§ 2-1-5-3 — Generally applicable lot and building form standards
Code of Ordinances of the City of Arvada, Colorado (Supp. No. 67: codified through Ordinance No. 4932, enacted May 5, 2026) · Arvada Land Development Code, art. 2-1, § 2-1-5-3
Corpus is an independent public-information project, not the official City of Arvada website. Stable reference: corpuslaw.us/code/8de54a3b-92bc-4c66-ba14-176fec321f16
2-1-5-3. - Generally applicable lot and building form standards.
A. Generally. The provisions of this Section apply to individual building types as provided in Sections 2-1-5-4, Mixed-Use Building Type Lot and Building Form Standards, to 2-1-5-5, Mixed-Use Parking Structure Building Lot and Building Form Standards, inclusive. B. Front Yard Landscaping. Front yard landscaping may include both live plant materials and hardscape plaza or sidewalk areas, but in no case shall the front yard landscaping include areas for vehicle parking. C. Setback Measurement. 1. Front Setbacks. Front setback requirements apply along all street frontages and along the boundaries of McIlvoy Park and Olde Town Plaza. See Figure 2-1-5-3C, Front Setbacks, below. [image omitted; see the official code] 2. Side and Rear Setbacks. Side and rear setbacks are measured from side and rear property lines. 3. Protected area: A protected area is a property in the OT zoning district which contains a single family or duplex building type, or is adjacent to the R-N, R13, or CG zoning districts. D. Setback Encroachments. The setback encroachments allowed in Section 2-1-10-1, Exceptions to Setback Standards, apply in the OT zoning district, except as specifically modified by this Subsection. 1. A cantilevered vertical conveyance system such as steel-framed stairs is allowed to encroach into the front setback, provided that: a. The system will not cause accumulation of snow and ice on or over the public right-of-way; b. The encroachment does not exceed six feet; c. There is 12 feet of clearance from the surface of the sidewalk to the underside of the first structural member. See Figure 2-1-5-3D, Setback Encroachments; and d. A revocable permit is approved by the City, applicable. 2. A protected area is a property in the OT zoning district which contains a single-family or duplex building type or is a property adjacent to the R-N, R13, or CG zoning districts. [image omitted; see the official code] 3. Setback encroachments are not allowed between the front property line and the frontage zone, except for a Cantilevered Vertical Conveyance Systems and as permitted in Section 2-1-10-1, Exceptions to Setback Standards and as permitted in Section 2-10-1, Exceptions to Setback Standards. E. Frontage Zone. 1. Generally. The frontage zone is an area of the subject property within which build-to requirements and additional height limitations may apply, based on subdistrict, building type, and context. See Figure 2-1-5-3E, Frontage Zone. Generally, frontage zone requirements apply along streets, McIlvoy Park and Olde Town Plaza boundaries. 2. Landscape/Hardscape Requirement. The area of the frontage zone that is located between the building and the sidewalk must be landscaped or hardscaped. 3. Variation. In some circumstances, the frontage zone is composed of two distinct areas, which may provide for different requirements for build-to lines or building height, depending upon the distance from the property line. In such cases, the two areas are described as "Area 1," which is the portion of the frontage zone that is closest to the street, and "Area 2," which is the portion of the frontage zone that extends from the interior boundary of Area 1 towards the interior of the subject property. [image omitted; see the official code] F. Build-To. The required build-to percentage specifies the proportion of the width of the frontage zone (see Subsection E. above), that must include a portion of the front building facade. It is measured as a percentage of the property frontage width of the building within the frontage zone divided by the length of the property line along which the frontage zone is established. A recessed entry, covered patio or other similar element that does not affect the fundamental relationship of the building to the street (even if it is not located within the frontage zone) may also be counted in the calculation of this proportion. See Figure 2-1-5-3F, Calculation of Build-To Requirements. [image omitted; see the official code] G. Building Width. Building width is the total building width that is allowed on a lot along a specified elevation. See Figure 2-1-5-3G, Building Width. [image omitted; see the official code] H. Building Height. 1. Measurement. Building height is measured as defined in Article 11-1-1. [image omitted; see the official code] 2. Number of Stories. a. In addition to the building height, the number of stories permitted are established. Section 2-1-5. For the purposes of this Division, the relationship between stories and feet is set out in Table 2-1-5-3H, Olde Town Number of Stories. All height specifications in this Division that refer to "story" or "stories" also incorporate the "feet" measurements of Table 2-1-5-3H, Olde Town Number of Stories. Notwithstanding the dimensional height limits established in Table 2-1-5-3H, maximum height shall be historically accurate as determined through application of the Design Guidelines for Olde Town. Table 2-1-5-3H: Number Stories Stories | Feet 1 story | 15 ft. 2 stories | 28 ft. 3 stories | 42 ft. 4 stories | 55 ft. 5 stories | 65 ft. b. Space within a roof form counts as a story if 50 percent or more of the floor area has a clear height of seven and one-half feet or more, measured from the finished floor to the finished ceiling. See Figure 2-1-5-3H2, Attic Story. [image omitted; see the official code] I. Floor Height. 1. Ground floor elevation is measured from the average sidewalk level to the top of the finished ground floor. 2. Ground story floor height is measured from the top of the finished floor to the ceiling above. 3. Minimum ground story floor height applies only to the first 30 feet of building depth. See Figure 2-1-5-3I, Ground Story Height Measurement. [image omitted; see the official code] J. Transparency. 1. Transparency refers to the minimum percentage of a building's width devoted to transparent windows and doors (clad or opaque windows and doors do not count toward the transparency requirements). 2. This standard does not count ground story windows or doors that do not equal at least one-half of the floor height, or upper story windows or doors that do not equal at least one-third of the floor height. See Figure 2-1-5-3J, Building Transparency. 3. The standard applies only on street-facing, McIlvoy Park-facing, and Olde Town Plaza-facing facades (as provided in the individual sections of this Division), and not interior or rear-facing facades. [image omitted; see the official code] K. Blank Wall. 1. Blank wall area means the width of any story of a street-facing wall that does not include a: a. Substantial material change (paint color is not considered a substantial change); b. Window or door; or c. Column, pilaster, or other articulation greater than 12 inches in depth. See Figure 2-1-5-3K, Blank Wall Area. 2. Blank wall area standards apply to ground story and upper story facades that face adjoining streets, McIlvoy Park, or Olde Town Plaza, as provided in the individual sections of this Division. [image omitted; see the official code] L. Building Entrances. 1. An entrance providing both ingress and egress, operable to residents or customers at all times, is required if a street-facing, Olde Towne Plaza facing or McIlvoy Park-facing entrance is required. See Figure 2-1-5-3L, Building Entrance. 2. Additional entrances from another street, pedestrian area or internal parking area are also permitted. 3. An angled entrance that is provided at the corner of a building at the intersection of two streets or of a street and McIlvoy Park or Olde Town Plaza meets the entrance requirements for both streets, or the street and park or plaza. [image omitted; see the official code] M. Transparent Screening Device. 1. A Transparent Screening Device is a mostly transparent device used to screen parking on an upper levels of a Mixed-Use Parking Structure building type. See Figure 2-1-5-3M, Screening on Mixed-Use Parking Structure. [image omitted; see the official code]
(Ord. No. 4905, §§ 5, 6, 8-19-2025)
Ask a question about Arvada law
Corpus searches the Arvada sections it holds and shows the ones that match, with their citations. Free, no sign-in.
