8.06 - Outdoor Lighting
A. Design Objectives. Exterior lighting of sites and buildings shall meet the following design objectives: 1. Provide safety and security in publicly accessible areas. 2. Create comfort and ambiance with softer and warmer lighting in gathering spaces, social places, and pedestrian-oriented streetscapes. 3. Accent the architectural features buildings, gateways or other portions of sites visible from the streetscape or other public spaces. 4. Design the appropriate scale of light considering pedestrian-oriented or vehicle-oriented portions of sites. 5. Limit glare or other impacts that sight lighting could have on adjacent sites with the appropriate design, location and type of fixture, and based on the context of the area. 6. Reinforce the unique character of particular areas with the types and style of lighting fixtures. 7. Develop energy efficient lighting strategies in balance with other site lighting objectives. B. Mounting Height. All exterior lighting shall be limited to the mounting heights specified in the following table: Table 8-9: Maximum Lighting Mounting Height Driveways and Parking Areas | • 35' in non-residential districts. • 24' in all other districts; or within 30' of any street; or any light within 100' of a residential use or residentially zoned property. Pedestrian Walkways, Plazas or Courtyards, and Pedestrian-oriented Streetscapes | • 16' Facade Lights | • Below the eave or cornice line, provided the light is directed downward or otherwise designed and located to limit up lighting beyond the facade. Other Site Lighting | • 12' non-residential; • 7' residential Building Mounted Security Lights | • May be mounted at heights required to provide adequate security provided all efforts be made to mitigate off-site impacts including dimmers, timers, sensors, shields or other technology. General | • All light poles shall be setback from the property at least 3', and at least 50% of the height, whichever is greater. Outdoor sports and recreation facilities | Lights for outdoor sports and recreation facilities are not limited by this section, but shall be subject to site plan review as a part of the proposed project. Generally lights shall: • Not exceed 80' • Shall be setback from the property line at least 1' for every 2' of height or 1' for every 1' of height abutting residentially zoned property. • Shall not exceed 2 foot-candles illumination at the property line. • No lighting after 11 PM. C. Shielding. Except for ornamental lights below 2,400 lumens, all exterior fixtures shall be fully shielded and installed so that the direct illumination shall be confined to the property boundaries of the source. Table 8-10 Required Shielding Wattage or Mounting Height | Shield Type Full Cutoffa | Cutoffb | Semi-cutoffc All lights mounted above 25'; or All lights above 5,000 lumens | Required | — All lights between 2,400 and 5,000 lumens and mounted below 25'. | Permitted | Required All lights below 2,400 lumens and mounted between 12' and 25'' | Permitted | Permitted | Required All lights less than 2,400 lumens and mounted less than 12' | No shielding is required; all shielding types permitted. a. Full cutoff fixtures emit 0% of its light above 90 degrees and 10% above 80% from horizontal. b. ;hg;Cutoff fixtures emit no more than 2.5% of its light above 90 degrees and 10% of its light above 80% from horizontal. c. ;hg;Semi-cutoff fixtures emit no more than 5% of its light above 90% and 20% of its light above 80 degrees. [image omitted; see the official code] Figure 8-4 Light Shielding Table 8-10 permits different types of light fixture shielding or "cutoff" based on the brightness of the light source and mounting heights, to minimize potential light glare on streetscapes or adjacent property. Figure 8-4 presents how fixture cutoff is measured in order to best meet the design objectives of this section. D. General Standards. In addition to the mounting height and shielding standards, exterior site lighting shall meet the following general standards: 1. All lighting shall be designed and located to not provide direct light or glare onto any adjacent property or any public right-of-way, other than building mounted lighting on street-front buildings which may be designed in a manner that impacts only public sidewalks or other pedestrian oriented places in the right-of-way. [See Section 4.06, District Performance Standards for lighting standards at the perimeter of property for non-residential districts.] 2. Exterior building, site and parking lighting for any building over 50,000 square feet, any parking area over 150 spaces, or any non-residential use abutting residential uses or zoning districts shall be equipped with dimming interfaces. a. All lighting for parking lots and surrounding areas shall be reduced to a level sufficient for security purposes only within one hour after closing. b. All other exterior site or building lighting shall be reduced to a level sufficient for security purposes only between 10 P.M. and 6 A.M. c. Dimming shall be at least 50% of full operational levels. 3. All facade lighting and other externally illuminating lights shall use shielded, directional fixtures, designed and located to minimize uplighting and glare. Decorative lighting, such as lanterns and wall sconces, which may be allowed as long as the fixtures, do not exceed 2,400 lumens and do not emit light directly upward. 4. The style of light standards and fixtures shall be consistent with the style and character of architecture proposed on the site and building. 5. Under-canopy lighting, such as fuel stations or similar canopies, shall have flush-mount, flat lens light fixtures. 6. All exterior lighting of the site, buildings or signs shall have underground power service. 7. A lighting plan shall show the location, mounting heights, fixture types and lighting level for all lights. A photometric plan prepared by a qualified professional may be required by the Director for large-scale uses or where certain compatibility and adjacent issues exist.
Ask a question about Brighton law
Corpus searches the Brighton sections it holds and shows the ones that match, with their citations. Free, no sign-in.