§ 106-2 — Definitions
Code of Ordinances of the City of Arvada, Colorado (Supp. No. 67: codified through Ordinance No. 4932, enacted May 5, 2026) · Arvada Code of Ordinances § 106-2
Corpus is an independent public-information project, not the official City of Arvada website. Stable reference: corpuslaw.us/code/d84640f1-cac9-4fac-80c2-83b7d1e26368
Sec. 106-2. - Definitions.
The following words, terms, and phrases, when used in this chapter, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning: Accessory structure means a subordinate building, or portion of a main building, the use of which is incidental to that of the main building on the same lot. This includes detached garages, workshop, sheds, barns, coops, greenhouses, and detached living space. Approved means acceptable to the code official. Barn means a building used exclusively for the housing and care of horses or other permitted livestock, and for the storage of feed, hay, other farm crops, and farm or equine equipment. Barns may not be used for a garage or as a storage shed for items not associated with livestock or farm crops. Building means any structure intended for supporting or sheltering any occupancy. Class A Tests means tests applicable to roof coverings that are expected to be effective against severe fire exposure, before a high degree of fire protection to the roof deck, do not slip from position, and are not expected to present a flying brand hazard. Code Official means the official designated by the jurisdiction to interpret and enforce this code, or the code official's authorized representative. Defensible space means an area either natural or man-made, where material capable of allowing a fire to spread unchecked has been treated, cleared or modified to slow the rate and intensity of an advancing wildfire and to create an area for fire suppression operations to occur. Embellishments means elements incorporated in design and construction for ornamental or decorative purposes that are not integral to the structure or structural support. Fire intensity classification meansthe level of fire intensity identified for areas where significant fuel hazards and associated dangerous fire behavior may exist, based upon vegetative fuels, topography, weather conditions, and flame length value. Fire-resistance-rated construction means the use of materials and systems in the design and construction of a building or structure to safeguard against the spread of fire within a building or structure and the spread of fire to or frombuildings or structures to the wildland-urban interface area. Fire-retardant-treated wood means any wood product that, when impregnated with chemicals by a pressure process or other means during manufacture, shall have, when tested in accordance with ASTM E84 or UL 723, a listed flame spread index of 25 or less. The ASTM E84 or UL 723 test shall be continued for an additional 20 minute. And the flame front shall not progress more than 10.5 feet beyond the center line of the burners at any time during the test. Flame spread index means comparative measure, expressed as the dimensionless number, derived from visual measurements of the spread of flame versus time for a material tested in accordance with ASTM 84. Fuel modification means a method of modifying fuel load by reducing the amount of non fire resistive vegetation or altering the type of vegetation to reduce the fuel load. Habitable space means a space in a building for living, sleeping, eating or cooking. Historic structure means any building or structure that has one or more of the following: (1) Listed, or certified as eligible for listing, by the state historic preservation office or keeper of the National Register of Historic Places, in the National Register of Historic Places. (2) Designated as historic under applicable state or local law. (3) Certified as contributing resource within the National Register, state designated or locally designated historic district. Home ignition zone (Hiz) means the home and the area around the home which takes into account both the potential of the structure to ignite and the quality of defensible space surrounding it. Ignition-resistant building material means a type of building material that resists ignition or sustained flaming combustion sufficiently so as to reduce losses from wildfire exposure of burning embers and small flames. Ignition-resistant building materials shall comply with any of the following: (1) Material shall be tested on all sides with the extended ASTM E84 (UL 723) test or ASTM E2768, except panel products shall be permitted to test only the front and back faces. Panel products shall be tested with a ripped or cut longitudinal gap of ⅛ inch. Materials that, when tested in accordance with the test procedures set forth in ASTM E84 or UL 723 for a test period of 30 minutes, or with ASTM E2768, comply with the following: a. Flame spread. Material shall exhibit a flame spread index not exceeding 25 and shall not show evidence of progressive combustion following the extended 30-minute test. b. Flame front. Material shall exhibit a flame front that does not progress more than 10.5 feet beyond the centerline of the burner