 feet in height; however, that any such fence, wall, or structure installed within 50 feet of an intersection shall be wire mesh or similar material so as not to obstruct traffic visibility. 6. Where any property used for industrial purposes has a common property line with property zoned for residential purposes, a solid masonry or concrete block wall shall be provided not less than 8 feet in height on such property line, except where the face of a building is on such property. 7. Where any property in the M1 zoning district is used for supply or storage yards, or other uses that are permitted to be conducted outside of a building (e.g., stock and public scales), that portion of the property that is so used shall be enclosed with a wall or chain-link fence not less than six feet in height, in order to discourage trespassing, provided that where the face of a building is on any site boundary, no separate wall or fence is required to be installed along the boundary line occupied by the face of the building. G. Security Fencing. Fences in all zoning districts shall not incorporate electrical currents, concertina ribbon, razor wire, razor ribbon, and/or pointed, protruding, or sharp objects or elements, or similar type of restraining device except as provided in Section 17.300.035.H. (Exception: Wrought-iron fences may incorporate decorative arrowhead and curved point tips.) H. Barbed-Wire Fencing 1. Where outside activities are conducted in the C1 and C2 zoning districts, including new and used vehicle sales, mobile home sales, recreation vehicle storage facilities, and electrical distribution stations, or in the CM, M1, and M2 zoning districts where storage of hazardous materials is permitted, or in high risk areas such as electrical or pump stations, a maximum of four strands of strong barbed wire may be permitted under the following conditions: a. The barbed wire is placed on top of a wall or fence at least 6 feet in height; b. The barbed wire strands do not raise the total height of the wall or fence above 8 feet; c. The barbed wire is not adjacent to public walkways in the CR and C1 zoning districts; and d. The barbed wire does not encroach over public right-of-way at any location. 2. Barbed wire is prohibited on or between properties and adjacent to public walkways in the R1 to R5 zoning districts.

( Ord. 2456 § 2, 2010 ; Ord. 2478 § 2, 2011 ; Ord. 2580U § 6, 2022 )

Ask a question about Westminster law

Corpus searches the Westminster sections it holds and shows the ones that match, with their citations. Free, no sign-in.