§ 5.04 — Building Design
Municipal Code of the City of Brighton, Colorado (Codified through Ordinance No. 2508, adopted June 16, 2026. (Supp. No. 26, Update 2)) · Brighton Land Use and Development Code § 5.04
Corpus is an independent public-information project, not the official City of Brighton website. Stable reference: corpuslaw.us/code/ca033697-49ea-4ed4-a8c5-c8e43f39b665
5.04 - Building Design
A. Design Objectives. Building design refines the scale and form of buildings beyond basic height, setback and lot coverage standards. Design breaks down the building volume into smaller-scale masses, and it adds depth, texture and variation to surfaces, in a manner that improves the relationship of buildings to the lot, to adjacent lots and buildings, and to the streetscape. The following design objectives shall be used in applying the building design standards in this section. 1. Relate buildings to public realm and streetscape in a consistent manner and create a rhythm of mass to voids from facades along the block face. 2. Arrange buildings in a way that creates meaningful outdoor spaces on the site, with building designs that define and activate these spaces. 3. Blend a variety of building sizes and types and create compatible transitions between adjacent buildings of different scale by mimicking similar massing and proportions of adjacent development with step-backs and secondary masses. 4. Break down larger masses with human scale design features, particularly on facades along streetscapes and active open spaces, or nearest adjacent lots. 5. Encourage unique architectural expression, and promote the use of key details and design characteristics inherent in the chosen style for the building. 6. Promote enduring investments with the application of durable, quality materials. B. Building Design Standards. Table 5-7, Building Design Standards provides standards for massing and facade design to meet the design objectives. Subsections following the table provide specific design strategies and techniques to be used in meeting these standards. Table 5-7: Building Design Standards Design Detail | Building Type | Detached House (all), Duplex, and Multi-Unit House | Row House, Apartment (all), Live/Work Minimum window and door openings per story (includes decorative trim, molding and casing) | [image omitted; see the official code] | Front - 20% 1 st story; 10% upper stories Side - 8% Street-side: 15% Rear: 10% | Front - 20% 1 st story; 10% upper stories Side - 8% Street-side: 15% Rear: 10% Maximum wall plane, with no minimum modulation | [image omitted; see the official code] | 600 s.f., or 35 linear feet | 800 square feet, or 50 linear feet Maximum wall plane, with at least 20% modulation | [image omitted; see the official code] | 601 - 900 s.f., or 36 - 50 linear feet | 901 - 1,200 square feet, or 51 - 70 linear feet Maximum building elevation without minimum 4' off-set on at least 25% of facade | [image omitted; see the official code] | 901 + s.f. or 51 + linear feet | 1,201 + s.f. or 71+ linear feet Maximum roof plane limits without offsets, dormers or gables | [image omitted; see the official code] | 800 s.f. or 40 linear feet | 1,000 s.f. or 50 linear feet C. Front Entry Features. Front entry features create a human-scale relationship of buildings to the street, provide opportunities for subtle variations in design between buildings along the streetscape, and can help create compatible relationships between buildings of different scale or size. The following entry features standards and design techniques shall be used where entry features are required by Frontage Types in Table 5-5, and are recommended on frontage types where they are optional to achieve the design objectives of this Section and to meet the standards of Table 5-7, Building Design Standards. > Table 5-8: Front Entry Features Design Element | Width | Depth | Details & Ornamentation Porch | At least 50% of front facade or 20', whichever is less | 8' - 12' | Decorative railing or wall 2.5' to 4' high along at least 50% of the perimeter. If not roofed, a canopy, pediment, transom windows, enlarged trim and molding or other similar accents accompany the door. Stoop | 8' - 20' | 6' - 10' | Ornamental features accent the door, including decorative side railings, canopy, pediment, transom windows, enlarged trim and molding, or other similar accents that emphasize the door over other facade features. Entry Court | 12' +, but never more than 50% of facade | 10' - 30' | Recessed entry within the building footprint. Decorative wall or railing, no higher than between 2.5' and 6' high along at least 50% of the opening. General Design | • All entry features shall have a sidewalk of at least 4 feet wide directly connecting the entry feature to the public sidewalk or street • All entry features shall be integrated into the overall building design including compatible materials, roof forms, and architectural style and details. [image omitted; see the official code] Figure 5-5 Front Entry Features—Types The porch, stoop and entry court are three distinct types of entry features that create active, social spaces and human-scale details on the residential frontages. Spaces with a minimum width (A) and depth (B) specified in table 5-8 provide usable social spaces, activate the streetscape and frontage, and contribute to the massing and modulation required by the building design standards. 