For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 9.05 — Standards for All Signs

Municipal Code of the City of Brighton, Colorado (Codified through Ordinance No. 2508, adopted June 16, 2026. (Supp. No. 26, Update 2)) · Brighton Land Use and Development Code § 9.05

Corpus is an independent public-information project, not the official City of Brighton website. Stable reference: corpuslaw.us/code/5e64e527-77c4-408a-86e2-22eaff12ac81

9.05 - Standards for All Signs

A. Sign Design. 1. In general, signs shall have mutually unifying elements which may include uniformity in materials, color, size, height, letter style, sign type, shape, lighting, location on buildings, and design motif. 2. Materials and textures of signs shall be compatible with the architectural character of the site and building. Supporting sign structures of freestanding signs shall match the primary finish and colors of the associated building(s). 3. Where possible, freestanding pole and monument signs shall integrate tenant signs into a single sign structure. 4. The electronic message area portion of a monument sign shall be integrated into the design of the monument sign. Such electronic message portions of a monument sign shall not be an add-on feature but rather must be fully integrated into the sign design. The entire sign must be compatible with the site design and/or building architecture. 5. Wayfinding and directional signage systems shall be of a unified graphical system. Such signage shall be placed in consistent locations near site entries, key points on the internal automobile and pedestrian circulation system, building entries, seating areas, and sidewalk intersections. B. Sign Construction and Installation. 1. Except for flags, window signs and temporary signs conforming to the requirements of this Section, all signs shall be constructed of high quality durable materials and shall be permanently attached to the ground, a building, or another structure by direct attachment to a rigid wall, frame, or structure. No plywood signs shall be permitted. 2. All permanent signs and all components, including sign structures and sign faces, shall be installed in compliance with the adopted building and electrical codes of the City. a. All professional installations of signs shall require a contractor's license from the City prior to any installation. b. All electrical work for the construction and/or operation of a sign shall be performed in accordance with the Electrical Code as adopted by the City and shall be subject to inspection by the City for compliance therewith. c. Signs shall be located to maintain horizontal and vertical clearance of all overhead electrical conductors in accordance with adopted electrical code specifications, depending on voltages concerned. However, in no case shall a sign be installed closer than 48 inches horizontally or vertically from any conductor or public utility guy wire, or as recommended by the local public utility company. d. Every electric sign shall have an approved Underwriters' Laboratories label on it, or all wiring approved by the State electrical inspector, and all wiring connected to the sign shall comply with all provisions of the applicable regulations of the City relating to electrical installations. e. No sign or sign structure shall be installed that impedes pedestrian or vehicular movement, or erected in a location that obstructs or interferes with motor vehicle traffic or traffic-control devices, or obstructs clear vision in any direction from any street intersection or driveway. f. No sign or sign structure shall be installed that obstructs access to or impedes operation of any fire escape, downspout, window, door, stairway, ladder or opening intended to provide light, air, ingress or egress for any building or structure as may be required by law. g. Signs should not be placed in locations that obscure architectural features such as pilasters, arches, windows, cornices, etc. h. No sign or sign structure shall be installed which is structurally unsafe. 1. All permanent freestanding pole signs shall have self-supporting structures erected on, or permanently attached to, concrete foundations. C. Sign Maintenance. 1. All signs, both currently existing and constructed in the future, and all parts and components shall be maintained in a safe condition in compliance with all building and electrical codes, and in conformance with this Article. a. All signs, including sign structures and sign faces, shall be maintained in good repair at all times and shall not constitute a hazard to safety, health or public welfare by reason of inadequate maintenance or deterioration. For the purposes of this Article, good repair shall mean that there are no loose, broken, torn or severely weathered or faded portions of the sign structure or sign face. b. The owner of any sign regulated by this Article shall be required to keep signs and supporting hardware structurally safe, clean, free of visible defects, including graffiti, and functioning properly at all times. Exposed surfaces shall be clean and painted if paint is required. Defective parts shall be replaced. Repairs to signs shall be equal to or better in quality of materials and design than the original sign. c. All electronic message centers shall be equipped with a malfunction display and the ability to automatically shut off if a malfunction occurs. An electronic message center under repair shall be shut off. d. Bus bench signs shall be maintained in a safe and clean condition at all times. Damaged or disfigured benches shall be repaired or replaced immediately upon notification by the City of damage or disfigurement, or the bench will be removed. The area around and under a bus bench must be kept clear of ice, snow, mud, trash and weeds. 2. All signs or any part of a sign which is broken or damaged or which is not reasonably maintained such as to present a nuisance, hazard or potential hazard, including any required landscaping, shall be repaired or removed by the sign owner such that the sign no longer is a nuisance or endangers public health and/or safety. If the sign owner fails or refuses to repair or remove the unsafe sign, the sign shall be deemed a nuisance and the City may abate the nuisance as provided in Section 8-24, Abatement of Nuisances, of the Brighton Municipal Code. D. Lighting. Signs may be illuminated by external or internal means, unless as otherwise specifically provided in this Article, subject to the following standards: 1. The brightness and intensity shall not be greater than necessary to meet reasonable needs of the business or use served; 2. Light sources shall be shielded, shaded or hooded to direct the light inward and downward onto the sign and away from all adjacent buildings and streets; 3. The lighting shall not create excessive glare to pedestrians and/or motorists, and will not obstruct traffic control or any other public informational signs; 4. Electrical supply to illuminated freestanding pole or monument signs shall be underground; and 5. An electrical permit may be required per the electrical code for signs that are illuminated. 6. When commercial areas are adjacent to residential areas, the use of illuminated signs may be restricted at the discretion of the Director.

Ask a question about Brighton law

Corpus searches the Brighton sections it holds and shows the ones that match, with their citations. Free, no sign-in.