§ 15-10-30 — Amendments to the International Fire Code

Municipal Code of the City of Brighton, Colorado (Codified through Ordinance No. 2508, adopted June 16, 2026. (Supp. No. 26, Update 2)) · Brighton Municipal Code § 15-10-30

Corpus is an independent public-information project, not the official City of Brighton website. Stable reference: corpuslaw.us/code/14c730ed-dc9b-4316-8411-a7fa73b981b8

Sec. 15-10-30. - Amendments to the International Fire Code.

(a) Whenever the term "fire code official" or similar title is used in the International Fire Code, including the appendices thereto as hereby adopted, the term "Fire Chief of the Brighton Fire Rescue District" or "Fire Chief of the South Adams Fire Protection District," shall be inserted in lieu thereof, as appropriate. (b) Section 101.1 of the International Fire Code is hereby amended as follows: 101.1 Title. These regulations shall be known as the Fire Code of the City of Brighton, Colorado, and hereinafter referred to as "this code." (c) Subsection 105.5.32 of the International Fire Code is hereby amended as follows: A permit is required for mobile food preparation vehicles equipped with appliances that produce smoke or grease-laden vapors. A mobile food preparation vehicle means a motorized or towed wheeled vehicle that is designed, equipped, and used to prepare or serve and sell food. (d) Subsection 105.6.25 of the International Fire Code is hereby enacted as follows: 105.6.25. Flammable and combustible liquids. A permit is required to install, alter, remove, abandon, or otherwise dispose of a flammable or combustible liquid tank. (e) Section 109.3 of the International Fire Code is hereby amended as follows: 109.3 Recordkeeping. (a) A record of periodic inspections, tests, servicing, and other operations and maintenance shall be maintained on the premises or other approved location for not less than 3 years, or a different period of time where specified in this code or referenced standards. Records shall be made available for inspection by the fire code official, and a copy of the records shall be provided to the fire code official on request. The fire code official is authorized to prescribe the form and format of such recordkeeping. The fire code official is authorized to require that certain required records be filed with the fire code official. (b) All licensed contract companies shall submit inspections, tests, and service reports through The Compliance Engine, a cloud-based, electronic program for recordkeeping of the fire protection system reports for Brighton Fire Rescue District. Fire protection contractors shall submit service reports and shall register with The Compliance Engine. Contractors shall submit all complaints and deficient inspection, testing, and maintenance reports as soon as possible, but no later than 12 days after the service date. System impairment reports shall be submitted immediately. (f) Section 111.2 of the International Fire Code is hereby amended as follows: 111.2 Limitations on authority. An application for appeal shall be based on a claim that the true intent of this code or the rules legally adopted thereunder has been incorrectly interpreted, the provisions of this code do not fully apply, or an equivalent or better form of construction is proposed. The appeals hearing officer shall not have authority to waive requirements of this code or interpret the administration of this code. (g) Section 113.4 of the International Fire Code is hereby amended as follows: 113.4 Violation penalties. If the notice of violation is not complied with promptly, the building official is authorized to request the legal counsel of the jurisdiction to institute the appropriate proceeding at law or in equity to restrain, correct or abate such violation, or to require the removal or termination of the unlawful occupancy of the building or structure in violation of the provisions of this code or of the order or direction made pursuant thereto. (h) Section 307.6 of the International Fire Code is hereby enacted as follows: 307.6 Prohibitions. Open burning is prohibited on windy days in which surface wind speeds exceed 10 miles per hour or, if a particular wind direction results in a hazardous fire or smoke condition, as determined by the fire code official. (i) Section 307.7 of the International Fire Code is hereby enacted as follows: 307.7 Open burn hours. Unless an alternative time has been approved by the fire code official, opening burning shall commence only after sunrise and conclude upon sunset. (j) Section 308.1.4 of the International Fire Code is hereby amended as follows: 308.1.4 Open-flame cooking devices. Charcoal burners and other open-flame cooking devices shall not be operated on combustible balconies or within 10 feet (3048 mm) of combustible construction. (k) Section 403.11.1 of the International Fire Code is hereby amended as follows: 403.11.1. Fire watch personnel. Where, in the opinion of the fire code official, it is essential for public safety in a place of assembly or any other place where people congregate, because of the number of persons, or the nature of the performance, exhibition, display, contest or activity, the owner, agent or lessee shall provide one or more fire watch personnel, as required and approved. Fire watch personnel shall comply with Sections 403.11.1.1 and 403.11.1.2. Public notice of a building under fire watch may be required at the discretion and as required by the fire official. (l) Section 503.2.7 of the International Fire Code is hereby amended as follows: 503.2.7 Grade. The grade of a fire apparatus access road shall not exceed 7%. The grade of an aerial fire apparatus access road shall not exceed 5%. (m) Section 503.6.1 of the International Fire Code is hereby enacted as follows: 503.6.1 Electric security gates. Electrically operated security gates installed in areas of residential occupancy shall have the following means of emergency operation: (1) an approved key switch; (2) automatic opening upon power loss; (3) the capability to be manually opened. (n) Section 505.1 of the International Fire Code is hereby amended as follows: 505.1 Address identification. New and existing commercial and industrial buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 6 inches (152.4 mm) high with a minimum stroke width of ¾ inch (19.05 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole, or other sign or means shall be used to identify the structure. Address identification shall be maintained. (o) Section 506.1 of the International Fire Code is hereby amended as follows: 506.1 Where required. Where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire-fighting purposes, the fire code official is authorized to require all buildings and facilities with a monitored fire protection system to maintain a Knoxbox key box to be installed in an approved location. The Knoxbox key box shall be of an approved type listed in accordance with UL 1037 and shall contain keys to gain necessary access as required by the fire code official. (p) Section 507.5 of the International Fire Code is hereby amended as follows: 507.5 Fire hydrant systems. Fire hydrant systems shall comply with Sections 507.5.1 through 507.5.6. All newly placed fire hydrants shall have one 5-inch hose connection with threadless couplings that are compatible with fire department hoses. (q) Section 5704.2.9.6.1 of the International Fire Code is hereby amended as follows: 5704.2.9.6.1. Locations where above-ground tanks are prohibited. Storage of Class I and II liquids in above-ground tanks outside of buildings is prohibited within the corporate limits of the City of Brighton. (r) Section 1103.5.3 of the International Fire Code is hereby amended as follows: 1103.5.3 Group 1-2, Condition 2. In addition to the requirements of Section 1103.5.2, existing buildings of Group 1-2, Condition 2 occupancy shall be equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1. The automatic sprinkler system shall be installed. (s) Section 5706.2.4.4 of the International Fire Code is hereby amended as follows: 5706.2.4.4. Locations where above-ground tanks are prohibited. Storage of Class I and II liquids in above-ground tanks outside of buildings is prohibited within the corporate limits of the City of Brighton. (t) Section 5806.2 of the International Fire Code is hereby amended as follows: 5806.2 Limitations. Storage of flammable cryogenic fluids in stationary containers outside of buildings is prohibited within the corporate limits of the City of Brighton. (u) Section 6104.2 of the International Fire Code is hereby amended as follows: 6104.2 Maximum capacity within established limits. The aggregate capacity of any one installation within the corporate limits of the City of Brighton shall not exceed a water capacity of 2,000 gallons (7570 L).

(Ord. 2485 §19, 2025)

Ask a question about Brighton law

Corpus searches the Brighton sections it holds and shows the ones that match, with their citations. Free, no sign-in.