§ 6.02 — Non-residential Building Types
Municipal Code of the City of Brighton, Colorado (Codified through Ordinance No. 2508, adopted June 16, 2026. (Supp. No. 26, Update 2)) · Brighton Land Use and Development Code § 6.02
Corpus is an independent public-information project, not the official City of Brighton website. Stable reference: corpuslaw.us/code/827d7291-2da1-4b56-8864-f132933602c2
6.02 - Non-residential Building Types
A. Design Objective. The following building types are established to allow a range of non-residential buildings and create effective transitions within and between mixed-use, commercial and employment centers, and the neighborhoods they support. The building types provide distinctions based on typical uses, building footprints and massing, building placement and frontage designs. Table 6-1: Non-residential Building Type Descriptions & Design Objectives Small Commercial - Pad Site A small building similar to a Small Commercial / Mixed-use - Storefront, but on a larger lot that includes more space for access, circulation, landscape and buffers. Careful planning and site design can allow a series of these buildings to improve relationships with street scapes and be "liner buildings" for General Commercial or Large Commercial buildings, which may be set back from the public realm. | [image omitted; see the official code] General Commercial A building type designed to accommodate retail, commercial, service or office functions in a variety of formats and scales. Variations of this type are based on the scale and intensity of the use and subject to basic lot and setback standards of the zoning district. | [image omitted; see the official code] Large Commercial A building type designed to accommodate large-scale retail, commercial, service or office functions usually in a larger center or complex, and subject to basic lot and setback standards of the zoning district. Site design, building orientation, and lot access standards are arranged to accommodate the patterns and circulation necessary for these large buildings and strategically locate these larger parcels and buildings within that pattern. | [image omitted; see the official code] Lodging A building designed for commercial lodging at a variety of scales. Variations of this type are based on the number of rooms provided and are subject to basic lot and setback standards of the zoning district. | [image omitted; see the official code] General Industrial A building designed to accommodate light industrial or general industrial functions in a variety of formats, with a more utilitarian in design. Variations of this type are based on the scale and intensity of the activity, any specific functions for the intended use, and subject to basic lot and setback standards of the zoning district. | [image omitted; see the official code] Civic A building designed for a civic, institutional or public use, that emphasizes the public realm through building and open or civic space enhancements that create focal points. Variations include small civic buildings for integration into neighborhoods and mixed-use areas and prominent civic buildings often in more intense mixed-use centers, corridors or campus settings, with specific patterns and scale based on the functions for the intended use. | [image omitted; see the official code] Live/Work A building designed for a primary dwelling unit but has a secondary component - typically at the building frontage - designed for a commercial or occupational function by the resident. This building type is for transitions between neighborhoods and commercial centers or busier corridors or for nodes within neighborhoods or mixed-use areas. | [image omitted; see the official code] Small Commercial/Mixed-use - Storefront A building designed to accommodate small retail, commercial, service, office or limited manufacturing functions and particularly for uses with frequent pedestrian interaction. This building may have an accessory residential component in the rear or on upper stories. The small footprint, small lot, and design of the frontage for pedestrian and customer engagement allows this building type to integrate well in walkable and mixed-use contexts. This building is typically 1 to 3 stories and groupings of this building form the most pedestrian-scaled blocks of compact walkable places. | [image omitted; see the official code] Medium Commercial/Mixed-use A moderate-scale building designed to accommodate street-level retail, commercial, service, office or limited manufacturing functions, and upper level residential, office or commercial uses that compliment other uses on the site or in the immediate area. This building is typically 3 to 4 stories and takes up no more than ¼ block to maintain the compact scale and finer-grained patterns of walkable places. | [image omitted; see the official code] Large Commercial/Mixed-use A large-scale building designed to accommodate street-level retail or commercial use with frequent pedestrian interaction and upper level residential, office or commercial uses that provides a concentration of activity to support other uses in the district. This building is typically 4 to 5 stories and takes up no more than ½ block but may be larger in particular contexts where greater density or intensity supports broader planning goals. | [image omitted; see the official code] B. Building Types and Development Standards. The development standards for non-residential districts shall be based on the different building types permitted in each district, as specified in Table 6-2, Non-residential