For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 13-12-210 — Fats, oil and grease (FOG) control, and petroleum, oil and sand (POS) control requirements

Municipal Code of the City of Brighton, Colorado (Codified through Ordinance No. 2508, adopted June 16, 2026. (Supp. No. 26, Update 2)) · Brighton Municipal Code § 13-12-210

Corpus is an independent public-information project, not the official City of Brighton website. Stable reference: corpuslaw.us/code/9f6d2647-4f51-4d45-93a6-08ef6410b19a

Sec. 13-12-210. - Fats, oil and grease (FOG) control, and petroleum, oil and sand (POS) control requirements.

(a) Applicability. FOG and/or POS control requirements shall apply to the following facilities: (1) FOG facilities: All commercial food service, manufacturing or processing establishments, including but not limited to restaurants, cafes, fast food outlets, pizza outlets, delicatessens, sandwich shops, school cafeterias, nursing homes kitchens or any other facility that use one (1) or more of the following preparation activities: cooking by frying, baking, grilling, sauteing, rotisserie cooking, broiling, boiling, blanching, roasting, toasting or poaching. Also included are infrared heating, searing, barbecuing and any other food preparation activity that produces fat, oil or grease by-products in or on a receptacle that requires washing. (2) POS facilities: All petroleum, oil, sand or grit-generating facilities, including but not limited to automotive service or repair garages, machine shops, car-washing facilities, automotive care centers, auto body shops and also hydraulic elevator pits. (3) Any other facility which, in the opinion of the Director, discharges floatable grease in excessive amounts specified in Paragraph 13-l2-170(b)(8), or substantial amounts of sand or other debris or pollutant into the POTW, including but not limited to sand recovery, laundries, bottling establishments, slaughterhouses and hair salons, which may be harmful to, or cause obstruction in, the wastewater collection system, or cause or contribute to interference or pass-through. (b) Exemptions. FOG and/or POS control requirements shall not be required for private living quarters or dwelling units. (c) Installation requirements. Any FOG and/or POS facility shall be required to install and operate an adequately sized grease interceptor and/or sand-oil separator at the user's expense. The use of alternative pretreatment device, such as, but not limited to, indoor or under-the-sink grease traps, oil traps or sand traps, does not satisfy the requirements of this Article and shall not be accepted in lieu of exterior grease interceptors and/or sand-oil separators unless a variance has been granted in writing by the Department. (d) Plan design and review. (1) The user, or an authorized representative thereof, seeking a building permit for a business or establishment specified in Paragraphs 13-12-210(a)(l), (2) and (3) shall submit to the Department, prior to issuance of the building permit, an application for a plan review to determine the need, method, size and location of the interceptor and/or separator required to control discharges into the POTW. The form for such application shall be provided by the department, and submission shall include detailed plans describing such facilities, proposed plumbing fixtures, manufacturer's specifications and operating procedures, and such other materials as may be specified on the application or required by the Director in order to review and recommend the requested approval and permit. (2) The review of such documents shall in no way relieve the user from the responsibility of modifying such facilities as necessary to produce a discharge acceptable to the Director under the provisions of this Article. Written approval from the Director must be obtained prior to installation of the interceptors and/or the separators. (3) The design, sizing and installation of grease interceptors and/or sand-oil separators shall be in accordance with the City's adopted plumbing codes, City of Brighton Standard and Specification Manual, applicable codes, ordinances and policies of the City, the manufacturer's installation instructions and the policies of the Director to accomplish their intended purposes of intercepting pollutants from the user's wastewater and preventing the discharge of pollutants into the City's POTW. (4) Toilets, urinals and similar fixtures shall not discharge waste through a grease interceptor and/or sand-oil separator. Such fixtures shall be plumbed directly into the building sewer. Grease interceptors and/or sand-oil separators shall have gas-tight covers and be properly vented in accordance with the adopted plumbing code. (5) In traffic areas, the interceptor or separator shall be designed to have adequate reinforcement and cover (including piping), meeting traffic-loading specifications. (6) All grease interceptors shall have at least two (2) compartments and a minimum capacity of at least three hundred twenty-five (325) gallons for a facility without a dishwasher, and seven hundred fifty (750) gallons for a facility with a dishwasher. The grease interceptor shall not exceed a capacity of three thousand (3,000) gallons. If the calculated capacity exceeds three thousand (3,000) gallons, then multiple units plumbed in series shall be installed. Waste in excess of one hundred forty (140) degrees Fahrenheit shall not be discharged into a grease interceptor. All food grinders shall discharge into a grease interceptor. (7) All sand-oil separators shall have at least two (2) compartments and a minimum capacity of at least three hundred (300) gallons. The maximum individual separator size shall be two thousand five hundred (2,500) gallons. If the calculated capacity exceeds two thousand five hundred (2,500) gallons, then multiple units plumbed in series shall be installed. (e) Existing facilities. (1) The Director shall notify any existing facility and/or establishment identified in Paragraphs 13-12-210(a)(l), (2) and (3), which is required to be connected to an interceptor and/or separator, but are not so connected, of the requirements for connection and continued failure to do so is a violation of