§ 15-12-30 — Amendments to the International Residential Code
Municipal Code of the City of Brighton, Colorado (Codified through Ordinance No. 2508, adopted June 16, 2026. (Supp. No. 26, Update 2)) · Brighton Municipal Code § 15-12-30
Corpus is an independent public-information project, not the official City of Brighton website. Stable reference: corpuslaw.us/code/0423c81b-cb75-4a12-97af-3819873a47e6
Sec. 15-12-30. - Amendments to the International Residential Code.
(a) Section R101.1 of the International Residential Code is hereby amended as follows: R101.1 Title. These provisions shall be known as the Residential Code for One- and Two-family Dwellings of the City of Brighton and shall be cited as such and will be referred to herein as "this code." (b) Section R102.8 of the International Residential Code is hereby amended as follows: R102.8 Requirements not covered by this code. Requirements necessary for the strength, stability, or proper operation of an existing or proposed structure or site, or for the public safety, health, and general welfare, not specifically covered by this code, shall be determined by the code official. (c) Building subsection (2) of R105.2 of the International Residential Code is hereby amended as follows: 2. Fences not over 3 feet high. (d) Building subsection (11) of Section R105.2 of the International Residential Code is hereby enacted as follows: 11. Removal and replacement of electrical and plumbing fixtures, such as outlets, switches, breakers, toilets, and sinks, in the same location are to be treated as repairs and do not require permitting when the electrical or plumbing infrastructure is not otherwise extended or altered. This exception is not to be construed as exempting electrical panels, mechanical appliances, or similar devices governed by code. (e) Subsection R105.3.2.1 of the International Residential Code is hereby enacted as follows: R105.3.2.1. Allowable submittal. Permit applications must be accompanied by a complete set of construction documents, except for approved deferred submittals. Unless otherwise agreed upon for model homes, no permit applications shall be accepted prior to completion of all entitlements and/or after initial acceptance of all public infrastructure. (f) Subsection R106.1.1.1 of the International Residential Code is hereby enacted as follows: R106.1.1.1 Engineering required. Where a proposed structure is 400 sq ft or larger or an existing structure is proposed to become habitable space, construction documents must be prepared by a registered design professional. (g) Section R108.7 of the International Residential Code is hereby enacted as follows: R108.7 Permit valuations. The applicant for a permit shall provide an estimated permit value at the time of application unless otherwise specified in the fee resolution. Permit valuations shall reflect the total value of work, including materials and labor, for which the permit is being issued. If, in the opinion of the building official, the valuation is incorrect, the permit shall be denied unless the applicant can produce detailed estimates to the building official substantiating the valuation. Final building permit valuation shall be set by the building official. (h) Section R111.1 of the International Residential Code is hereby amended as follows: R111.l Connection of service utilities. A person shall not make connections from a utility, a source of energy, fuel, or power to any building or system that is regulated by this code for which a permit is required, until approved by the building official. Each lot and/or single-family unit is to have one tap, one shut-off, and one meter specifically for that unit and independent utilities supplied and connected, without passing through other single-family unit structures unless technically infeasible to do otherwise and approved by the building official. This applies to gas, electric, water, sewer, and similar utilities. (i) Section R301.2 of the International Residential Code is hereby amended as follows: R301.2 Climatic and geographic design criteria. Buildings shall be constructed in accordance with the provisions of this code as limited by the provisions of this section. Additional criteria shall be established by the building official for the duration of the code cycle and published in a manner readily accessible to the public. (j) Section R313.2 of the International Residential Code is hereby amended as follows: R313.2 One- and two-family dwelling automatic fire sprinkler systems. An automatic residential fire sprinkler system may be installed in one and two-family dwellings. (k) Chapter 11 of the International Residential Code is hereby deleted in its entirety. (l) Section G2417.4.1 of the International Residential Code is hereby amended as follows: G2417.4.1 (406.4.1) Test pressure. Test pressure shall be not less than 20 psig for a test duration of not less than 20 minutes. (m) Section G2417.4.2 of the International Residential Code is hereby amended as follows: G2417.4.2 (406.4.2) Test duration. Test pressure shall be not less than 20 psig for a test duration of not less than 20 minutes. (n) Section G2427.9.1 of the International Residential Code is hereby enacted as follows: G2427.9.1 Limestone filter required. All high-efficiency gas-fired appliances that produce condensate in a direct vent will pass that drainage through an approved limestone filter prior to discharge into the sanitary sewer. (o) Section P2603.1 of the International Residential Code is hereby amended as follows: P2603.5.1 Sewer depth. Building sewers that connect to private sewage disposal systems shall be not less than 30 inches (mm) below finished grade at the point of septic tank connection. Building sewers shall not be less than 30 inches (mm) below grade. (p) Section P2911.1 of the International Residential Code is hereby amended as follows: P2911.1 Prohibited. On-site non-potable water reuse systems are prohibited without special specific approval from the Utilities Director and the building official. (q) Section P3009 of the International Residential Code is hereby amended as follows: P3009 Greywater soil absorption systems. Greywater soil absorption systems are prohibited.
(Ord. 2485 §21, 2025)
Ask a question about Brighton law
Corpus searches the Brighton sections it holds and shows the ones that match, with their citations. Free, no sign-in.