District Building Type & Development Standards. The Design Standards in Section 6.02 may further specify the design and location of each building type, based on its relationship to the public realm. Table 6-2: Non-residential District Building Type & Development Standards Eligible Zoning Districts | Building Types | Development Standards C-0 | C-1 | C-2 | C-3 | BP | DT | MU-NC | MU-CC | MU-R/EC | I-1 | I-2 | Lot Standards | Setbacks[4] | Building Height Size | Width | Max. Coverage | Front [1] | Interior Side Min. | Corner Side Min. | Rear Min. ■ | ■ | ■ | ■ | ■ | □ | □ | □ | □ | ■ | Small Commercial - Pad Site | 7K s.f. minimum | 75' + | 50% | 25' + | 10'/15' res | 25' | 15'/35' res' | 25'/2 stories □ | □ | ■ | ■ | ■ | □ | □ | ■ | General Commercial | 40K s.f. minimum | 100' + | 50% | 25' + | 10'/15' res | 25' | 15'/35' res' | 25'/2 stories □ | ■ | □ | □ | Large Commercial | 3 ac. + | 200' + | 50% | 25' + | 10'/25' res | 50' | 15'/35' res' | 40'/3 stories ■ | ■ | ■ | □ | □ | □ | Lodging | 40K s.f. minimum | 100' + | 50% | 25' + | 10'/25' res | 25' | 15'/35' res | 50'/4 stories ■ | ■ | General Industrial [5] | 1 ac. + | 125' + | 50% | 50' + | 10'/35' res | 50' | 15'/35' res' | 50' I-1 75' I-2 ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | Small Civic | 5K s.f. minimum | 50'—300' | 50% | 20'—50' | 25' | 25' | 25' | 35'/3 stories □ | ■ | ■ | ■ | ■ | ■ | ■ | Prominent Civic | 1 ac. minimum | 150' + | 50% | 20'—50' | 25' | 25' | 25' | 70'/6 stories □ | □ | □ | □ | □ | □ | ■ | ■ | ■ | Live/Work | 2K s.f. minimum | 18'—50' | 80% | 0'—25' | 5' | 10' | 20' | 40'/3 stories □ | □ | □ | □ | □ | ■ | ■ | ■ | ■ | Small Commercial/ Mixed - Use - Storefront | 2K s.f. minimum | 25'—100' | 90% | 0'—10' | 5'/0' if party wall | 10' [2] | 20' min./10' if alley | 40'/3 stories □ | □ | □ | ■ | □ | ■ | ■ | Medium Commercial/Mixed-Use | 10K s.f. minimum; up to 1/4 block max | 100'—200' | 90% | 0'—10' | 10/0' if party wall | 10' [2] | 20' min./10' if alley | 60'/5 stories [3] □ | □ | □ | ■ | Large Commercial/Mixed-Use | 50K s.f. minimum; up to ½ block max | 200'—400' | 90% | 0'—10' | 10'/0' if party wall | 10' [2] | 20' min./10' if alley | 60'/5 stories [3] ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | Accessory Buildings | See Section 6.02.D □ | □ | □ | □ | Row House | See Residential Building Type & Development standards in Article 5 □ | □ | □ | □ | Small Apartment | See Residential Building Type & Development standards in Article 5 □ | □ | □ | Medium Apartment | See Residential Building Type & Development standards in Article 5 □ | Large Apartment | See Residential Building Type & Development standards In Article 5 □ Building types are subject to specific design and location standards in Section 6.02.E. [1] Front setback requirements may be modified for a particular street or block, based on the Frontage Type Standards in Section 6.04. [2] Corner side setbacks for mixed-use buildings may be 0' to 10' if at least the first 30' of the building from the corner is designed to meet the frontage design standards of the primary facade. [3] Medium and Large commercial/mixed-use buildings may only exceed 5 stories/60', and up to 10 stories/110' through a planned district approval. [4] Buildings that require a certificate of occupancy shall be setback at least 250' from an oil/gas facility, and 25 feet from a well that has been plugged and abandoned. Buildings that do not require a certificate of occupancy shall be setback 150 feet from a tank battery or oil/gas well (unless plugged and abandoned). Lots abutting residential zoning or uses ("res") require additional side and rear setbacks. [5] Setbacks for industrial buildings may be averaged for two sides provided no building is less than 5' from the property line, or is attached only where there is four-hour rated construction. C. Dimension Exceptions. The following are exceptions to setback and building dimensions standards established in Table 6-2: Non-residential District Building Type & Development Standards. 1. Setback Encroachments. The following encroachments into the required setback are permitted, except in no case shall this authorize structures that violate the provisions of any easement. a. Any projections over public rights of way, or any similar area designed for pedestrian circulation, shall be at least 8 feet above the grade, and in no case within 2 feet of any curb for a street, through access drive or other area designed for vehicles. b. Structural projections such as bay windows, balconies, canopies, chimneys, eaves, cornices open fire escapes, egress wells, or other non-foundational overhangs or projections may extend up to 4 feet from the foundation and encroach into the setback, but no closer than 2 feet from any side lot line. This exception shall be limited to no more than 20% of the surface area of a building elevation. c. Unenclosed and unroofed decks or patios at or below the first floor elevation may extend into the rear or side setback up to 15 feet but no closer than 5 feet to any lot line. d. Ground-mounted mechanical equipment accessory to the building may be located in the side or rear setback provided that it extends no more than 6 feet from the principal building, no closer than 3 feet to the lot line, and is screened from public right-of-way by structures or landscape. These limitations do not apply to any utility structures otherwise authorized to be located according to easements or in the right-of-way, which shall follow the location and design standards of those specific authorizations. e. Any other accessory use or