For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.330.085 — Standards for Specific Sign Types

Code of Ordinances, City of Westminster, California (eCode360 WE5033 publication; scraped 2026-11-22) · Westminster Code of Ordinances § 17.330.085

Corpus is an independent public-information project, not the official City of Westminster website. Stable reference: corpuslaw.us/code/80b9c30d-6bf4-4749-8b4e-e73b6a2184ff

§ 17.330.085: Standards for Specific Sign Types.

A. Required Standards. Tables 3-10 to 3-12 outline the required standards by specific sign types and characteristics. Table 3-10Number, Dimensions, and Location of Freestanding Signs by Zoning District Sign Type | R11 | RM | IN2 | PF | C | I | LS | CC | V Monument Area (square feet/face) | NA | 50 | 100 | 100 | 100 | 100 | 100 | 100 | NA Height (feet) | NA | 6 | 6 | 6 | 6 | 6 | 6 | 83 | NA Setback (feet)4 | NA | 10 | 10 | 10 | 10 | 10 | 10 | 10 | NA Number permitted per lot | NA | 1 | 15 | NA | NA | NA | NA | NA | NA Number permitted per feet of street frontage | NA | NA | NA5 | NA5 | 1 per 3006 | 1 per 3006 | 1 per 3006 | 1 per 5003 | NA Pylon or pole sign7,8 Area (square feet/face) | NA | NA | 100 | 100 | 100 | 100 | 100 | 200 | NA Height (feet) | NA | NA | 25 | 25 | 25 | 25 | 25 | 253 | NA Setback (feet)3,4 | NA | 10 | 10 | 10 | 10 | 10 | 10 | 10 | NA Number permitted per lot | NA | NA | 15 | 15 | NA | NA | NA | NA | NA Number permitted per feet of street frontage | NA | NA | NA5 | NA5 | 1 per 3006 | 1 per 3006 | 1 per 3006 | 1 per 20003 | NA Notes: NA = Not Applicable 1 | Refer to Tables 3-8 and 3-9 for permitted free-standing sign allowances in the R1 zoning district. 2 | This class of uses applies to institutional and quasi-institutional uses allowed under this Title within any zoning district, subject to a Conditional Use Permit. Such uses may include but are not limited to day-care facilities, convalescent hospitals, senior housing, and similar uses. 3 | In the Civic Center Overlay, one pylon sign is permitted if the lot has at least 2,001 lineal feet of street frontage. The number of monument signs and their height are determined as follows: Lineal Street Frontage | No. of Signs Permitted | Maximum height 0-100 | none | NA 101-500 | 1 | 6 501-1,000 | 2 | 6 1,001-1,500 | 3 | 6 1,501-2,000 | 4 | 6 2,000 or more | 4 monument | 6 1 pylon | 25 4 | Setbacks for monument and pylon signs may be reduced to 3 feet if the City Engineer determines that such signs will not obstruct street visibility. No part of a pylon sign shall project into the public right-of-way. 5 | On lots in residential zones that are developed with institutional/quasi-institutional uses or public-facility uses, one freestanding sign is permitted regardless of lineal street frontage, except that compliance with the provisions outlined in Table 3-9 is required for these uses. For these uses in a commercial or industrial zone, or within the Civic Center or Little Saigon Overlays, freestanding signs are permitted only in conformance with notes 3 and 6. 6 | In commercial and industrial zones, and in the Little Saigon Overlay, the following limitations apply to monument and pylon signs: Lineal Street Frontage | No. of Signs Permitted 0-100 | none 101-300 | 1 301-750 | 2 751-1,500 | 3 1,501-2,000 | 4 Over 2,000 | 5 7 | Any billboard or permissible structural or electrical modification thereof permitted by this Chapter shall be subject to the regulations of this Chapter and Section 17.300.090. 8 | The design of a pole sign is subject to Section 17.330.085(B)(4)(e). Table 3-11Number and Dimensions for Specific Sign Types1 Sign Type | Number Allowed | Maximum Area | Minimum Vertical Clearance Freestanding Monument | See Table 3-10 | See Table 3-10 | NA Pylon or pole sign | See Table 3-10 | See Table 3-10 | 8 feet Billboard2 | 1 per lot | See § 17.330.090 | See § 17.330.090 Identification3 | 1 per building | 50 square feet | 8 feet Incidental | Per master sign plan | Per master sign plan | Per master sign plan Building Arcade | 1 per main entrance | Per master sign plan/Table 3-9 | 9 feet Building marker | 1 per building | 4 square feet | NA Canopy | 1 per principle use or building | 25% of vertical surface of canopy/Table 3-9 | 9 feet Identification3 | 1 per building | 50 sq. ft. | NA Incidental | Per master sign plan | Per master sign plan | Per master sign plan Marquee | 1 per principle use or building | See Table 3-9 | 9 feet Projecting4 | 1 per principle use or building | See Table 3-9 | 9 feet Roof, integral | 1 per principle use or building | See Table 3-9 | NA Suspended | 1 per principle use or building | See Table 3-9 | 9 feet Wall5 | 1 per principle use or building | 1.5 sq. ft. for every linear foot of building frontage or tenant space frontage | NA Window6, 7, 8 | 1 per storefront window | 25% of window/Table 3-9 | NA Miscellaneous Banner6, 9, 10 | 1 per principle use | 40 sq. ft./sign | 9 feet Flag9, 11, 12, 13 | Per master sign plan | 216 sq. ft. | 9 feet Pennant6, 9 | Per special event or temporary sign permit | NA | 9 feet Temporary4 | Per special event or temporary sign permit | NA | 4 feet Special advertising device14 | Per § 17.330.055 | Per § 17.330.055 | Per § 17.330.055 Inflatable device15 | Per § 17.330.050 or 17.330.055 | Per § 15.40.110 or 17.330.055 | 30 feet Notes: NA = Not Applicable; CUP = Conditional Use Permit 1 | No signs shall exceed any applicable maximum numbers or dimensions, or encroach on any applicable minimum clearance shown in this table. 