§ 22-144 — Subflooring

City Code of the City of Aurora, Colorado (Aurora City Code current through Ordinance 2026-42, passed August 10, 2026 (municipal.codes publication, scraped 2026-11-17)) · Aurora City Code § 22-144

Corpus is an independent public-information project, not the official City of Aurora website. Stable reference: corpuslaw.us/code/76faee47-877e-4823-8c7b-ef40f3ddd42c

Sec. 22-144. Subflooring.

Section 310 of the IBC adopted in section 22-131 is amended by adding the following: All subflooring in new type R occupancies shall be attached to structural members by both screws and glue or shall be of tongue and groove type with attachment by screws or ring shank nails. All such installations shall be in compliance with the building code and manufacturer's recommendations for the utilized materials.

Ask a question about Aurora law

Corpus searches the Aurora sections it holds and shows the ones that match, with their citations. Free, no sign-in.