1. Variations in the front entry features should create diversity among adjacent buildings along a block face, so that the same or similar entry feature does not occur within two buildings on either side. Variations should include combinations of at least two of the following changes: a. Different types: such as, porch, stoop, or entry court; b. Different roof styles: such as gable, hip, shed, flat, arched, or no roof; c. Different locations and extent: such as centered, shifted, wrapped and half or full; and/or d. Different ornamentation or architectural styles that lead to distinct qualities within a similar scale or pattern. [image omitted; see the official code] Figure 5-6 Primary Entry Feature—Variations Options for primary entry features help avoid repetition building designs along a streetscape and subtle variations allow consistent, human-scale relationships between buildings and streetscapes. Various combinations of types, location and extent, and design options (far beyond those even in this illustration) lead to unending diversity in frontages within a consistent scale and pattern. 2. Entry features meeting these design requirement may encroach up to 10 feet in front of the required front building line, but never closer than 5 feet to a public or common property line, provided they are unenclosed on all sides that project into the setback (no windows, screens or full walls). [image omitted; see the official code] Figure 5-7 Primary Entry Feature—Encroachments Front entry features meeting the standards of this section create social spaces that help activate streetscapes, and create a variety of human-scale details along blocks. These features may encroach into the front setback to improve the frontages along blocks. 3. Any building with more than 150 feet of front facade, or any side permitted greater than 200 feet and permitted within 20 feet of the street, shall have 1 entry feature for every 100 linear feet of building frontage on the street. [image omitted; see the official code] | Figure 5-8 Primary Entry Feature—Large Buildings Front entry features should be more frequently located on larger buildings with wall planes in close proximity to the street. This breaks up the building massing and activates the streetscape. D. Massing & Modulation. Massing and modulation refers to the use of form and materials to break facades into smaller components and to relate buildings to the surrounding spaces. The following techniques should be to achieve the design objectives of this section and to meet the standards of Table 5-7, Building Design Standards: 1. | Step the height of the building mass, off-set secondary masses from main masses, and divide larger facades into smaller components with projections, recesses, and material changes and ornamentation. | [image omitted; see the official code] 2. | Modulation of larger wall planes should occur with features that create at least 2' of projection or relief, such as bay windows, chimneys, balconies and other similar projections and recesses. 3. | When elevations become large and out of scale with the building or site, off-sets of at least 4' should occur to create main masses and secondary masses or to differentiate stories. 4. | Articulate larger roof planes by stepping the roof at least 2 feet, using different material or ornamental details on wall planes within gables, using dormers with windows, and using prominent overhangs of at least 3 feet with decorative trim. These elements should occur so that at least 25% of the roof plane is differentiated as a distinct mass. 5. | Provide porches, balconies and covered entries, and windows that accompany off-sets or projections in the facade, and relate the building to meaningful and human-scale outdoor spaces. 6. | Differentiate stories, roofs, or other masses and components of the facade with prominent trim materials and incorporation of material changes on different modules of the building. E. | Windows & Doors. The location, extent, pattern and proportions of windows and doors creates permeable facades that relate to and activate spaces. The following techniques should be used to achieve the Design Objectives of this section and the standards of Table 5-7, Building Design Standards: 1. | Emphasize a hierarchy of doors with different levels of ornamentation and details, particularly where multi-unit buildings are designed to be compatible with adjacent detached houses. Figure 5-9 Massing, Modulation, Windows and Doors A variety of design techniques can be used to meet the standards of Table 5-7: Building Design Standards. These techniques break down the components of buildings to smaller and human-scale details, and help relate buildings to the streetscape and to adjacent property. These techniques are particularly important for larger buildings or where a variety of building types are permitted in close proximity. 2. Provide transparency with the location, pattern and proportions of windows and doors, and create relationships to surrounding public, common or social spaces. 3. Locate windows strategically in relation to privacy concerns in adjacent spaces and buildings, but maintain consistent exterior patterns and recall that window treatments are a better adaptable and user-controlled strategy than simply no windows at all. 4. Use windows and doors designed to create depth, texture and shadows on the facade - openings that have a deep recess (at least 3 inches); have projecting trim and casements (at least 1 inch off the facade and 4 inches wide); use multiple panes within openings; or have similar features, will break up facades and provide more visual interest. 5. Incorporate visually significant windows and doors (size, orientation, and ornamentation) as points of emphasis at key locations on the facade. F. Materials. Building materials with texture and patterns create visual interest and signify quality construction and detailing. The following techniques should be used to achieve the Design Objectives of this section and the standards of Table 5-7, Building Design Standards: 1. Use natural materials such as painted or natural finish wood siding (horizontal lap, tongue-and-groove, board and batten or vertical), brick, stone, stucco, ceramic or terra cotta tile. Synthetic alternates to these natural materials may be used if manufacturer specifications and/or precedents for application demonstrate that it will perform equally or better than the principal materials in terms of maintenance, design and aesthetic goals. 