2 | Any billboard or permissible structural or electrical modification thereof permitted by this Chapter shall be subject to the regulations of this Chapter and Section 17.330.090, including the requirement for a Conditional Use Permit. 3 | Identification signs shall not be allowed in addition to any other permitted freestanding or building sign, nor shall they exceed any other limitations imposed on pylon signs. 4 | Projecting signs may project up to 2 feet into the public right-of-way only in the Civic Center Overlay, pursuant to footnote 5 of Table 3-8 and provided that the building is set back from the front property line no more than 5 feet. 5 | One additional wall sign may be permitted for a principal use or building that faces 2 streets, provided that such second wall sign does not exceed 50% of the area of the first wall sign and is attached so as to face the second street frontage. 6 | Temporary signs, including temporary window signs, pennants, and all other types of temporary signs, except for balloon and other inflatable or aerial signs, shall be subject to the provisions of Section 17.330.025. 7 | A maximum of 1 neon-type window sign is allowed per business included within the 25% total allowable window sign area, except that neon tubing used solely to outline a window, or any portion of a window, no more than 12 inches from the edge of any window pane, shall be exempt from the calculation of the maximum sign-area requirements. 8 | For purposes of computation of the allowable sign area, a window shall consist of the total glass area constituting a storefront window, but not including glass doors or opaque windows. 9 | For apartment complexes consisting of 16 or more units, the provisions of Section 17.330.050 shall apply. 10 | For grand openings, as permitted in Section 17.54.050. The maximum area of a banner may exceed 40 square feet; however, in no case shall it exceed an area equal to 15% of the face of the building to which it is affixed. 11 | In all residential zones, a flag shall not exceed 108 square feet (9 feet by 12 feet) in area and the pole shall not exceed 35 feet in height. 12 | For multitenant buildings, no more than one flag, such as a seasonal flag or corporate flag, per storefront shall be permitted. 13 | A building permit shall be required for the construction of a flagpole. 14 | Special advertising devices shall be subject to the provisions of Section 17.330.055. 15 | Inflatable devices are permitted for all automobile dealerships pursuant to Section 17.330.050. For all other commercial uses, inflatable devices are permitted only under the terms of Section 17.330.055. 16 | The design of a pole sign is subject to Section 17.330.085B.4.e. Table 3-12Permitted Sign Characteristics by Zoning District Sign Type | R1 | RM | IN1 | PF | C | I | LS | CC | V Animated | NP | NP | NP | NP | NP | NP | NP | NP | NP Changeable copy | NP | NP | P | P | P | P | P | P | NP Electronic message board5 | NP | NP | AUP | AUP | CUP | NP | CUP | AUP | NP Illumination, internal2 | NP | NP | P | P | P | P | P | P | NP Illumination, external3 | NP | P | P | P | P | P | P | P | NP Illumination, exposed bulb or neon | NP | NP | NP | NP | NP | NP | NP | NP | NP Inflatable4 | NP | NP | NP | NP | P | NP | NP | P | NP Notes: P = Permitted; NP = Not Permitted 1 | This class of uses applies to institutional and quasi-institutional uses allowed under this Title within any zoning district, subject to a Conditional Use Permit. Such uses may include, but are not limited to, day care facilities, convalescent hospitals, senior housing, and similar uses. 2 | Backlit panels are prohibited. Panels shall be opaque if can-type signs are used and only the lettering shall appear to be illuminated. Backlit individually-cut letter signs are permitted. All electrical raceways shall be concealed, except that the Director may waive the requirement for concealed raceways if it can be found that such concealment is impractical due to the design of the building. 3 | Direct and indirect lighting methods are allowed except that they shall not be harsh or unnecessarily bright. Reflectors shall be used to keep light from spilling beyond the limits of the sign face if direct lighting methods are used. 4 | Inflatable devices are permitted for all automobile dealerships pursuant to Section 17.330.050. For all other commercial uses, inflatable devices are permitted only under the terms of Section 17.330.055. 5 | Electronic message boards shall be limited to a maximum of one sign per site. Such signs shall only be permitted on sites with 100,000 square feet or more of gross floor area, except for institutional and public facility land uses, which are exempt from this minimum area requirement. Additionally, the electronic message board must be located at least 250 feet away from residential uses, as measured from the closest edge of the sign face to the exterior wall of the nearest habitable residential structure. B. Sign Design Standards. 