§ 106-51 — Class 1 interface structure hardening

Code of Ordinances of the City of Arvada, Colorado (Supp. No. 67: codified through Ordinance No. 4932, enacted May 5, 2026) · Arvada Code of Ordinances § 106-51

Corpus is an independent public-information project, not the official City of Arvada website. Stable reference: corpuslaw.us/code/ca13e40a-7c96-4397-b2bf-386760744695

Sec. 106-51. - Class 1 interface structure hardening.

(a) General. Class 1 structure hardening shall be in accordance with subsections 106-51(b) through (j) and shall apply to buildings and structures hereafter constructed, modified or relocated into or within areas of the wildland-urban interface Class 1. (b) Roofing. Roof shall have a roof assembly classified as Class A when tested in accordance with ASTM E108 or UL790. (1) Flame and ember protection of roofs. For roof assemblies where the roof covering profile creates a space between the roof covering and roof deck, the space shall resist the entry of flames and embers by one or more of the following methods: (i) Fire stopping, with noncombustible material, of the space between the roof covering and the roof deck. (ii) Installation of one layer of cap sheet complying with ASTM D3909 over the combustible roof deck. (iii) Installation of a listed Class A classified roof assembly. (2) Open valley flashings. Open valley flashing shall not be less than 0.019 inch (No. 26 galvanized sheet gauge) corrosion resistant metal installed over a minimum 36-inch-wide underlayment consisting of one layer of cap sheet complying with ASTM D3909 running the full length of the valley. (c) Gutters and downspouts. Gutters and downspouts shall be constructed of noncombustible material. (d) Ventilation openings. Ventilation openings for enclosed attics, enclosed rafter spaces, and under floor spaces shall be in accordance with section 106-51(d)(1) or section 106-51(d)(2) as applicable. (1) Performance requirements. Ventilation openings shall be fully covered with listed vents, tested in accordance with ASTM E2886, to demonstrate compliance with all of the following requirements: (i) There shall be no flaming ignition of the cotton material during the Ember Intrusion Test. (ii) There shall be no flaming ignition during the Integrity Test portion of the Flame Intrusion Test. (iii) The maximum temperature of the unexposed side of the vent shall not exceed 662°F (350°C). (2) Prescriptive requirements. Ventilation openings for enclosed attics, enclosed rafter spaces, and under floor spaces shall be covered with noncombustible corrosion resistant mesh with openings not to exceed 1/8 inch. (e) Exterior wall. Exterior walls shall be limited to the following: (1) Vinyl siding as part of or applied to exterior wall assemblies with a 1-hour-fire-resistance rating, rated for exposure on the exterior side. (2) Vinyl siding over noncombustible sheathing. (3) A wall covered with noncombustible siding. (4) A wall covered with fire-retardant-treated wood siding. (5) A wall covered with siding made of ignition resistant building materials. (6) Mass timber or log wall construction. Such materials shall extend from the top of the foundation to the underside of the eave or the underside of the roof sheathing. Exterior wall coverings shall be labeled for exterior use or shall be covered by a material labeled for exterior use. Exceptions: 1. Exterior wall embellishments and architectural trim (exclusive of trim on exterior windows and doors) not to exceed 5 percent of the square footage of exterior walls. 2. Roof or wall top cornice projections and similar assemblies. 3. Solid wood rafter tails and solid wood blocking installed between rafters having a minimum dimension of 2 inches nominal. (f) Flashing. A minimum of 6 inches of metal flashing or noncombustible material applied vertically between the wall sheathing and the exterior cladding shall be installed at the ground, decking, and roof intersections. Combustible sheathing products exposed by the gap created at the base of the exterior walls, posts, or columns must be protected with noncombustible material or ignition-resistant building materials while still permitting drainage and moisture control from behind exterior cladding. (g) Exterior glazing. Exterior windows, window walls and glazed doors, windows within exterior doors, and skylights shall be tempered glass, multilayered glazed panels, glass block or have a fire protection rating of not less than 20 minutes. (h) Underfloor enclosure. Buildings or structures shall have underfloor areas enclosed to the ground with exterior walls in accordance with Sec. 106-51(e). Exception: Complete enclosure shall not be required where the underside of exposed floors and exposed structural columns, beams and supporting walls are protected as required for exterior one hour fire-resistance-rated construction or mass timber construction or fire-retardant-treated wood. (i) Decks, appendages, and projections. Decks and other unenclosed accessory structures attached tobuildings shall be constructed of materials per the following: (1) Deck surface. Noncombustible material, approved wood thermoplastic composite lumber with an ASTM E84 flame spread index no greater than 200, ignition-resistant building materials or any approved Class A roof assembly. (2) Deck framing. Deck framing shall be constructed of one of the following: (i) One-hour fire-resistance-rated construction. (ii) Mass timber construction. (iii) Approved noncombustible materials. (iv) Fire-retardant-treated wood. (v) Ignition-resistant building materials. (vi) Wood with a minimum nominal thickness of at least two inches for joists and four inches for beams and columns or posts. Multi-ply beams and posts with an equivalent nominal four-inch thickness are allowed. (j) Vehicle access door perimeter gap. Exterior vehicle access door shall resist the intrusion of embers from entering by preventing gaps between doors and door openings, at the head, sill, and jam of doors from exceeding 1/8 inch. Gaps between doors and door openings shall be controlled by one of the following methods. (1) Deck surface. Weather-stripping products made of materials that: (a) have been tested for tensile strength in accordance with ASTM D638 (Standard Test Method for Tensile Properties of Plastics) after exposure to ASTM G155 (Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials) for a period of 2,000 hours, when the maximum allowable difference in tensile strength values between exposed and non-exposed samples does not exceed 10 percent; and (b) exhibit a V-2 or better flammability rating when tested to UL 94 (Standards for Tests for Flammability of Plastic Materials for Parts in Devices and Appliances). (2) Door overlaps onto jams and headers. (3) Garage door jams and headers covered with metal flashing.

(Ord. No. 4923, § 1, 3-24-2026)

Ask a question about Arvada law

Corpus searches the Arvada sections it holds and shows the ones that match, with their citations. Free, no sign-in.