2. Coordinate changes in color and materials in association changes in massing and modulation of the building. 3. Use changes in color or materials to differentiate the ground floor from upper floors and the main body of the building from the top or roof-structure, particularly on buildings 3 stories or more. 4. In multi-building projects, use subtle variations in building materials and colors on different buildings, within a consistent palette of materials and colors. G. Variations of Buildings. All projects involving three or more buildings shall provide variations in the elevation from the two buildings on either side, and the three buildings on the opposite side, with at least two of the following: 1. Variations in the front entry features as indicated in 5.04.C.1; 2. Variations in the facade massing and composition, including modulation, window types and placement, materials and material changes, details and ornamentation, or placement of garages in association with Frontage Type standards in Section 5.02.D, to the extent that the buildings have a distinct appearance; 3. Variations of the roof forms considering the type of roof, orientation of gables, or use of dormers; or 4. Variations of the model with distinctively different floor plans that lead to different massing. Mirror images of the same model and floor plan shall not count. 5. In the case of multi-unit buildings: a. For duplexes/multi-unit houses that are intended to mimic the scale and form of detached houses, a hierarchy of doors and entrances shall be used to create the appearance of a single building, and the variation shall apply between buildings. b. For row houses and similar buildings that are clearly designed for multiple units, subtle variations in the materials and entry features that differentiate each unit shall also apply. H. Accessory Dwelling Unit (ADU) Design Standards. 1. General Requirements. a. ADUs shall comply with the accessory dwelling uses Section 4.03 B.1 of this code and, except where specifically required herein, are not subject to Sections 5.03 Lot Open Space Design or Sections 5.04 A through G Building Design. b. ADUs are not Accessory Buildings nor subject to the requirements specific to Accessory Buildings - Residential in Section 5.02. c. Required building setbacks for ADUs shall be the same as those applicable to the principal building except the rear setback shall be 10 feet, or when attached to or within a detached garage accessed from an alley, the rear setback shall be 5 feet. In no case shall construction of an ADU decrease the minimum setbacks applicable to the principal building. d. An ADU shall be clearly subordinate to the principal building in terms of scale, location, and orientation. e. An ADU shall have its own exterior entrance, except an attached or internal ADU may share an exterior entrance with the principal building or an accessory building provided that each unit has a secure entry door at a common hallway and the common hallway leads directly to the exterior of the building. f. The exterior entrance leading into an ADU or into a common hallway serving an ADU shall have an entry that relates the ADU to its access point on the lot. g. Exterior stairways leading to an ADU entrance shall not exceed 1 story in height. h. ADUs shall not exceed 2 stories or 35 feet in height. i. ADUs shall be affixed to a permanent engineer-designed foundation. 2. A detached ADU shall: a. Be limited to an above-grade living floor area not exceeding the above-grade living floor area of the principal building and shall not exceed 1200 square feet; and b. If served by an alley, be accessed from the alley (the Director may allow access to the ADU from the side street on corner lots). 3. An ADU attached to the principal building shall: a. Be limited to an above-grade living floor area not exceeding the above-grade living floor area of the principal building and shall not exceed 1200 square feet; b. Comply with Section 5.04 of this code; and c. Without applying a higher standard than that in place for the principal building, be designed to maintain the architectural design, appearance, and character of the principal building, including similar massing, scale, and story height. 4. An ADU located within the principal building, such as within a basement, shall be limited to the spatial constraints of the principal building and shall not exceed the living floor area of the remainder of the principal building. 5. An ADU addition to or alteration within an existing accessory building shall comply with the requirements for a detached ADU, and the overall building shall not exceed 2 stories or 35 feet in height. I. Exceptions. The Director may approve exceptions to the building design standards where: 1. The requirement is not consistent with the particular architectural style of the building based on reputable resources documenting the style; 2. The requirement would make the building less compatible with designs or characteristics of other buildings or sites in the area; or 3. An alternative design equally or better meets the design objectives of this section. 4. In any case, the deviation is the minimum necessary to address the circumstance and does not negatively impact other design standards applicable to the building or site.
(Ord. No. 2405, § 11, 1-3-2023; Ord. No. 2475, §§ 7, 8, 6-17-2025; Ord. No. 2494, § 1, 2-3-2026)
Ask a question about Brighton law
Corpus searches the Brighton sections it holds and shows the ones that match, with their citations. Free, no sign-in.