1. Overview. Signs are an important part of any commercial district, as they help customers identify the stores they are looking for. However, the purpose of signs shall not be to advertise. When too many large signs appear along a street, they compete for attention with one another, and their effectiveness as business identifiers is greatly reduced. The following sign design standards shall be considered in addition to all other applicable requirements of this Title and Chapter 15.36, Uniform Sign Code, of the WMC. 2. General design requirements. The following general design requirements shall be consulted prior to developing signs for any project. a. Consider the proportion of letter area. Letters on signs shall not occupy more than 75 percent of the sign panel area. b. Address identification. Signs, especially free-standing signs, shall include the address of the business or commercial center, whenever appropriate or desirable. c. Neon lighting. Neon lighting may be used as an architectural accent. 3. Building, wall or fascia signs. a. Can-type signs. The use of can-type signs with translucent backlit panels are prohibited. Panels shall be opaque if a can-type sign is used and only the lettering shall appear to be illuminated. In cases where the sign area of the sign is no greater than 40 square feet, translucent backlit panels shall also be permitted. b. Exposed raceways. Exposed raceways behind individual letter signs are prohibited as they emphasize the mechanics of the sign rather than the message. Buildings shall be designed to conceal electrical raceways. For existing buildings, exposed raceways may be permitted with the approval of the Planning Division when concealed electrical raceways are not possible, provided that the raceway is designed to blend with the building/structural wall to which it is attached. c. Remove brackets and repair holes. When existing signs are removed or replaced, all brackets, poles, and other supports that are no longer required shall be removed. Any holes that remain shall be patched and painted to match the surrounding portion of the building or sign support structure. 4. Freestanding signs. a. Sign types. Freestanding signs, including monument, pole and pylon signs, are permitted pursuant to the following provisions and those outlined in Table 3-8. b. Number, location, area, height, and design. The number, location, and area of a monument, pole or pylon sign shall be in compliance with the provisions outlined in Tables 3-9 to 3-11. c. Monument signs. Monument signs shall be placed within a landscaped area that is at least equal to two times the square footage of the sign face. All tenant sign panels on monument signs shall be no larger than the width of the architectural features of the sign and should be uniform in size and color. Simple, uncomplicated shapes should be used. d. Pylon signs. Pylon signs shall be designed to be supported by two columns; bare poles are not permitted. The design of a pylon sign, including the supporting columns, shall be compatible and consistent with the design of the commercial development. All tenant sign panels on pylon signs shall be limited in size to the width of the twin columns or architectural features of the sign and should be uniform in size and color. Simple, uncomplicated shapes should be used. e. Pole signs. Monument signs are preferred; however, single pole signs are permitted provided that the pole is covered with a decorative skirt compatible with the design of the sign and with a width equal to at least half the width of the sign. 5. Window signs. a. Number of signs. If permanent window signs are used, they shall be limited to one per window. b. Sign area. The area of any permanent window sign shall be in accordance with the provisions outlined in Table 3-11. c. Illuminated signs. Internally illuminated cabinet or "can" signs and changeable-copy signs should be placed at least three feet behind the window surface. d. Placement. Limited to upper half of a window. e. Location. Limited only to the ground floor for multi-story buildings. 6. Arcade signs. a. Size. Arcade signs shall not exceed 12 inches by 30 inches in size. b. Location. Arcade signs perpendicular and/or parallel to the building face may be installed in multitenant centers underneath arcade roofs. A minimum vertical clearance of 8 feet shall be provided between the walkway and the bottom of the sign. [image] 7. Banners. a. Location. Banners shall be located on the building storefront wall above the business they identify and shall not be located on the roof of a building or on the railings. b. Sign copy. Banners shall only advertise and identify the on-site business for which the permit is issued.

( Ord. 2456 § 2, 2010 ; Ord. 2548 §§ 3, 4, 2018 ; Ord. 2618 , 4/9/2025 ; Ord. 2633 , 3/11/2026 )

Ask a question about Westminster law

Corpus searches the Westminster sections it holds and shows the ones that match, with their citations. Free, no sign-in.