Sec. 90-174. Required inspections.
Section 305(e)1.A of the guidelines adopted in section 90-166 is amended to read as follows: (a) Foundation inspection: To be made (when applicable). 1. Caisson (pier) inspection: After the caisson has been drilled and before concrete is placed (special inspection required). 2. Footing inspection: After excavation is complete, forms are in place and before concrete is placed. 3. Reinforcing inspection: After steel is in place and before concrete is placed. 4. Foundation and waterproofing: After waterproofing is applied and before backfilling is started.