Sec. 15-6-30. - Amendments to the International Building Code.
(a) International Building Code Section 101.1 is hereby amended as follows: 101.1 Title. These regulations shall be known as the Building Code of the City of Brighton, hereinafter referred to as "this code." (b) Section 105.2 (Building) of the International Building Code is hereby amended by the deletion of No. 2 (Fences not over 7 feet (2134 mm) high). (c) Section 102.7 of the International Building Code is hereby enacted as follows: 102.7 Requirements not covered by this code. Requirements necessary for the strength, stability, or proper operation of an existing or proposed structure or site, or for the public safety, health, and general welfare, not specifically covered by this code, shall be determined by the Building Official. (d) Section 103.1 of the International Building Code is hereby amended as follows: 103.1 Creation of enforcement agency. The City of Brighton Building Division is hereby created, and the official in charge thereof shall be known as the building official. The function of the agency shall be the implementation, administration, and enforcement of the provisions of this code. (e) Section 1608.1 of the International Building Code is hereby amended as follows: 1608.1. General. Design snow loads shall be determined in accordance with Chapter 7 of ASCE 7, but the design roof load shall not be less than that determined by Section 1607. The uniform snow load shall not be less than 35 pounds per square foot. Previously reviewed and approved plans based on a 30 pounds per square foot uniform snow load are acceptable. (f) Section 1609.1 of the International Building Code is hereby amended as follows: 1609.1 Applications. Buildings, structures, and parts thereof shall be designed to withstand the minimum wind loads prescribed below or determined by Chapters 26 to 30 of ASCE 7. Decreases in wind loads shall not be made for the effect of shielding by other structures. Risk Category I: 101 MPH 100-year MRI Risk Category II: 107 MPH 100-year MRI Risk Category III: 114 MPH 100-year MRI Risk Category IV: 118 MPH 100-year MRI (g) Section 1612.3 of the International Building Code is hereby amended as follows: Section 1612.3 Establishment of flood hazard areas. To establish flood hazard areas, the applicable governing authority shall adopt a flood hazard map and supporting data. The flood hazard map shall include, at minimum, areas of special flood hazard as identified by the Federal Emergency Management Agency in an engineering report entitled "The Flood Insurance Study for the City of Brighton," dated December 2, 2021, as amended or revised with the accompanying Flood Insurance Rate Map (FIRM) and Flood Boundary and Floodway Map (FBFM) and related supporting data along with any revisions thereto. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. (h) Section 1613.1 of the International Building Code is hereby amended as follows: 1613.1. The seismic design category for all structures is B coefficient.
(Ord. 2485 §15, 2025)
Ask a question about Brighton law
Corpus searches the Brighton sections it holds and shows the ones that match, with their citations. Free, no sign-in.