Sec. 22-186. Climatic and geographic design criteria.

Table R301.2(1), "Climatic and Geographic Design Criteria," of the IRC is amended to read as follows: Ground Snow Load: 40 pounds per square foot. Wind design: Wind Speed for Risk Category I Structures: 100 miles per hour for 3-second gust Wind Speed for Risk Category II Structures: 105 miles per hour for 3-second gust Wind Speed for Risk Category III Structures: 110 miles per hour for 3-second gust Wind Speed for Risk Category IV Structures: 115 miles per hour for 3-second gust Topographic Effects: No Special Wind Region: Yes Wind-Borne Debris Zone: No Seismic Design Category: B Subject to Damage from Weathering: Severe Frost Line Depth: 36 inches Subject to Damage from Termite: Slight to moderate Subject to Damage from Decay: None to slight Winter Design Temperature: 1 Degree (F) Ice Shield Underlayment required: Yes Flood Hazards: Varies, refer to City of Aurora Code, Chapter 70 Air Freezing Index: 712 Mean Annual Temperature: 50.3 Degrees F