Sec. 18-418. - IPC - Table 706.3, Fittings for change in direction.
Table 706.3 is hereby amended in its entirety to read as follows: TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION TYPE OF FITTING PATTERN | CHANGE IN DIRECTION HORIZONTAL TO VERTICAL | VERTICAL TO HORIZONTAL | HORIZONTAL TO HORIZONTAL Sixteenth bend | X | X | X Eighth bend | X | X | X Sixth bend | X | X | X Quarter bend | X | —- a | —- a Short sweep | X | —- a,b | —- a Long sweep | X | X | X Sanitary tee | X c | —- | —- Wye | X | X | X Combination wye and eighth bend | X | X | X For SI: 1 inch = 25.4 mm. a. The fittings shall only be permitted for a 2-inch or smaller fixture drain. b. Three inches or larger—fixture drain. c. For a limitation on double sanitary tees, see Section 706.3.
(Ord. No. 4921, § 12, 3-24-2026)