9-7-2. - Setback Standards.

(a) Front, Rear, and Side Yards: Front, rear, and side yards shall be identified consistent with the yard definition in Section 9-16-1, B.R.C. 1981. (b) Front Yard Setback Reductions: The front yard setback required in Section 9-7-1, "Schedule of Form and Bulk Standards," B.R.C. 1981, may be reduced for a principal structure on any lot if more than fifty percent of the principal buildings on the same block face or street face do not meet the required front yard setback. The setback for the adjacent buildings and other buildings on the block face shall be measured from the property line to the bulk of the building, excluding, without limitation, any unenclosed porches, decks, patios or steps. The bulk of the building setback shall not be less than the average bulk of the building setback for the principal buildings on the two adjacent lots. Where there is only one adjacent lot, the front yard setback reduction shall be based on the average of the principal building setbacks on the two closest lots on the same block face. (See Figure 7-1 of this section.)

![Figure 7-1: Setback Averaging Example](https://figures.74-208-44-221.nip.io/boulder/496676/2bbd30d12fec948a9a0ec6d89d935de6c94b069ec5436e5d13b69fd0395dcad7.png)

Figure 7-1: Setback Averaging Example In this example, lots "B" through "F" are the face block. Lot "A" is not included in the face block, as the front of this lot is on a different street. Setback averaging is measured to the bulk of the buildings and does not include porches. Assuming this block is zoned RL-1, the minimum required front yard setback would be twenty-five feet. The block face shown would qualify for setback averaging, as more than fifty percent of the principal buildings do not meet the required front yard setback. An addition to the front of lot "E" would require the averaging of the setbacks of lots "D" and "F", the two closest buildings on the same block face. In this example the resulting setback would be 20 feet - the average of lot "D" (fifteen feet) and lot "F" (twenty-five feet). An addition to the front of lot "F" would be based on the average of the two closest buildings on the same block face; in this case, lots "D" and "E." (c) Side Yard Setback Standards: (1) Maintenance Easements Required in Residential Zoning Districts: In residential zoning districts that allow a zero side yard or rear yard setback, the applicant shall be required to secure a recorded maintenance easement from the adjoining property owner if the zero setback side is not attached to another structure. The easement shall be effective for the life of the building. The easement shall not be less than three feet in width measured parallel to that portion of the building at zero setback. (2) Wall Height for Residential Zero Lot Line: The maximum wall height for detached dwelling units at the zero setback property line shall be twelve feet. Townhouses, consistent with Subparagraph (7), below, are not subject to this restriction. (3) Calculating Residential Zero Lot Line Side Yard Setbacks: For detached dwelling units, the side yard setback opposite the zero setback property line shall be the sum of both side yards for the district. (4) Combined Side Yard Setbacks: When combined side yard setbacks are required by Section 9-7-1, "Schedule of Form and Bulk Standards," B.R.C. 1981, the resulting structure, including the existing structure and any addition, must meet the combined side yard setback requirements. (See Figure 7-2 of this section for compliant and noncompliant examples.)

![Figure 7-2: Combined Side Yard Setbacks](https://figures.74-208-44-221.nip.io/boulder/496676/ce1da41c6bc310a14687190980ef30720004aa139b7f8d432324af5914c9e660.png)

Figure 7-2: Combined Side Yard Setbacks Example: In the RL-1 district, the combination of side yard setbacks must be no less than fifteen feet, with a minimum of five feet. Both existing structures and additions (hatched) are included in the calculation. (5) Existing Nonstandard Side Yard Setbacks for Existing Detached Dwelling Units: A second story addition that does not comply with the minimum interior or combined side yard setbacks may be added to an existing detached dwelling unit subject to the following: (A) The interior side yard setback for the existing detached dwelling unit complied with the setback requirements in existence at the time of initial construction and was not created by a variance or other procedure; (B) The resulting interior side yard setback will not be less than five feet and combined side yard setbacks will not be less than ten feet; (C) That portion of the building in the side yard setback shall vertically align with the existing first-story wall. (6) Townhouses: There is no minimum side yard setback from an interior lot line between one townhouse and an adjoining townhouse. (7) Setback Relative to Building Height: For buildings subject to the side yard setback requirements based on building height, the setback shall be determined consistent with Figure 7-3. For the purposes of this subparagraph, wall height shall be measured from finished grade as follows: (A) Sloped roofs shall be measured from adjacent finished grade to the point where the vertical wall intersects with the sloped roof. (B) Flat roofs shall be measured from adjacent finished grade to the top of the parapet. (C) Window wells or door wells as described under Subparagraph 9-8-2(e)(1)(D) shall not be counted as part of the wall height.

![Figure 7-3. Setback Relative to Building Height](https://figures.74-208-44-221.nip.io/boulder/496676/0257ed6b1a11619e7d59b343dc0eebd95d45d1b0d8e5c8ecf017e30f02ee9c89.png)

Figure 7-3. Setback Relative to Building Height (d) Rear Yard Setbacks: Where a rear yard backs on a street, the rear yard shall have a minimum landscaped setback equal to the minimum front yard landscaped setback from a street for all buildings and uses required for that zone. (e) Open Parking Areas, Flagpoles, and Detached Garages and Carports: Open parking areas, flagpoles, and detached garages and carports may be located in compliance with either the required principal building setbacks or accessory building setbacks. (f) Swimming Pools, Spas, and Hot Tubs: Swimming pools, spas, and hot tubs shall be located according to the applicable accessory structure setbacks on a lot except that pools, spas, or hot tubs may be located in compliance with the required front yard principal building setback. (g) Oil and Gas Operations and Other Uses: Oil and gas operations shall be set back from any residential use, residential zone, school, daycare center, hospital, senior living facility, assisted living facility, outdoor venue, playground, permanent sports field, amphitheater, public park and recreation use, or other similar public outdoor facility, but not including trails or City of Boulder open space, in accordance with the standards of Section 9-6-7(b)(2), B.R.C. 1981. No residential use, school, daycare center, hospital, senior living facility, assisted living facility, outdoor venue, playground, permanent sports field, amphitheater, public park and recreation use, or other similar public outdoor facility, but not including trails or City of Boulder open space, shall be located closer than two thousand feet from any single-well well pad of an oil and gas operation in pre-production, closer than two thousand five hundred feet from any multi-well well pad of an oil and gas operation in pre-production, closer than five hundred feet from any well pad of an oil and gas operation in production, and closer than two hundred fifty feet from an oil and gas operation that has been capped and abandoned pursuant to the requirements of Section 9-6-7(b)(16), B.R.C. 1981. Ordinance Nos. 5623 (1994); 5656 (1994); Supplement No. 46 (1995); 5971 (1998); 7079 (2000); 7182 (2002); 7484 (2006); Ord. 7589 (2008); 7738 (2010); 8409 (2020); 8514 (2021); 8523 (2022); 8599 (2024); 8620 (2024); 8651 (2025); 8697 (2025); 8745 (2026)