this Article. (2) The notice shall be in writing and served on the user personally, and by regular mail, postage prepaid, to the person whose name appears on the user's utility billing account with the City. A copy of the notice shall also be posted on the premises. Such notice of violation shall require the user to install at his or her own expense such interceptor and/or separator at the earliest to occur of: a. A change of ownership of the property, or operation of the establishment or facility; b. Upon the construction of any improvement to the building housing the establishment of facility; or c. Three hundred sixty-five (365) days from the date of the notice of violation. (3) Pending installation of the required interceptor and/or separator, the existing user shall: a. Provide quarterly cleaning of the facility's private sanitary service line to prevent the buildup of fat, cooking oil and grease, and/or petroleum, oil, sand, grit, cloth, buttons and/or other materials or solids that cause clogging; b. Submit records of each sanitary sewer line cleaning to the City upon request; c. Pay a surcharge fee to cover the costs incurred by the City for accelerated sanitary sewer line cleaning on the City's sanitary sewer line providing service to the user, as provided in Section 13-16-50 of this Chapter; d. Install and maintain alternative pretreatment device, such as, but not limited to, grease traps, oil traps and sand traps. Grease traps should be sized adequately, with a minimum capacity of at least one hundred fifty (150) pounds, flow of seventy-five (75) gallons per minute, or sixty (60) gallon liquid holding capacity; and e. Provide to the Director, upon request, proof of use of the adequate Best Management Practices (BMPs), such as, but not limited to, scraping food from plates into garbage cans, collection of liquid oil and grease from pots into waste containers, sweeping of floors, containment of spills, training of staff and/or other practices identified by the Director. (f) Variance or waiver of grease interceptor and/or sand-oil separator installation requirements. A user or authorized representative thereof may request that the Director grant a variance from the grease interceptor and/or sand-oil separator requirements to allow alternative pretreatment technology in lieu thereof, if the user demonstrates that the alternative equals or exceeds the effectiveness of a required interceptor and/or separator, and that it is impossible or impracticable to install, operate or maintain a required interceptor and/or separator. The Director's determination to grant a variance will be based upon, but not limited to, evaluation of the following conditions: (1) There is no adequate space for installation and/or maintenance of the required interceptor and/or separator; (2) There is no adequate slope for gravity flow between kitchen or shop plumbing fixtures and the interceptor/separator and/or between the interceptor/separator and the private sanitary sewer collection lines or public sanitary system; or (3) The user can prove that the alternative pretreatment technology is equally or more effective that the required interceptor or separator in controlling oil, grease, sand, cloth, buttons, glass and discharge of other materials or solids that cause clogging. In addition, the user must be able to demonstrate, after installation of the proposed alternative pretreatment, its effectiveness to control such discharges through downstream visual monitoring of the public sanitary sewer for at least three (3) months, at its own expense. A variance may be granted if the results show no visible accumulation of oil, grease, sand, cloth, buttons, glass and other materials or solids that cause clogging in its building sewer, lateral sanitary sewer and/or main sanitary sewer lines. Any variance issued pursuant to this Section may be revoked at any time in the discretion of the Director. (g) Conditional waiver of requirement to install interceptor, separator or trap. A conditional waiver of requirement to install interceptor, separator or trap may be granted if the Director determines that the establishment or facility will produce negligible discharges and insignificant impact to the public sanitary sewer. Although a waiver from installation of an interceptor, separator and/or alternative device may be granted, the user may be required to provide space and plumbing segregation for future installation of an interceptor, separator and/or alternative device. The Director's determination to grant or revoke a conditional waiver shall be based upon, but not limited to, evaluation of the following conditions: (1) Quantity of oil, grease, sand, cloth, buttons, glass and other materials or solids that cause clogging and/or discharges as measured or indicated by the size of the use based on water usage, menu, seating capacity, number of meals served, amount of on-site consumption of prepared food, number of plumbing fixtures and other conditions that reasonably show to contribute to the discharges; (2) Adequacy of implementation of BMPs and compliance history; (3) Sewer size, grade, condition based on visual and other information, discharges to the sanitary sewer by the user and history of maintenance and adverse discharges caused by oil, grease, clothes, buttons, glass and other materials or solids that cause clogging by the user's discharge; (4) Changes in operations that significantly affect discharges and the operation of the POTW; and (5) Any other condition that the Director deems reasonably related to the generation of adverse discharges. (h) Waiver of interceptor and/or separator installation requirements with a disposal mitigation fee. Where the installation of an interceptor and/or separator is not feasible and no equivalent alternative pretreatment can be installed, a user may be granted a waiver of the interceptor and/or separator requirement upon the payment of a grease disposal mitigation fee as set by the City Council in the annual fee resolution. Additional requirements may also be imposed to mitigate the discharge of oil, grease, sand, cloth, buttons, glass and other materials or solids that cause clogging in the POTW. The Director's