structure within the setback, not specified in Section 6.02.D, shall have a setback of at least 1/3 its height from the property line. 2. Height Exceptions. The following are exceptions to the height limits in Table 6-2: a. Building elements integral to the design and construction of the building, such as parapet walls, false mansards or other design elements essential to a quality appearance of the building may extend up to 6 feet above the roof deck. b. Architectural features such as belfries, chimneys, ornamental towers and spires and similar accessory features that a minimal part of the building footprint, massing and volume, may extend up to 50% above the actual building height. c. Functional and mechanical equipment such as elevator bulkheads, cooling towers, smoke stacks, roof vents or other equipment may be built up to their necessary height in accordance with building codes. D. Accessory Buildings—Non-residential. Accessory buildings shall be permitted in association with and on the same lot as a principal building and are subject to the following additional limitations. 1. Generally. All accessory buildings shall be at least 10 feet from the principal building, unless a lesser distance is specified by applicable building codes. 2. Small Sheds. Accessory buildings 120 square feet or less and less than 12 feet tall shall be limited to: a. 1 per lot or 1 per each 5,000 square feet of lot, whichever is more, up to a maximum of 3; b. Be located behind the front building line of the principal building. 3. Detached Building—Non-residential. In any non-residential district, a detached accessory building or roofed structure over 120 square feet or over 12 feet tall shall meet the following standards: a. No more than 1 per lot or 1 per each 10,000 square feet of lot, whichever is more, up to a maximum of 4. b. Located at least 30 feet from the front lot line or behind the front building line of the principal building, whichever is greater, except that canopies for Vehicle - Fueling Station and Vehicle - Travel Center or other covered parking area may be located in front of the front building line provided the canopy overhang structure is at least 30 feet from any lot line and no more than 20 feet tall. c. Maximum height of 2 stories, up to 24 feet, but no higher than the principal building. d. Maximum of 1,000 square feet or 50% of the principal building footprint, whichever is greater, except that canopies for Vehicle - Fueling Station and Vehicle - Travel Center may be sized to cover all fueling dispensers, and except that Public/Civic Uses listed in Section 4.02, Table 4-2 without a principal structure may be up to 5,000 square feet. e. Any portion of the building or structure potentially visible from the street or other public areas shall use materials, colors, scale and forms (roofs and massing), and details that are compatible with the principal structure, or otherwise be screened according to Article 8. f. Any building or structure larger than this shall be treated as a second principal building and meet all lot and building design standards applicable to principal buildings. g. Accessory buildings shall not be located within an easement area. 4. Detached Building—Civic Uses and Open Space. Accessory buildings for permitted institutional uses or public and common open spaces are permitted subject to the following: a. Setback. 30 feet from the front lot line or behind the front building line of the principal building, whichever is greater; 5 feet from the rear or side property line. b. Area. 5,000 square feet maximum. c. Height. 25', but 1' of additional height for each 2 feet of additional setback. d. Number. 1 per every 3 acres. E. Location Criteria for Limited Building Types. Buildings indicated as limited application in Table 6-2, Non-residential Building Standards, (□) shall only be permitted in the following locations within the applicable zoning districts, unless more specifically located through a planned district. 1. In the C-O, C-1, C-2, C-3 and BP zoning districts, the limited building types should only be permitted to front on streets or through access drives that promote a high level of pedestrian activity based on the Pedestrian/Mixed-Use, Avenue and Boulevard street types. Additionally, in any area where the City has invested in or documented plans to invest in improved streetscapes, mixed-use building types and street-front or terrace frontage types may be required. 2. In the DT, MU-NC, MU-CC, and MU R/EC zoning districts, the non-residential building types should only be used on secondary blocks or streets, through access drives, or similar locations that are otherwise removed from the walkable streets or arterial streets. In these circumstances, these buildings should be used for a key anchor or support uses that are important to the vitality of the district but cannot easily conform to more compact, walkable building formats. Alternatively, where these buildings are located on pedestrian-oriented streets, they should be buffered by liner buildings and smaller mixed-use or commercial buildings that better address the streetscape or hide large parking areas. 3. The residential building types (row house and small, medium, and large apartments) should be located on blocks and streets that create transitions between the mixed-use or commercial areas and neighborhoods.
(Ord. No. 2405, §§ 15—18, 1-3-2023; Ord. No. 2495, § 2, 2-3-2026)
Ask a question about Brighton law
Corpus searches the Brighton sections it holds and shows the ones that match, with their citations. Free, no sign-in.
