Sec. 106-61. - Class 1 interface requirements.
(a) Structure ignition zone 1 (0—5 feet) - Immediate zone. (1) Objective. This zone is designated to reduce or eliminate ember ignition and direct flame contact with the structure, decks, stairs, and attachments. (2) Materials. Use noncombustible, hard surface materials in this zone, such as rock, gravel, sand, concrete, bare earth or stone/concrete pavers. (3) Plantings. Remove all plantings including shrubs, slash, combustible mulch and other woody debris. (4) Trees. (i) There shall be no planting of new trees in the Immediate Zone. Mature trees of no less than ten-inch diameter at four and one-half feet above ground level may be maintained. (ii) Tree crowns extending to within ten feet of the outermost point of any structure shall be pruned to maintain a minimum clearance of ten feet. (iii) Prune tree branches to a height of six to ten feet from the ground or a third of the total height of the tree, whichever is less. (5) Storage of combustibles. There shall be no storage of firewood or other combustible materials in this area or areas under decks. (b) Structure ignition zone 2 (5—30 feet) - Intermediate zone. (1) Objective. This zone is designed to give an approaching fire less fuel, which will help reduce its intensity as it gets nearer to structures. (2) Dead materials. Within the fuel modification area, hazardous dead plant material must be removed from live vegetation. (3) Fuels accumulation. There shall be no large accumulations of surface fuels such as logs, branches, slash and combustible mulch. Mulch shall not exceed a maximum depth of four inches. Firewood piles must be kept at least 30 feet away from habitable structures unless stored in a noncombustible container or structure comprised of ignition resistant building materials or noncombustible materials. (4) Trees. Tree crowns extending to within ten feet of the outermost point of any structure shall be pruned to maintain a minimum clearance of ten feet. Prune tree branches to a height of six to ten feet from the ground or a third of the total height of the tree, whichever is less. (5) Shrubs. Shrub groups within this zone shall be spaced to prevent structure ignition. Shrubs shall not be planted under trees within the tree drip line. (6) Prohibited plants. Juniperus spp. (Juniper species), Thuja occidentalis (American arborvitae), Thuja orientalis (Oriental Arborvitae) are prohibited. (7) Slope adjustment of the intermediate zone. For tree removals on any slopes of 20 percent or greater, the Wildfire Interface Specialist must provide a report on the appropriate spacing of trees to meet the intent of this Code. (c) Retaining walls. Retaining walls shall be constructed with either noncombustible or ignition-resistant building materials when any of the following conditions exist (1) The retaining wall is within eight feet of a structure regulated by this code or up to the property line when the property line is less than eight feet away from the structure. (2) The retaining wall is integral to the support of a structure regulated by this code. (3) The retaining wall is integral to the egress from a structure regulated by this Code to a public way, easement, or private road. (d) Fencing. Fencing within eight feet of a structure regulated by this code or up to the property line when the property line is less than eight feet away from the structure shall be constructed with noncombustible or ignition-resistant building materials. (e) Site signage. (1) Marking of roads. Approved signs or other approved notices shall be provided and maintained for access roads and driveways to identify such roads and prohibit the obstruction thereof. (2) Marking of fire protection equipment. Fire protection equipment and fire hydrants shall be clearly identified in a manner approved by the code official to prevent obstruction. (3) Address markers. Buildings shall have a permanently posted address, which shall be placed at each driveway entrance and be visible from both directions of travel along the road. In all cases, the address shall be posted at the beginning of construction and shall be maintained thereafter, and the address shall be visible and legible from the road on which the address is located in a manner approved by the code official.
(Ord. No. 4923, § 1, 3-24-2026)
Ask a question about Arvada law
Corpus searches the Arvada sections it holds and shows the ones that match, with their citations. Free, no sign-in.