determination to grant the waiver upon the payment of a disposal mitigation fee will be based upon, but not limited to, evaluation of the following conditions: (1) There is inadequate space for installation and/or maintenance of the required interceptor, separator and/or alternate pretreatment device. (2) There is inadequate slope for gravity flow between the plumbing fixtures of the facility or establishment and the interceptor, separator and/or alternate pretreatment device and the private sanitary sewer collection lines or the POTW. (i) Application for variance or waiver of requirements for interceptor, separator or traps. A user, or authorized representative thereof, may submit to the Department an application for variance or waiver from the interceptor, separator and/or trap requirement. The user bears the burden of demonstrating that the installation of the required interceptor, separator and/or trap is not feasible or otherwise required. Upon determination by the Director that reasons are sufficient to justify a variance or waiver, approval thereof will be issued or revised to include the variance or waiver and relieve the user from the requirement. (j) Terms and conditions of variance or waiver. A variance or waiver shall contain the terms and conditions that serve as the basis of its issuance. A variance or waiver may be revoked by the Director at any time upon his or her determination that any of the terms and conditions for its issuance are not satisfied or if the conditions upon which the variance or waiver was based have changed so that the justification for the variance or waiver no longer exists. The variance or waiver shall be valid so long as the user remains in compliance with the terms and conditions until the expiration date specified in the variance or waiver. (k) Appeal. The applicant or user may appeal the denial of a variance or waiver to the Board of Appeals as provided in the plumbing code adopted by the City. (l) Maintenance frequency. Interceptors and/or separators shall be kept in continuous operation by the user at all times and shall be inspected and cleaned on a regular basis by the user at his or her own expense as required for efficient operation. (1) Grease interceptors in service shall be cleaned at a maximum interval of ninety (90) days. (2) Sand-oil separators in service shall be cleaned at a maximum interval of one hundred twenty (120) days. (3) Grease traps in service shall be cleaned at a maximum interval of seven (7) days. (m) Maintenance frequency variance. A variance from this maintenance frequency requirement may be obtained when the user can demonstrate that less frequent cleaning is sufficient. The Director may also require more frequent cleaning to users that do not pass maintenance inspections. (n) Maintenance requirements. (1) In maintaining of these interceptors, separators and/or traps, the user shall be responsible for the proper removal and disposal by appropriate means of the captive material and shall maintain records of the dates and means of disposal, which must be kept for at least three (3) years and are subject to review by the Director. Any removal and hauling of the collected materials not performed by the user's personnel must be performed by currently licensed waste disposal firms. Certificates of inspection and maintenance shall be kept on the premises of the interceptor, separator or trap installation and shall be made readily available to City personnel for review and inspection. (2) It is unlawful for any person to withdraw wastes from grease interceptors, grease traps, sand-oil separators, sand traps, oil traps or other similar waste collection devices and to reinject any portion thereof into the wastewater system or a private sanitary sewer facility directly or indirectly connected to the POTW, except at a designated disposal facility approved by the Director. (3) Users shall be subject to the remedies, including penalties, set forth in Sections 13-12-310 through 13-12-330 of this Chapter. In the event a grease interceptor and/or sand-oil separator is not properly maintained by the user, the City may authorize such maintenance work be performed on behalf of the user. The costs of such maintenance work shall be surcharged to the user as provided in Section 13-16-50 of this Chapter, and added to the user's sanitary sewer billing and collected in accordance with sewer billing collection procedures. (o) User's responsibilities. The user shall; (l) Ensure interceptors and/or separators are easily accessible for inspection, cleaning and servicing; (2) Maintain interceptors and/or separators at the user's expense and keep interceptors and/or separators in efficient operating conditions; (3) Document each pump or cleaning event with a waste manifest or invoice which must be kept for at least three (3) years; (4) Take reasonable steps to assure that all waste is properly disposed of at an approved facility in accordance with federal, state and local regulations; and (5) Use adequate Best Management Practices (BMPs) such as, but not limited to, scraping food from plates into garbage cans, collection of liquid oil and grease from pots into waste containers, sweeping of floors, containment of spills, training of staff and/or other practices identified by the City. (p) Director's responsibilities. The Director shall; (l) Conduct periodic inspections of any facility with or without prior notification for compliance with this Article; and (2) Notify the user of any additional required maintenance or repairs in writing. Upon written notification by the Director, the user shall be required to perform corrective actions within the time period established by the Director. (q) Interceptor/separator abandonment. Interceptors and separators abandoned in place shall be cleaned of all debris (grease, sand, oil, etc.), the inlet and outlet pipe plugged at each end, then filled with gravel and the access area sealed, to not permit any entry into the tank.

(Ord. 1271 Art. IV §6, 1987; Ord. 1735 §4, 2002; Ord. 2113 §4, 2011)

Ask a question about Brighton law

Corpus searches the Brighton sections it holds and shows the ones that match, with their citations. Free, no sign-in.