at any time during the extended 30-minute test. c. Weathering. Ignition-resistant building materials shall maintain their performance in accordance with this section under conditions of use. Materials shall meet the performance requirements for weathering (including exposure to temperature, moisture and ultraviolet radiation) contained in the following standards, as applicable to the materials and the conditions or use: i. Method A "Test method for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing" in ASTM D2898, for fire-retardant treated wood, wood-plastic composite and plastic lumber materials. ii. ASTM D7032 for wood-plastic composite materials. iii. ASTM D6662 for plastic lumber materials. d. Identification. Materials shall bear identification showing the fire test results. Exception: Materials composed of a combustible core and a noncombustible exterior covering made from either aluminum at a minimum 0.019 inch (0.48 mm) thickness or corrosion-resistant steel at a minimum 0.0149 inch (0.38 mm) thickness shall not be required to be tested with a ripped or cut longitudinal gap. Ignition-resistant vegetation means plants that are less likely to readily ignite from a flame or other ignition source and produce fewer embers. While they can still be damaged by fire, their foliage and stems don't significantly contribute to the intensity of the fire. Log wall construction means a type of construction in which exterior walls are constructed of solid wood members and where the smallest horizontal dimension of each solid wood member is not less than 6 inches. Log wall construction shall follow requirements of ICC 400. Mass timber construction means as described in section 602.4 of the 2024 International Building Code. Also known as Type IV construction. Multilayered glazed panels means window or door assemblies that consists of two or more independently glazed panels installed parallel to each other, having a sealed air gap in between, within a frame designed to fill completely the window or door opening in which the assembly is intended to be installed. Noncombustible, as applied to building construction material, means and material that, in the form in which it is used, is one of the following: (1) Material of which no part will ignite and burn when subjected to fire. (2) Any material confirming to ASTM E136 shall be considered noncombustible within the meaning of this section. (3) For the purposes of this code, fire-rated gypsum board tested in accordance with ASTM C1396 with no less than a 1-hour fire-resistance-rating with fire exposure from the outside only is considered a noncombustible material. Occupiable space means a room or enclosed space designed for human occupancy in which individuals congregate for amusement, education or similar purposes or in which occupants are engaged at labor. Roof assembly means a system designed to provide weather protection and resistance to design loads. The system consists of a roof covering and roof deck or a single component serving as both the roof covering androof deck. A roof assembly can include an underlayment, thermal barrier, ignition barrier, insulation or vapor retarder. Roof covering means the covering applied to the roof deck for weather resistance, fire classification or appearance. Roof deck means the flat or sloped surface not including its supporting members or vertical supports. Slope means the variation of terrain from the horizontal; The number of feet rise or fall per 100 feet measured horizontally, expressed as a percentage. Structure means that which is built or constructed. For the purposes of this code, fences are not considered a structure. Structure ignition zone is the structure and the area around the structure (or home). The SIZ takes into account both the potential of the structure to ignite and the quality of defensible space surrounding it. Tree crown means the primary and secondary branches growing out from the main stem, together with twigs and foliage. Wildfire interface specialist means an individual who meets the minimum training and experience requirements as required by the code official for conducting structure ignition zone inspections. Wildland-urban interface interior means that geographical area farther away from wildland vegetation than the Interface Perimeter where homes are primarily exposed to radiant heat and embers from adjacent homes as well as embers from burning vegetation. These areas have the potential for urban conflagrations. Wildland-urban interface perimeter means that geographical area adjacent to wildland vegetation where homes can be exposed to embers and radiant and convective heat from burning vegetation and adjacent homes. These areas have the potential for wildland fires to transition into urban conflagrations. Wildland-urban intermix means that geographical area where the built environment intermingles with wildland vegetation and where homes are primarily exposed to embers and radiant and convective heat from burning vegetation.
(Ord. No. 4923, § 1, 3-24-2026)
Ask a question about Arvada law
Corpus searches the Arvada sections it holds and shows the ones that match, with their citations. Free, no sign-in.
